Bosch Appliances 25/32kW, 18/25, 12/18 Safety Precautions, Installation Regulations

Page 4

SAFETY &

REGULATIONS

SAFETY PRECAUTIONS

OIL SMELLS, LEAKS OR FUMES FROM THE APPLIANCE:

Extinguish any naked flames.

Isolate the electrical supply.

Isolate the fuel supply to the boiler.

Rectify fault.

HEALTH & SAFETY:

The appliance contains no asbestos and no substances have been used in the construction process that contravene the COSHH Regulations (Control of Substances Hazardous to Health Regulations 1988). Where applicable, the CE mark indicates compliance with relative EU Directives.

COMBUSTIBLE AND CORROSIVE MATERIALS:

Do not store or use any combustible materials (paper, thinners, paints etc.) inside or within the vicinity of the appliance.

The combustion air must be kept clear of chemically aggressive substances which can corrode the appliance and invalidate any warranty.

FITTING & MODIFICATIONS:

Fitting the appliance and any controls to the appliance may only be carried out by a competent engineer in accordance with these instructions and the relevant Installation Regulations.

Flue systems must not be modified in any way other than as described in the fitting instructions. Any misuse or unauthorised modifications to the appliance, flue or associated components and systems could invalidate the warranty. The manufacturer accepts no liability arising from any such actions, excluding statutory rights.

SERVICING:

Advise the user to have the system regularly serviced by a competent, qualified engineer (such as OFTEC registered personnel) using approved spares, to help maintain the economy, safety and reliability of the appliance.

INSTALLATION REGULATIONS

Failure to install appliances correctly could lead to prosecution.

The appliance should be installed by a competent person. The person installing the appliance should be aware of the Health and Safety at Work Act and take appropriate action to ensure that the regulations are adhered to. In order to give optimum efficiency and trouble free operation the appliance must be commissioned by a qualified OFTEC engineer.

The compliance with a British Standard does not, in itself, confer immunity from legal obligations. In particular the installation of this appliance must be in accordance with the relevant requirements of the following British Standards and regulations in respect of the safe installation of equipment:

BS 5410: part 1: Code of practice for Oil Fired Boilers.

BS 799: part 5: Specification for Oil Storage Tanks.

BS 7593: Code of Practice for treatment of water in domestic hot water central heating systems.

B S 5449: part 1: Specification for forced circulation hot water central heating for domestic premises.

BS 5955: part 8: Specification for the installation of thermoplastic pipes and associated fittings for use in domestic hot and cold water services and heating systems.

BS 7291: Thermoplastic pipes and associated fittings for hot and cold water for domestic purposes and heating installations in buildings.

BS 7074: part 1: Application, selection and installation of expansion vessels and ancillary equipment for sealed water systems.

BS 7671: IEE Wiring Regulations, current edition.

BS 1362: Specification for general purpose fuse links for domestic and similar purposes.

The Building Regulations Part J and L1 England and Wales; Part F and Part J Section III Scotland; Part L and Part F Northern Ireland.

Local water company bye-laws.

The Control of Pollution (Oil) Regulations. OFTEC Standards.

Where no specific instruction is given, reference should be made to the relevant codes of practice.

3

SAFETY PRECAUTIONS

& INSTALLATION REGULATIONS

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR HEATSLAVE EXTERNAL 12/18-18/25-25/32 8 716 113 389b (09/07)

Image 4
Contents Greenstar Heatslave External 12/18, 18/25, 25/32kW Installation & Servicing Instructions Installation & Servicing InstructionsContents Safety Precautions Installation RegulationsSafety Precautions Installation Regulations OIL SMELLS, Leaks or Fumes from the ApplianceGeneral Information General InformationStandard Package Technical Data Technical DataDescription BSPLayout & Components Layout & ComponentsCleaning Primary Systems Cleaning Primary SystemsMains Supplies Mains SuppliesMains Water Expansion Vessel Electric SupplyOIL Supply OIL SupplyG J HeadWater Systems & Pipework Water Systems & PipeworkSHOWERS/BIDETS Filling Primary Sealed SystemsDomestic HOT Water Condensate Pressure Relief Pipework Condensate Pressure Relief PipeworkCondensate Pipework Pressure Relief PipeworkBoiler Location Clearances Boiler LocationClearances FrontCabinet Mounted LOW Level Flue Terminal Positions Cabinet Mounted LOW Level Flue Terminal PositionsTerminal Position High Level Flue Terminal PositionsHigh Level Flue Terminal PositionsBalanced External Oilfit Flue Options Balanced External OilfitFlue Options AC DHorizontal Flue Options Cabinet Mounted BalancedBalanced Flue Options Unpacking the Boiler Lifting and Carrying PrecautionsUnpacking the Boiler Pipework & Flue Positions SafetyPipework & Flue Positions Boiler Installation Boiler InstallationFlue Installation Flue InstallationInstallation Notes Combustion Chamber Combustion ChamberHor Plan sectional view Hook the retainer J over the end two bafflesPipework Connections Pipework ConnectionsWater Connections OIL Supply ConnectionsCondensate Connection Pressure Relief ConnectionOIL Burner & Pump OIL Burner & PumpOIL Burner OIL PumpRefitting Components Refitting ComponentsPlug burner lead E into control box F Mains Programmer External ElectricsBoard ElectricsBr Brown Blue Green/YellowRed WhitePRE-COMMISSIONING PRE-COMMISSIONING Checks ApplianceChecks Appliance Filling the System Filling the SystemStarting the Appliance Starting the ApplianceSafely dispose of the container/discharge Pressure adjustment Vacuum gauge port 25/32 Boiler lockout indicator onBleed & pressure gauge port Holder with oilBurner should be OFF and the circulating pump on Central heating Open all radiator valves Set the room thermostat to minimumWater Treatment Water TreatmentPump and all radiators Finishing Commissioning Finishing CommissioningAppliance Inspection and Service Inspection and ServiceRoutine servicing Loosen clip D to detach air ductClean the Burner 3.0mm Clean both sides of the fan impellerThoroughly clean any deposits Any debris and clean if necessaryFront 50 80EH 11.5 18.655 80EH 12.0 22.2Short Parts List 12/18 Short Parts List 12/18Auto reset High Limit thermostat Part Number 8 716 107 640 Burner SterlingShort Parts List 18/25 Short Parts List 18/25Manifold access cover seal Short Parts List 25/32 Short Parts List 25/32Fault Finding Fault FindingProblem Cause Remedy Faulty Boiler OperationNoisy operation Pump noise from air in pump or OIL SmellsBase of the control box before replacing any components Neutral N and the pin, wire orMeasure all 230V tests between 535 SE/LD RDB Fault Finding Control BOX Logic forSchematic ElectricalOIL Boiler Combustion Record Service 1 Date General checks Excellence Comes AS Standard

25/32kW, 12/18, 18/25 specifications

Bosch Appliances has carved out a reputation for engineering high-performance heating solutions, particularly with their range of heating systems including the 18/25, 12/18, and 25/32 kW models. These systems are designed to meet the diverse needs of residential and commercial spaces while maintaining energy efficiency and sustainability.

The Bosch 18/25 kW model excels in providing an optimal heating solution for medium to large residential properties. It is equipped with a highly efficient condensing boiler that extracts additional heat from flue gases, achieving significant energy savings. The built-in, user-friendly interface allows for easy programming and monitoring, which maximizes user convenience.

The 12/18 kW model provides a versatile opportunity for smaller homes or apartments. Its compact design ensures that it fits seamlessly into tighter spaces without sacrificing performance. The unit operates quietly, making it an excellent choice for residential areas where noise can be a concern. Additionally, it features the latest modulation technology, optimizing energy usage and maintaining consistent temperatures.

Finally, the 25/32 kW model is ideal for larger installations, offering robust performance even in high-demand scenarios. This model benefits from advanced heating management systems that enable intelligent control of heating zones, ensuring efficiency and comfort throughout the property. With its enhanced energy rating, the 25/32 kW model significantly reduces the carbon footprint, aligning with modern sustainability goals.

Across the board, Bosch Appliances integrates advanced technologies such as intelligent diagnostics, smart home compatibility, and eco-friendly materials. All models are constructed with durability in mind, featuring corrosion-resistant heat exchangers and high-quality components designed for longevity.

The customer-focused features, including comprehensive warranty packages and responsive customer service, further exemplify Bosch's commitment to quality. Overall, Bosch Appliances 18/25, 12/18, and 25/32 kW heating systems stand out for their innovative technology, efficient performance, and reliability, making them an excellent choice for those looking to upgrade their heating solutions.