Bosch Appliances instruction manual Greenstar Heatslave External 12/18, 18/25, 25/32kW

Page 1

GREENSTAR HEATSLAVE EXTERNAL 12/18, 18/25, 25/32kW

FLOOR STANDING EXTERNAL OIL FIRED CONDENSING COMBINATION BOILER USING BALANCED FLUE SYSTEM

FOR OPEN VENT AND SEALED CENTRAL HEATING SYSTEMS WITH DOMESTIC MAINS FED HOT WATER

THE APPLIANCE IS FOR USE WITH KEROSENE ( 28 SECOND

OIL) ONLY

GB

INSTRUCTION MANUAL

INSTALLATION COMMISSIONING & SERVICING

Image 1
Contents Greenstar Heatslave External 12/18, 18/25, 25/32kW Installation & Servicing Instructions Installation & Servicing InstructionsContents Installation Regulations Safety PrecautionsSafety Precautions Installation Regulations OIL SMELLS, Leaks or Fumes from the ApplianceGeneral Information General InformationStandard Package Technical Data Technical DataDescription BSPLayout & Components Layout & ComponentsCleaning Primary Systems Cleaning Primary SystemsMains Supplies Mains SuppliesMains Water Expansion Vessel Electric SupplyOIL Supply OIL SupplyG J HeadWater Systems & Pipework Water Systems & PipeworkSHOWERS/BIDETS Filling Primary Sealed SystemsDomestic HOT Water Condensate Pressure Relief Pipework Condensate Pressure Relief PipeworkCondensate Pipework Pressure Relief PipeworkBoiler Location Boiler Location ClearancesClearances FrontCabinet Mounted LOW Level Flue Terminal Positions Cabinet Mounted LOW Level Flue Terminal PositionsTerminal Position Positions High Level Flue TerminalHigh Level Flue Terminal PositionsBalanced External Oilfit Balanced External Oilfit Flue OptionsFlue Options AC DHorizontal Flue Options Cabinet Mounted BalancedBalanced Flue Options Unpacking the Boiler Lifting and Carrying PrecautionsUnpacking the Boiler Pipework & Flue Positions SafetyPipework & Flue Positions Boiler Installation Boiler InstallationFlue Installation Flue InstallationInstallation Notes Combustion Chamber Combustion ChamberHor Plan sectional view Hook the retainer J over the end two bafflesPipework Connections Pipework ConnectionsWater Connections OIL Supply ConnectionsPressure Relief Connection Condensate ConnectionOIL Burner & Pump OIL Burner & PumpOIL Burner OIL PumpRefitting Components Refitting ComponentsPlug burner lead E into control box F Programmer External Electrics MainsBoard ElectricsBlue Green/Yellow Br BrownRed WhitePRE-COMMISSIONING PRE-COMMISSIONING Checks ApplianceChecks Appliance Filling the System Filling the SystemStarting the Appliance Starting the ApplianceSafely dispose of the container/discharge Boiler lockout indicator on Pressure adjustment Vacuum gauge port 25/32Bleed & pressure gauge port Holder with oilBurner should be OFF and the circulating pump on Set the room thermostat to minimum Central heating Open all radiator valvesWater Treatment Water TreatmentPump and all radiators Finishing Commissioning Finishing CommissioningAppliance Inspection and Service Inspection and ServiceRoutine servicing Loosen clip D to detach air duct3.0mm Clean both sides of the fan impeller Clean the BurnerThoroughly clean any deposits Any debris and clean if necessaryFront 11.5 18.6 50 80EH55 80EH 12.0 22.2Short Parts List 12/18 Short Parts List 12/18Auto reset High Limit thermostat Part Number 8 716 107 640 Burner SterlingShort Parts List 18/25 Short Parts List 18/25Manifold access cover seal Short Parts List 25/32 Short Parts List 25/32Fault Finding Fault FindingFaulty Boiler Operation Problem Cause RemedyNoisy operation Pump noise from air in pump or OIL SmellsBase of the control box before replacing any components Neutral N and the pin, wire orMeasure all 230V tests between Control BOX Logic for 535 SE/LD RDB Fault FindingElectrical SchematicOIL Boiler Combustion Record Service 1 Date Excellence Comes AS Standard General checks

25/32kW, 12/18, 18/25 specifications

Bosch Appliances has carved out a reputation for engineering high-performance heating solutions, particularly with their range of heating systems including the 18/25, 12/18, and 25/32 kW models. These systems are designed to meet the diverse needs of residential and commercial spaces while maintaining energy efficiency and sustainability.

The Bosch 18/25 kW model excels in providing an optimal heating solution for medium to large residential properties. It is equipped with a highly efficient condensing boiler that extracts additional heat from flue gases, achieving significant energy savings. The built-in, user-friendly interface allows for easy programming and monitoring, which maximizes user convenience.

The 12/18 kW model provides a versatile opportunity for smaller homes or apartments. Its compact design ensures that it fits seamlessly into tighter spaces without sacrificing performance. The unit operates quietly, making it an excellent choice for residential areas where noise can be a concern. Additionally, it features the latest modulation technology, optimizing energy usage and maintaining consistent temperatures.

Finally, the 25/32 kW model is ideal for larger installations, offering robust performance even in high-demand scenarios. This model benefits from advanced heating management systems that enable intelligent control of heating zones, ensuring efficiency and comfort throughout the property. With its enhanced energy rating, the 25/32 kW model significantly reduces the carbon footprint, aligning with modern sustainability goals.

Across the board, Bosch Appliances integrates advanced technologies such as intelligent diagnostics, smart home compatibility, and eco-friendly materials. All models are constructed with durability in mind, featuring corrosion-resistant heat exchangers and high-quality components designed for longevity.

The customer-focused features, including comprehensive warranty packages and responsive customer service, further exemplify Bosch's commitment to quality. Overall, Bosch Appliances 18/25, 12/18, and 25/32 kW heating systems stand out for their innovative technology, efficient performance, and reliability, making them an excellent choice for those looking to upgrade their heating solutions.