Crown Boiler BWC Series installation instructions BWC Replacement Parts List

Page 64

BWC REPLACEMENT PARTS LIST

 

 

BWC150

BWC225

KEY

DESCRIPTION

 

 

 

 

CROWN

QUANTITY

CROWN

QUANTITY

 

 

PART #

PART #

 

 

 

 

Not Shown

11-1/2” Releasable Nylon Cable Wire Tie

960025

1

960025

1

 

 

 

 

 

 

Not Shown

6” Nylon Wire Tie

97-090

10

97-090

11

 

 

 

 

 

 

Not Shown

1-5/8” Hole Plug

900735

1

900735

1

 

 

 

 

 

 

Not Shown

5mm x 20mm Fast Acting, Ceramic Tube, 5 Amp Fuse

960005

1

960005

1

 

 

 

 

 

 

Not Shown

5mm x 20mm Time Delay, Glass Tube, 4 Amp Fuse

960004

1

960004

1

 

 

 

 

 

 

Not Shown

1/2” NPT x 3-1/2” Nipple

950063

1

NA

NA

 

 

 

 

 

 

Not Shown

1/2” NPT 90° Elbow

950049

1

NA

NA

 

 

 

 

 

 

Not Shown

Violet Jumper Wire

9602412

1

9602412

1

 

 

 

 

 

 

Not Shown

X5 Plug

9602416

1

9602416

1

 

 

 

 

 

 

Not Shown

Outdoor Sensor

240022

1

240022

1

 

 

 

 

 

 

Not Shown

4” Inlet Screen

60-601

1

60-601

1

 

 

 

 

 

 

62

Image 64
Contents BWC Series Page VII Product Description II SpecificationsIII Before Installing IV Locating the BoilerMinimum Clearance To Combustible Material Air for Ventilation Page VI Venting Vent System DesignHorizontal Direct Venting Vent Options 1,2 2a Summary of Horizontal Venting Options 3c Positioning Vent Terminal Under Overhangs Vertical Direct Vent System Vent Options 6 2b Summary of Vertical Venting Options VENT/ AIR Intake Fitting Equivalent Length Vent / Intake System Assembly Removing an Existing Boiler From a Common Chimney7a STAR-34 Connection to Vent Collar Z-VENT III Connection to Vent Collar SAF-T Vent Ezseal Connection to Vent Collar 10 Fasnseal Connection to Vent Collar 11 Condensate Piping Arrangement VII Gas Piping Gas Connection To BoilerViii System Piping General System Piping PrecautionsSystem Design Method 1 Primary/Secondary Piping Boiler in Secondary Loop Piping Method #1 Heat Only 4a Piping Method #1 Secondary Loop Piping Shaded Pipe and Circulator Sizing for Boiler Loop Fitting Equivalent Lengths Method 2 Primary/Secondary Piping Boiler in Primary Loop Piping Method #2 Heat Only 10a Piping Method #2 Secondary Loop Piping Bolded Page Flow GPM Piping for Special Situations 14 Chiller Piping IX Wiring Wiring Connections Diagram Ladder Diagram Page Start-up and Checkout For Your Safety Read Before Lighting BWC Series Lighting and Operating InstructionsBWC Burner Gas Valve Detail Typical CO2/O2 Combustion ReadingsPage Normal Display In Standby Mode XI OperationPage 170 Boiler Status First Digit Boiler StatusOutdoor Reset Curve XII. Service and Maintenance ContinuouslyPage XIII. Troubleshooting No Error Code DisplayedSoft Lockout Codes Displayed Code Condition Possible CausesHard Lockout Codes Displayed XIV Parts BWC Replacement Parts List TBD Page Page Page Page Ignition Electrode Gasket, 5mm 240011 Page BWC Replacement Parts List Page Page Page Page Page PN 980040 BWC 08/05

BWC Series specifications

The Crown Boiler BWC Series is a modern choice for heating needs, renowned for its efficiency and robust design. This series offers a range of residential and light commercial heating applicabilities, ensuring both comfort and reliability for users.

One of the standout features of the BWC Series is its efficiency. Crown Boilers utilize advanced technologies to maximize energy output while minimizing fuel consumption. With an AFUE (Annual Fuel Utilization Efficiency) rating often exceeding 90%, users can expect significant cost savings on their energy bills over time.

The BWC Series employs a high-quality, stainless steel heat exchanger, which not only enhances performance but also extends the lifespan of the boiler. This heat exchanger is designed to transfer heat efficiently, ensuring that the maximum amount of energy from the fuel is converted into usable heat. Additionally, the design helps to prevent corrosion and maintain system integrity over years of usage.

For technological advancements, the BWC Series incorporates a modulating gas valve which allows for precise control over the boiler's operation. This feature enables the system to adjust its output based on the heating demands of the home, resulting in improved energy efficiency and consistent comfort levels. Moreover, this modulating technology reduces the frequency of cycling, thereby prolonging the lifespan of the unit and minimizing wear and tear.

Another characteristic of the Crown Boiler BWC Series is its user-friendly interface. The boiler is equipped with a simple control panel that allows for easy monitoring and adjustment of settings. This accessibility is essential for users who want to manage their heating system without the need for extensive technical knowledge.

In terms of installation and maintenance, the BWC Series is designed with convenience in mind. Its compact footprint allows it to fit comfortably in a variety of spaces, making it an ideal choice for homes with limited installation areas. Additionally, Crown Boiler's commitment to high manufacturing standards ensures that the units require minimal maintenance, providing peace of mind to homeowners.

Overall, the Crown Boiler BWC Series is an excellent solution for those seeking efficient, reliable heating. Its combination of advanced technology, quality construction, and user-friendly design makes it an attractive option for any residential or light commercial application. Whether replacing an old system or installing a new one, the BWC Series delivers comfort and performance that can be depended upon.