Empire Comfort Systems DVX36DP91(N,P)-1, DVX36DP71(N,P)-1 Flush Wall Installation

Page 12

Flush Wall Installation

FINISHED WALL

6” OF NON-COMBUSTIBLE MATERIAL

NON-COMBUSTIBLE MATERIAL (INSTALLATION IS OPTIONAL

JOINT BETWEEN FINISHED

WALL AND UNIT SEALED

WITH 300° F, 149° C SEALANT

MATERIAL (SEALANT IS OPTIONAL)

Figure 12

Combustible Surround Installation

Attention: Cold climate installation recommendation: When installing this unit against a non-insulated exterior wall, it is recommended that the outer walls be insulated to conform to applicable insulation codes.

Vent Runs (Figures 14, 15, and 16)

In planning the installation for the fireplace, it is necessary to install certain components before the appliance is completely positioned and installed. These include the direct vent system, gas piping for the appliance and the electrical wiring.

The appliance can be mounted on any of the following surfaces:

1.A flat, hard combustible (burnable) surface.

2.A raised wooden platform.

3.Four (4) corner supports. (Example: Four (4) concrete masonry blocks.) These supports must be positioned so they contact all four (4) perimeter edges on the bottom of the unit.

VERTICAL, 90° ELBOW WITH HORIZONTAL

TERMINATION

3” (76mm)

MINIMUM CLEARANCE TO COMBUSTIBLES

2 X 4 HEADER

STAND OFF

MANTELSHELF

COMBUSTIBLE SURROUND

FINISHED WALL

6” OF NON-COMBUSTIBLE MATERIAL

FRONT TRIM OR

NON-COMBUSTIBLE

MATERIAL (INSTALLATION

IS OPTIONAL)

JOINT BETWEEN FINISHED WALL AND UNIT SEALED WITH 300°F (149°C) SEALANT MATERIAL (SEALANT IS OPTIONAL)

VENT CAP/

THIMBLE

DVX36,42

50 1/2” (1283mm)

TO BOTTOMWALL FIRESTOP OF UNIT

Figure 14

Figure 13

Page 12

25613-0-0309

Image 12
Contents DVX36DP31N,P-1 DVX42DP31N,P-1 DVX36DP71N,P-1 DVX42DP71N,P-1DVX36DP91N,P-1 DVX42DP91N,P-1 UL File NO. MH30033Table of Contents Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Specifications Fireplace DimensionsRemote Control Options Description Mantel Chart Figure ClearancesLocating Fireplace Clearances FigureInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Installation Framing and FinishingVent Pipe Clearance Installation Framing FigureFinishing Figures 12 Flush Wall Installation Combustible Surround Installation Vent Runs Figures 14, 15,VERTICAL, 90 Elbow with Horizontal Termination Dim Venting Fireplace TOP To Use the Vent Graph FigureExample a Example BInstallation of Flue Heat Shield Venting Fireplace TOPSee Figure Below Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FigureExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Items Required For Installation Tools Building Supplies Installation of the Vertical Flex Termination KitBefore You Start Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Quantity Number Item Description Repair Part No SuppliedDVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification DVVK-4RE Vent KIT Installation Instructions Sealing 4 102 mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemDVVK-4F Flex Vent Instructions Vertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Support Brackets Figure Installing Firestops Figures 50, 51, 52,Framing and Finishing Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsGeneral Maintenance See Figure Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureOperating Instructions TRWStanding Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure For Your Safety Read Before Lighting Intermittent Pilot Lighting InstructionsIntermittent Pilot Troubleshooting CheckoutOperation Trial For Ignition Pilot IgnitionIntermittent Pilot Troubleshooting Safety LockoutMain Burner Operation Ignition System Checks ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramRF Standing Pilot Lighting Instructions What to do if YOU Smell GASMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Parts List DVX36DP31,71,91 Index No Part Number DescriptionParts List DVX42DP31,71,91 FBB4 Variable Speed Blower Installation Blower MotorBlower Wheels Junction BOX Wiring Installation Instructions Brick Liner Installation Instructions Accent LampAccessories Stacked StoneHOW to Order Repair Parts Parts Not Under WarrantyWarranty Parts Master Parts Distributor ListStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.