Empire Comfort Systems DVX42DP71(N,P)-1 Parts List, Connecting to Rigid Vent System

Page 28

DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS (continued)

Follow correct option according to venting method.

Connecting Directly to Fireplace

If the air inlet and flue outlet tubes are to be connected directly to the unit (no rigid venting system is being used), then the gasket provided must be used to seal the 4” (102 mm) flue outlet tube. Peel the paper off the self-adhesive gasket and then wrap it around the end of the tube (if tube was cut, it is recommended to use cut end) as shown in Figure 41. Pull the gasket tight at all times while wrapping it around tube. The gasket ends should align, to form a complete seal. The overlapped section should NOT come in con- tact with the seam in the tube. Apply high temperature sealant to the opposite end of the tube (on the inside of the tube). The end with the gasket will attach to the back of the unit. Continue with Step 13.

 

 

PARTS LIST

INDEX

PART

 

DESCRIPTION

NUMBER

NUMBER

 

1

DV769

 

Vent Cap Assembly

2

19193

 

Outside Mounting Plate

3

19194

 

Air Inlet Tube

4

DV524

 

Flue Outlet Tube

5

19196

 

Firestop/Thimble Assembly

6

20527

 

Gasket

Connecting to Rigid Vent System

If the air inlet and flue outlet tubes are to be connected to a rigid venting system (and not directly to the back of the unit), then do not use the gasket provided. High temperature sealant should be applied to the outside of the 4” diameter (102 mm) flue outlet tube (if tube was cut, it is recommended to use cut end) and to the in- side of the tube on the end that connects to the vent cap. Continue with step 13.

Page 28

25613-0-0309

Image 28
Contents DVX36DP31N,P-1 DVX42DP31N,P-1 DVX36DP71N,P-1 DVX42DP71N,P-1DVX36DP91N,P-1 DVX42DP91N,P-1 UL File NO. MH30033Table of Contents Important Safety Information No Odor Detected Odor Fade LP-GAS Warning OdorSome Points to Remember Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Fireplace Dimensions SpecificationsRemote Control Options Description Mantel Chart Figure ClearancesLocating Fireplace Clearances FigureGAS Supply Installing a New Main Gas CockChecking Manifold Pressures Framing and Finishing InstallationVent Pipe Clearance Framing Figure InstallationFinishing Figures 12 Combustible Surround Installation Vent Runs Figures 14, 15, Flush Wall InstallationVERTICAL, 90 Elbow with Horizontal Termination Dim Venting Fireplace TOP To Use the Vent Graph FigureExample a Example BVenting Fireplace TOP Installation of Flue Heat ShieldSee Figure Below Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FigureExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Installation of the Vertical Flex Termination Kit Items Required For Installation Tools Building SuppliesBefore You Start Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Quantity Number Item Description Repair Part No SuppliedInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation InstructionsParts Verification DVVK-4RE Vent KIT Installation Instructions Sealing 4 102 mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemDVVK-4F Flex Vent Instructions Termination Clearances Vertical Sidewall InstallationsInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Firestops Figures 50, 51, 52, Installing Support Brackets FigureFraming and Finishing Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsGeneral Maintenance See Figure Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureOperating Instructions TRWStanding Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsIntermittent Pilot Operating Instructions Intermittent Pilot Wiring DiagramElectrical Connection Figure For Your Safety Read Before Lighting Intermittent Pilot Lighting InstructionsIntermittent Pilot Troubleshooting CheckoutOperation Trial For Ignition Pilot IgnitionSafety Lockout Intermittent Pilot TroubleshootingMain Burner Operation Ignition System Checks ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramRF Standing Pilot Lighting Instructions What to do if YOU Smell GASMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Parts List DVX36DP31,71,91 Index No Part Number DescriptionParts List DVX42DP31,71,91 Blower Motor FBB4 Variable Speed Blower InstallationBlower Wheels Junction BOX Wiring Installation Instructions Brick Liner Installation Instructions Accent LampAccessories Stacked StoneHOW to Order Repair Parts Parts Not Under WarrantyWarranty Parts Master Parts Distributor ListStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.