Empire Comfort Systems DVX36DP71(N,P)-1, DVX36DP91(N,P)-1, DVX36DP31(N,P)-1 Vent Clearances

Page 31

VENT CLEARANCES

VENT TERMINAL

AIR SUPPLY INLET

Figure 47

AREA WHERE TERMINAL IS NOT PERMITTED

A = *Clearance above grade, veranda, porch, deck or balcony [*12 inches (30cm) minimum]

B= clearance to window or door that may be opened [*12 inches (30cm) minimum for appliances < 100,000 Btuh (30kW)

C= clearance to permanently closed window [minimum 12 inches (30cm) recommended to prevent condensation on window]

D = vertical clearance to ventilated soffit located above the terminalwithinahorizontaldistanceof24inches(60cm)from the center of the terminal [18 Inches (46 cm) minimum

E = clearance to unventilated soffit [12 inches 30cm) minimum]

F = clearance to outside corner [See Page 30] G = clearance to inside corner [See Page 30]

H = *not to be installed above a meter/regulator assembly within 3 feet (90cm) horizontally from the center-line of the regulator

I= clearance to service regulator vent outlet [*6 feet (1.8m) minimum]

J= clearance to non-mechanical air supply inlet to building or the combustion air inlet to any other appliance [*12 inches

(30cm) minimum for appliances ≤ 100,000 Btuh (30 kW)

36 inches (90cm) minimum for appliances > 100,000 Btuh (30kW)]

K = clearance to a mechanical air supply inlet [* 6 feet (1.8m) minimum]

L= †clearance above paved sidewalk or a paved driveway located on public property [*7 feet (2.1m) minimum]

M= clearance under veranda, porch, deck, or balcony [*12 inches (30cm) minimum ¥]

a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings*

¥only permitted if veranda, porch, deck, or balcony, is fully open on a minimum of 2 sides beneath the floor*

*as specified in CGA B149 Installations Codes or ANSI Z223.1. Note: Local Codes or Regulations may require different clearances.

25613-0-0309

Page 31

Image 31
Contents UL File NO. MH30033 DVX36DP31N,P-1 DVX42DP31N,P-1DVX36DP71N,P-1 DVX42DP71N,P-1 DVX36DP91N,P-1 DVX42DP91N,P-1Table of Contents Important Safety Information No Odor Detected Odor Fade LP-GAS Warning OdorSome Points to Remember Vent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsIntroduction Fireplace Dimensions SpecificationsRemote Control Options Description Clearances Figure Mantel Chart FigureClearances Locating FireplaceGAS Supply Installing a New Main Gas CockChecking Manifold Pressures Framing and Finishing InstallationVent Pipe Clearance Framing Figure InstallationFinishing Figures 12 Combustible Surround Installation Vent Runs Figures 14, 15, Flush Wall InstallationVERTICAL, 90 Elbow with Horizontal Termination Dim Example B Venting Fireplace TOPTo Use the Vent Graph Figure Example aVenting Fireplace TOP Installation of Flue Heat ShieldSee Figure Typical Basement Installation Below Grade InstallationCutting the Hole Figure Positioning the FireplaceExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Installation of the Vertical Flex Termination Kit Items Required For Installation Tools Building SuppliesBefore You Start Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Number Item Description Repair Part No Supplied QuantityInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation InstructionsParts Verification Sealing 4 102 mm Diameter Flue Outlet Tube DVVK-4RE Vent KIT Installation InstructionsConnecting to Rigid Vent System Parts ListDVVK-4F Flex Vent Instructions Termination Clearances Vertical Sidewall InstallationsInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Firestops Figures 50, 51, 52, Installing Support Brackets FigureFraming and Finishing Framing and Finishing Horizontal Termination DVVK-5F Flex Vent Instructions InstallationDetermining Minimum Vent Height Above the Roof General MaintenanceSee Figure Installing the Vent System in a Chase Vertical TerminationVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Operating InstructionsStanding Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your SAFETY, Read Before LightingGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationIntermittent Pilot Operating Instructions Intermittent Pilot Wiring DiagramElectrical Connection Figure Intermittent Pilot Lighting Instructions For Your Safety Read Before LightingTrial For Ignition Pilot Ignition Intermittent Pilot TroubleshootingCheckout OperationSafety Lockout Intermittent Pilot TroubleshootingMain Burner Operation ARC Length Action Ignition System ChecksIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions Status Action RF Transmitter FunctionsRF Wiring Diagram Wiring Diagram with BlowerWhat to do if YOU Smell GAS RF Standing Pilot Lighting InstructionsMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Index No Part Number Description Parts List DVX36DP31,71,91Parts List DVX42DP31,71,91 Blower Motor FBB4 Variable Speed Blower InstallationBlower Wheels Junction BOX Wiring Installation Instructions Accent Lamp Brick Liner Installation InstructionsStacked Stone AccessoriesMaster Parts Distributor List HOW to Order Repair PartsParts Not Under Warranty Warranty PartsStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.