Empire Comfort Systems DVX36DP31(N,P)-1 Operating Instructions, Millivolt System

Page 44

OPERATING INSTRUCTIONS

750 Millivolt System

The standing pilot (750 millivolt system) is a continuous burning pilot. The pilot remains ON even when the main burner is OFF.

When you ignite the pilot, the thermopile produces millivolts (electrical current) which energizes the magnet in the gas valve. After 30 seconds to 1 minute time period you can release the gas control knob and the pilot will stay ON. Allow your pilot flame to operate an additional one (1) to two (2) minutes before you turn the gas control knob from the PILOT position to the ON position. This time period allows the millivolts (electrical current) to build-up to a sufficient level allowing the gas control to operate properly.

1.Follow the SAFETY and LIGHTING INSTRUCTIONS for standing pilot controls found in this manual and on labels found in control compartment behind the door assembly.

CAUTION: During the initial purging and subsequent lightings, never allow the gas valve control knob to remain depressed in the “pilot” position without pushing the piezo ignitor button at least once every second.

2.During the operating season, leave the control valve knob in the “ON” position. This will allow the pilot flame to remain lit. Turn the burner flame on or off with the fireplace Remote/OFF/ ON switch, wall switch or remote controls.

NOTE: The gas control valve allows you to increase or decrease the height of the main burner flame. The control valve has a pressure regulator with a knob as shown in Figure 67. Rotate the knob clockwise to “HI” to increase the flame height and counterclockwise to “LO” to decrease the flame height.

3.When the operating season is over, turn the Remote/OFF/ON switch to “OFF” and the control valve to “OFF”. The system, including the pilot light, will be shut down.

HI/LO REGULATOR

The OWNER should carefully read and follow these operating instructions at all times. Lower the door assembly to view the gas controls for the fireplace.

Initial Lighting

Upon completing the gas line or turning the gas valve on after it has been in the “OFF” position, a small amount of air will be in the lines. When first lighting the fireplace, it will take a few minutes for the lines to purge themselves of this air. Once the purging is complete, the fireplace will light and operate satisfactorily.

Subsequent lightings of the appliance will not require such purging if the gas valve is not turned to “OFF.”

Pilot Flame (Figure 68)

The thermopile/thermocouple (standing pilot) tips should be covered with flame.

Figure 68

CONTROL KNOB

Figure 67

Page 44

25613-0-0309

Image 44
Contents DVX36DP31N,P-1 DVX42DP31N,P-1 DVX36DP71N,P-1 DVX42DP71N,P-1DVX36DP91N,P-1 DVX42DP91N,P-1 UL File NO. MH30033Table of Contents Important Safety Information Some Points to Remember LP-GAS Warning OdorNo Odor Detected Odor Fade Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Remote Control Options Description SpecificationsFireplace Dimensions Mantel Chart Figure ClearancesLocating Fireplace Clearances FigureChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Vent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 InstallationFraming Figure VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, Dim Venting Fireplace TOP To Use the Vent Graph FigureExample a Example BSee Figure Installation of Flue Heat ShieldVenting Fireplace TOP Below Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FigureExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Before You Start Items Required For Installation Tools Building SuppliesInstallation of the Vertical Flex Termination Kit Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Quantity Number Item Description Repair Part No SuppliedParts Verification DVVK-4RE Vent KIT Installation InstructionsInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation Instructions Sealing 4 102 mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemDVVK-4F Flex Vent Instructions Information on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Framing and Finishing Installing Support Brackets FigureInstalling Firestops Figures 50, 51, 52, Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsGeneral Maintenance See Figure Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureOperating Instructions TRWStanding Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsElectrical Connection Figure Intermittent Pilot Wiring DiagramIntermittent Pilot Operating Instructions For Your Safety Read Before Lighting Intermittent Pilot Lighting InstructionsIntermittent Pilot Troubleshooting CheckoutOperation Trial For Ignition Pilot IgnitionMain Burner Operation Intermittent Pilot TroubleshootingSafety Lockout Ignition System Checks ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramRF Standing Pilot Lighting Instructions What to do if YOU Smell GASMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Parts List DVX36DP31,71,91 Index No Part Number DescriptionParts List DVX42DP31,71,91 Blower Wheels FBB4 Variable Speed Blower InstallationBlower Motor Junction BOX Wiring Installation Instructions Brick Liner Installation Instructions Accent LampAccessories Stacked StoneHOW to Order Repair Parts Parts Not Under WarrantyWarranty Parts Master Parts Distributor ListStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.