Empire Comfort Systems DVX36DP31(N,P)-1 Intermittent Pilot Lighting Instructions

Page 50

INTERMITTENT PILOT LIGHTING INSTRUCTIONS

FOR YOUR SAFETY READ BEFORE LIGHTING

Warning: If you do not follow these instructions exactly, a fire or explosion may result

causing property damage, personal injury or loss of life.

A. This appliance is equipped with an ignition device

• If you cannot reach your gas supplier, call

which automatically lights the pilot. Do not try to

the fire department.

light the pilot by hand.

C. Use only your hand to push in or turn the gas

B. Before lighting smell all around the appli-

control knob. Never use tools. If the knob will

ance area for gas. Be sure to smell next to the floor

not push in or turn by hand, don't try to repair

because some gas is heavier than air and will settle

it; call a qualified service technician. Force or

on the floor.

attempted repair may result in a fire or explo-

What To Do If You Smell Gas

sion.

 

• Do not try to light any appliance.

D. Do not use this appliance if any part has been

• Do not touch any electrical switch;

under water. Immediately call a qualified ser-

• Do not use any phone in your building.

vice technician to inspect the appliance and to

• Immediately call your gas supplier from a

replace any part of the control system and any

neighbor's phone. Follow the gas supplier's

gas control which has been under water.

instructions.

 

Lighting Instructions

1.Stop! Read the safety information above.

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

GAS CONTROL KNOB

SHOWN IN "OFF” POSITION.

OFF

ON

HONEYWELL

6.Turn gas control knob clockwise to "OFF."

7.Wait ten (10) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!

Follow "B" in the safety information above. If you don't smell gas, go to the next step.

8.Turn gas control knob counterclockwise to "ON".

9.Close louver front assembly.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" and call your service technician or gas supplier.

5. Lower louver front assembly.

To Turn Off Gas To Appliance

1.Set the thermostat to lowest setting. (if applicable.)

2.Turn off all electric power to the appliance if service is to be performed.

3.Open bottom louver assembly.

4.Turn gas control knob clockwiseto "OFF". Do not force.

5.Close bottom louver assembly.

Page 50

25613-0-0309

Image 50
Contents DVX36DP91N,P-1 DVX42DP91N,P-1 DVX36DP31N,P-1 DVX42DP31N,P-1DVX36DP71N,P-1 DVX42DP71N,P-1 UL File NO. MH30033Table of Contents Important Safety Information Some Points to Remember LP-GAS Warning OdorNo Odor Detected Odor Fade Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Remote Control Options Description SpecificationsFireplace Dimensions Locating Fireplace Mantel Chart FigureClearances Clearances FigureChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Vent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 InstallationFraming Figure VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, Dim Example a Venting Fireplace TOPTo Use the Vent Graph Figure Example BSee Figure Installation of Flue Heat ShieldVenting Fireplace TOP Below Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FigureExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Before You Start Items Required For Installation Tools Building SuppliesInstallation of the Vertical Flex Termination Kit Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Quantity Number Item Description Repair Part No SuppliedParts Verification DVVK-4RE Vent KIT Installation InstructionsInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation Instructions Sealing 4 102 mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemDVVK-4F Flex Vent Instructions Information on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Framing and Finishing Installing Support Brackets FigureInstalling Firestops Figures 50, 51, 52, Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsVertical Termination General MaintenanceSee Figure Installing the Vent System in a Chase Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Initial Lighting Operating InstructionsMillivolt System Pilot Flame FigureOperating Instructions TRWStanding Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsPilot and main burner extinguish while in operation Standing Pilot TroubleshootingFrequent pilot outage problem Glass sootsElectrical Connection Figure Intermittent Pilot Wiring DiagramIntermittent Pilot Operating Instructions For Your Safety Read Before Lighting Intermittent Pilot Lighting InstructionsOperation Intermittent Pilot TroubleshootingCheckout Trial For Ignition Pilot IgnitionMain Burner Operation Intermittent Pilot TroubleshootingSafety Lockout Ignition System Checks ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramRF Standing Pilot Lighting Instructions What to do if YOU Smell GASMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Parts List DVX36DP31,71,91 Index No Part Number DescriptionParts List DVX42DP31,71,91 Blower Wheels FBB4 Variable Speed Blower InstallationBlower Motor Junction BOX Wiring Installation Instructions Brick Liner Installation Instructions Accent LampAccessories Stacked StoneWarranty Parts HOW to Order Repair PartsParts Not Under Warranty Master Parts Distributor ListStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.