Empire Comfort Systems DVX36DP31(N,P)-1 Items Required For Installation Tools Building Supplies

Page 20

DVVK-4FV DIRECT VENT TERMINATION KIT (cont.)

PRE-INSTALLATION INFORMATION:

Items Required For Installation:

Tools

Building Supplies

Phillips Screwdriver

Framing Materials

Hammer

Wall Finishing Materials

Saw and/or saber saw

Caulking Material (Noncombustible)

Level

Support Strap supplies

Measuring Tape

 

Electric Drill and Bits

 

Pliers

 

Square

 

Tin Snips

 

Before You Start:

Plan your installation. Read these instructions and the fireplace installation manual before installing unit and vent system. Set unit in place and survey how best to vent the unit. After the vent configuration has been decided, stretch the flex pipe components out, then trim off what will not be needed.

Refer to the fireplace installation manual for information on vertical venting requirements. The maximum length of vent when using flex venting is 35 feet total. Contact your dealer or distributor for information on flex vent extension kits that may be added to the DVVK- 4FV kit, in order to terminate up to 35 feet. Available extension kits include the DVEK-10 (10’ Flex) or the DVEK-25 (25’ Flex) exten- sion kits. The extension kits include connection hardware.

Installation of the Vertical Flex Termination Kit

WARNING

Ensure that the venting system exits the structure through the roof and does not terminate less than 12 inches (305 mm) above the roof.

WARNING

Refer to your fireplace homeowner’s manual for the minimum and maximum venting requirement of your fireplace prior to installa- tion. Failure to do so may cause a fire hazard.

WARNING

This flexible pipe termination kit is ONLY for vertical terminations.

WARNING

Any horizontal run section must have a 1/4” rise for every one (1) foot of run towards the vent termination. Never allow the vent pipe to run downward. This could cause high temperatures and may present a fire hazard. This vertical kit may incorporate two (2) 90 de- gree bends, but must terminate vertically.

CAUTION

This flex vent kit can only be installed vertically off of the unit and must terminate vertically.

WARNING

Because of sharp edges, always use gloves when handling the flex vent components.

CAUTION

Vent connections should overlap a minimum of 1” for proper sealing.

CAUTION

Always stretch and secure venting with metal strapping secured with nails (nails and strapping not supplied) to ensure that the flex vent runs remain true.

Page 20

25613-0-0309

Image 20
Contents DVX36DP31N,P-1 DVX42DP31N,P-1 DVX36DP71N,P-1 DVX42DP71N,P-1DVX36DP91N,P-1 DVX42DP91N,P-1 UL File NO. MH30033Table of Contents Important Safety Information Some Points to Remember LP-GAS Warning OdorNo Odor Detected Odor Fade Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Remote Control Options Description SpecificationsFireplace Dimensions Mantel Chart Figure ClearancesLocating Fireplace Clearances FigureChecking Manifold Pressures Installing a New Main Gas CockGAS Supply Vent Pipe Clearance InstallationFraming and Finishing Finishing Figures 12 InstallationFraming Figure VERTICAL, 90 Elbow with Horizontal Termination Flush Wall InstallationCombustible Surround Installation Vent Runs Figures 14, 15, Dim Venting Fireplace TOP To Use the Vent Graph FigureExample a Example BSee Figure Installation of Flue Heat ShieldVenting Fireplace TOP Below Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FigureExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Before You Start Items Required For Installation Tools Building SuppliesInstallation of the Vertical Flex Termination Kit Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Quantity Number Item Description Repair Part No SuppliedParts Verification DVVK-4RE Vent KIT Installation InstructionsInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation Instructions Sealing 4 102 mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemDVVK-4F Flex Vent Instructions Information on Various Venting Routes and Components Vertical Sidewall InstallationsTermination Clearances Vent Clearances Vent System Identification Framing and Finishing Installing Support Brackets FigureInstalling Firestops Figures 50, 51, 52, Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsGeneral Maintenance See Figure Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureOperating Instructions TRWStanding Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsElectrical Connection Figure Intermittent Pilot Wiring DiagramIntermittent Pilot Operating Instructions For Your Safety Read Before Lighting Intermittent Pilot Lighting InstructionsIntermittent Pilot Troubleshooting CheckoutOperation Trial For Ignition Pilot IgnitionMain Burner Operation Intermittent Pilot TroubleshootingSafety Lockout Ignition System Checks ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramRF Standing Pilot Lighting Instructions What to do if YOU Smell GASMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Parts List DVX36DP31,71,91 Index No Part Number DescriptionParts List DVX42DP31,71,91 Blower Wheels FBB4 Variable Speed Blower InstallationBlower Motor Junction BOX Wiring Installation Instructions Brick Liner Installation Instructions Accent LampAccessories Stacked StoneHOW to Order Repair Parts Parts Not Under WarrantyWarranty Parts Master Parts Distributor ListStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.