Empire Comfort Systems DVX42DP71(N,P)-1 Intermittent Pilot Troubleshooting, Safety Lockout

Page 52

INTERMITTENT PILOT TROUBLESHOOTING (continued)

Safety Lockout

S8600H provides 100 percent shutoff, or safety lockout. A timer starts timing the moment the trial for ignition starts. Ignition spark continues only until the timed trial for ignition period ends. Then the module goes into safety lockout. Lockout de-energizes the first main valve operator and closes the first main valve in the gas control, stopping pilot gas flow. The control system must be reset by setting the thermostat below room temperature for one minute or by turning off power to the module for one minute.

Main Burner Operation

When the pilot flame is established, a flame rectification circuit is completed between the sensor and burner ground. The flame sensing circuit in the module detects the flame current, shuts off the

spark generator and energizes the second main valve operator. The second main valve opens and gas flows to the main burner, where it is ignited by the pilot burner. The flame current also holds the safety lockout timer in the reset (normal) operating condition.

When the call for heat ends, both main valve operators are de- energized, and both main valves in the gas control close.

Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

S8600H NORMAL OPERATING SEQUENCE

START

STAGE 1 Trial for Ignition

Thermostat, Wall Switch, Remote, Etc. Calls for Heat

Spark Generator Powered

First Valve (Pilot)

Operator Opens

POWER INTERRUPTION

System shuts off. Restarts when

power is restored.

PILOT FLAME FAILURE

Second main operator closes. Module starts trial for ignition.

STAGE 2

Main Burner

Operation

END

PILOT BURNER OPERATION

Pilot burner lights. Pilot burner does not light

Module senses flame current.

 

 

 

OR

 

MODULE

RESPONSE

 

 

 

 

 

 

S8600H

After 90 seconds*pilot valve

 

 

 

 

 

 

closes, spark stops.

 

 

 

 

 

 

* Lockout timing is stamped on module.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IF FLAME CURRENT SENSED

 

 

 

 

 

 

Spark generator off

 

 

 

 

 

 

Second valve operator

 

 

 

 

 

 

(Main) opens.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MAIN BURNER OPERATION

 

 

 

 

 

 

Module monitors pilot

 

 

 

 

 

 

flame current.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THERMOSTAT SATISFIED

 

 

 

 

 

 

Valves close. Pilot and

 

 

 

 

 

 

main burners are off.

 

 

 

 

 

Page 52

25613-0-0309

Image 52
Contents DVX36DP31N,P-1 DVX42DP31N,P-1 DVX36DP71N,P-1 DVX42DP71N,P-1DVX36DP91N,P-1 DVX42DP91N,P-1 UL File NO. MH30033Table of Contents Important Safety Information No Odor Detected Odor Fade LP-GAS Warning OdorSome Points to Remember Requirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsIntroduction Fireplace Dimensions SpecificationsRemote Control Options Description Mantel Chart Figure ClearancesLocating Fireplace Clearances FigureGAS Supply Installing a New Main Gas CockChecking Manifold Pressures Framing and Finishing InstallationVent Pipe Clearance Framing Figure InstallationFinishing Figures 12 Combustible Surround Installation Vent Runs Figures 14, 15, Flush Wall InstallationVERTICAL, 90 Elbow with Horizontal Termination Dim Venting Fireplace TOP To Use the Vent Graph FigureExample a Example BVenting Fireplace TOP Installation of Flue Heat ShieldSee Figure Below Grade Installation Typical Basement InstallationPositioning the Fireplace Cutting the Hole FigureExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Installation of the Vertical Flex Termination Kit Items Required For Installation Tools Building SuppliesBefore You Start Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Quantity Number Item Description Repair Part No SuppliedInstalling Wall Thimble/Firestop Assembly DVVK-4RE Vent KIT Installation InstructionsParts Verification DVVK-4RE Vent KIT Installation Instructions Sealing 4 102 mm Diameter Flue Outlet TubeParts List Connecting to Rigid Vent SystemDVVK-4F Flex Vent Instructions Termination Clearances Vertical Sidewall InstallationsInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Firestops Figures 50, 51, 52, Installing Support Brackets FigureFraming and Finishing Framing and Finishing Horizontal Termination Installation DVVK-5F Flex Vent InstructionsGeneral Maintenance See Figure Installing the Vent System in a ChaseVertical Termination Determining Minimum Vent Height Above the RoofReassembly and Resealing Vent Pipe System Vertical TerminationLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Operating Instructions Millivolt SystemInitial Lighting Pilot Flame FigureOperating Instructions TRWStanding Pilot Wiring Diagram For Your SAFETY, Read Before Lighting Standing Pilot Lighting InstructionsStanding Pilot Troubleshooting Frequent pilot outage problemPilot and main burner extinguish while in operation Glass sootsIntermittent Pilot Operating Instructions Intermittent Pilot Wiring DiagramElectrical Connection Figure For Your Safety Read Before Lighting Intermittent Pilot Lighting InstructionsIntermittent Pilot Troubleshooting CheckoutOperation Trial For Ignition Pilot IgnitionSafety Lockout Intermittent Pilot TroubleshootingMain Burner Operation Ignition System Checks ARC Length ActionIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions RF Transmitter Functions Status ActionWiring Diagram with Blower RF Wiring DiagramRF Standing Pilot Lighting Instructions What to do if YOU Smell GASMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Parts List DVX36DP31,71,91 Index No Part Number DescriptionParts List DVX42DP31,71,91 Blower Motor FBB4 Variable Speed Blower InstallationBlower Wheels Junction BOX Wiring Installation Instructions Brick Liner Installation Instructions Accent LampAccessories Stacked StoneHOW to Order Repair Parts Parts Not Under WarrantyWarranty Parts Master Parts Distributor ListStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.