Empire Comfort Systems DVX42DP91(N,P)-1 GAS Supply, Installing a New Main Gas Cock

Page 9

GAS SUPPLY

The gas pipeline can be brought in through the right or left side of the appliance. Consult the current National Fuel Gas Code, ANSI Z223.1 CAN/CGA-B149 (.1 or .2) installation code.

Recommended Gas Pipe Diameter

Pipe Length

Schedule 40 Pipe

Tubing, Type L

 

Inside Diameter

Outside Diameter

 

 

 

 

 

 

Nat.

L.P.

Nat.

L.P.

 

 

 

 

 

0-10ft

1/2"

3/8"

1/2"

3/8"

0-3m

12.7 mm

9.5 mm

12.7 mm

9.5 mm

 

 

 

 

 

11-40ft

1/2"

1/2"

5/8"

1/2"

4-12m

12.7 mm

12.7 mm

15.9 mm

12.7 mm

 

 

 

 

 

41-100ft

1/2"

1/2"

3/4"

1/2"

13-30m

12.7 mm

12.7 mm

19 mm

12.7 mm

 

 

 

 

 

101-150ft

3/4"

1/2"

7/8"

3/4"

31-46m

19 mm

12.7 mm

22.2 mm

1.9 mm

 

 

 

 

 

Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized.

Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.

The use of the following gas connectors is recommended:

ANS Z21.24Appliance Connectors of Corrugated MetalTubing and Fittings.

ANS Z21.45 Assembled Flexible Appliance Connectors of

Other Than All-Metal Construction

The above connectors may be used if acceptable by the authority having jurisdiction.The state of Massachusetts requires that a flexible appliance connector cannot exceed three feet in length.

Figure 6

 

Gas Supply Pressure (inches w.c.)

 

 

 

 

 

Minimum

Normal

Maximum

 

 

 

 

Natural Gas

4.5"

7.0"

*14.0"

 

 

 

 

LP (Propane)

10.8"

11.0"

14.0"

 

 

 

 

 

Manifold Pressure (inches w.c.)

 

 

 

 

 

Normal (HI)

 

 

 

 

Natural Gas

 

3.5"

 

 

 

 

 

LP (Propane)

 

10.0"

 

 

 

 

 

*NOTE: Remote "RF" Models - 10.5" w.c. maximum

Installing a New Main Gas Cock

Each appliance should have its own manual gas cock.

A manual main gas cock should be located in the vicinity of the unit. Where none exists, or where its size or location is not ad- equate, contact your local authorized installer for installation or relocation.

Compounds used on threaded joints of gas piping shall be resistant to the action of liquefied petroleum gases. The gas lines must be checked for leaks by the installer. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test should be made.

Never use an exposed flame to check for leaks. Appliance must be disconnected from piping at inlet of control valve and pipe capped or plugged for pressure test. Never pressure test with appliance connected; control valve will sustain damage!

NOTE: The millivolt gas controls are equipped with a captured screw type pressure test point, therefore it is not necessary to provide a 1/8" test point up stream of the control.

When using copper or flex connector use only approved fittings.

The appliance and it’s individual shut off valve must be disconnected from supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5kPa).

The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5kPa).

Attention! If one of the procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the fireplace gas valve, it will result in a hazardous condition.

Checking Manifold Pressures

Both Propane and Natural gas valves have a built-in pressure regulator in the gas valve. Natural gas models will have a manifold pressure of approximately 3.5" w.c. (.871kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 4.5" w.c. (1.120kPa) for the purpose of input adjustment to a maximum of 14.0" w.c. (3.484kPa). Propane gas models will have a manifold pressure approximately 10.0" w.c. (2.49kPa) at the valve outlet with the inlet pressure to the valve from a minimum of 10.8" w.c. (2.68kPa) for the purpose of input adjustment to a maximum of 14.0" w.c. (3.484kPa).

Figure 7

25613-0-0309

Page 9

Image 9
Contents DVX36DP71N,P-1 DVX42DP71N,P-1 DVX36DP31N,P-1 DVX42DP31N,P-1DVX36DP91N,P-1 DVX42DP91N,P-1 UL File NO. MH30033Table of Contents Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Vent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsIntroduction Specifications Fireplace DimensionsRemote Control Options Description Clearances Mantel Chart FigureLocating Fireplace Clearances FigureInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Installation Framing and FinishingVent Pipe Clearance Installation Framing FigureFinishing Figures 12 Flush Wall Installation Combustible Surround Installation Vent Runs Figures 14, 15,VERTICAL, 90 Elbow with Horizontal Termination Dim To Use the Vent Graph Figure Venting Fireplace TOPExample a Example BInstallation of Flue Heat Shield Venting Fireplace TOPSee Figure Typical Basement Installation Below Grade InstallationCutting the Hole Figure Positioning the FireplaceExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Items Required For Installation Tools Building Supplies Installation of the Vertical Flex Termination KitBefore You Start Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Number Item Description Repair Part No Supplied QuantityDVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification Sealing 4 102 mm Diameter Flue Outlet Tube DVVK-4RE Vent KIT Installation InstructionsConnecting to Rigid Vent System Parts ListDVVK-4F Flex Vent Instructions Vertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Support Brackets Figure Installing Firestops Figures 50, 51, 52,Framing and Finishing Framing and Finishing Horizontal Termination DVVK-5F Flex Vent Instructions InstallationSee Figure Installing the Vent System in a Chase General MaintenanceVertical Termination Determining Minimum Vent Height Above the RoofVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Millivolt System Operating InstructionsInitial Lighting Pilot Flame FigureTRW Operating InstructionsStanding Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your SAFETY, Read Before LightingFrequent pilot outage problem Standing Pilot TroubleshootingPilot and main burner extinguish while in operation Glass sootsIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure Intermittent Pilot Lighting Instructions For Your Safety Read Before LightingCheckout Intermittent Pilot TroubleshootingOperation Trial For Ignition Pilot IgnitionIntermittent Pilot Troubleshooting Safety LockoutMain Burner Operation ARC Length Action Ignition System ChecksIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions Status Action RF Transmitter FunctionsRF Wiring Diagram Wiring Diagram with BlowerWhat to do if YOU Smell GAS RF Standing Pilot Lighting InstructionsMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Index No Part Number Description Parts List DVX36DP31,71,91Parts List DVX42DP31,71,91 FBB4 Variable Speed Blower Installation Blower MotorBlower Wheels Junction BOX Wiring Installation Instructions Accent Lamp Brick Liner Installation InstructionsStacked Stone AccessoriesParts Not Under Warranty HOW to Order Repair PartsWarranty Parts Master Parts Distributor ListStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.