IMPORTANT SAFETY INFORMATION

Before enclosing the vent pipe assembly, operate the appliance to ensure it is venting properly.

DO NOT OPERATE THIS APPLIANCE WITHOUT GLASS FRONT PANEL INSTALLED

If this appliance is installed directly on carpeting, tile or other combustible material other than wood flooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance.

The base referred to above does not mean the fireproof base as used on wood stoves. The protection is for rugs that are extremely thick and light colored tile.

Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance.

Clothing or other flammable material should not be placed on or near the appliance.

Adequate accessibility clearances for servicing and proper operation.

This appliance must not share or be connected to a flue serving a separate solid-fuel burning appliance.

Keep the area around your appliance clear of combustible materials, gasoline and other flammable vapor and liquids.

Under no circumstances should any solid fuels (wood, coal, paper or cardboard etc.) be used in this appliance.

The flow of combustion and ventilation air must not be obstructed in any way.

Due to high temperatures the appliance should be located out

Do keep the appliance area clear and free from combustible

 

of traffic and away from furniture and draperies.

 

material, gasoline and other flammable vapors and liquids.

The glass front or any part removed for servicing the appliance

Do examine venting system periodically and replace damaged

 

must be replaced prior to operating the appliance.Work should

 

parts.

 

be done by a qualified service person.

Do make a periodic visual check of pilot and burners. Clean

 

 

Keep burner and control compartment clean.

 

and replace damaged parts.

Vent cap is hot while fireplace is in operation.

CAUTION: The glass used in your fireplace is ceramic glass.

Installation and repair should be done by a qualified service

 

If the glass is cracked or damaged in any way, it should be

 

replaced only with a complete glass frame assembly from

 

person. The appliance should be inspected before use

 

 

 

Empire. See parts list on Pages 63 and 64 for ordering.

 

and at least annually by a qualified service person. More

 

 

 

 

 

frequent cleaning may be required due to excessive lint from

Do not use this fireplace if any part has been under water.

 

carpeting, bedding materials, etc. It is imperative that control

 

Immediately call a qualified service technician to inspect the

 

compartments, burners and circulating air passageways of the

 

heater and to replace any part of the control system and any

 

appliance be kept clean.

 

gas control which has been under water.

Do not put anything around the fireplace that will obstruct

Any safety screen or guard removed for servicing an appliance

 

the flow of ventilation air.

 

must be replaced prior to operating the appliance.

Clearance in accordance with local installation codes and the

 

 

 

requirements of the gas supplier.

 

 

 

 

 

 

25613-0-0309

Page 3

Image 3
Contents UL File NO. MH30033 DVX36DP31N,P-1 DVX42DP31N,P-1DVX36DP71N,P-1 DVX42DP71N,P-1 DVX36DP91N,P-1 DVX42DP91N,P-1Table of Contents Important Safety Information LP-GAS Warning Odor No Odor Detected Odor FadeSome Points to Remember Vent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsIntroduction Specifications Fireplace DimensionsRemote Control Options Description Clearances Figure Mantel Chart FigureClearances Locating FireplaceInstalling a New Main Gas Cock GAS SupplyChecking Manifold Pressures Installation Framing and FinishingVent Pipe Clearance Installation Framing FigureFinishing Figures 12 Flush Wall Installation Combustible Surround Installation Vent Runs Figures 14, 15,VERTICAL, 90 Elbow with Horizontal Termination Dim Example B Venting Fireplace TOPTo Use the Vent Graph Figure Example aInstallation of Flue Heat Shield Venting Fireplace TOPSee Figure Typical Basement Installation Below Grade InstallationCutting the Hole Figure Positioning the FireplaceExamples TOP Vent RUN DVVK-4FV Direct Vent Termination KIT Items Required For Installation Tools Building Supplies Installation of the Vertical Flex Termination KitBefore You Start Step-By-Step Installation For Flex DV Kit Roof Pitch DIA. Flex Vent Pipe DIA. Flex Flue Pipe DIA. Flue Adaptor 35’ MAX Number Item Description Repair Part No Supplied QuantityDVVK-4RE Vent KIT Installation Instructions Installing Wall Thimble/Firestop AssemblyParts Verification Sealing 4 102 mm Diameter Flue Outlet Tube DVVK-4RE Vent KIT Installation InstructionsConnecting to Rigid Vent System Parts ListDVVK-4F Flex Vent Instructions Vertical Sidewall Installations Termination ClearancesInformation on Various Venting Routes and Components Vent Clearances Vent System Identification Installing Support Brackets Figure Installing Firestops Figures 50, 51, 52,Framing and Finishing Framing and Finishing Horizontal Termination DVVK-5F Flex Vent Instructions InstallationDetermining Minimum Vent Height Above the Roof General MaintenanceSee Figure Installing the Vent System in a Chase Vertical TerminationVertical Termination Reassembly and Resealing Vent Pipe SystemLOG Identification LOG Placement 13 LOG SET LOG Placement 13 LOG SET LOG Placement 13 LOG SET Log Set Parts List Index Letter Part Number Description Pilot Flame Figure Operating InstructionsMillivolt System Initial LightingTRW Operating InstructionsStanding Pilot Wiring Diagram Standing Pilot Lighting Instructions For Your SAFETY, Read Before LightingGlass soots Standing Pilot TroubleshootingFrequent pilot outage problem Pilot and main burner extinguish while in operationIntermittent Pilot Wiring Diagram Intermittent Pilot Operating InstructionsElectrical Connection Figure Intermittent Pilot Lighting Instructions For Your Safety Read Before LightingTrial For Ignition Pilot Ignition Intermittent Pilot TroubleshootingCheckout OperationIntermittent Pilot Troubleshooting Safety LockoutMain Burner Operation ARC Length Action Ignition System ChecksIntermittent Pilot Troubleshooting Green LED Status Codes RF Standing Pilot Operating Instructions Status Action RF Transmitter FunctionsRF Wiring Diagram Wiring Diagram with BlowerWhat to do if YOU Smell GAS RF Standing Pilot Lighting InstructionsMaintenance and Service Glass Removal and Replacement Figures 73 Parts View Index No Part Number Description Parts List DVX36DP31,71,91Parts List DVX42DP31,71,91 FBB4 Variable Speed Blower Installation Blower MotorBlower Wheels Junction BOX Wiring Installation Instructions Accent Lamp Brick Liner Installation InstructionsStacked Stone AccessoriesMaster Parts Distributor List HOW to Order Repair PartsParts Not Under Warranty Warranty PartsStudio Series Direct Vent Gas Fireplace Heater Firebox Dimensions Comfort Systems

DVX42DP71(N,P)-1, DVX36DP31(N,P)-1, DVX42DP91(N,P)-1, DVX42DP31(N,P)-1, DVX36DP71(N,P)-1 specifications

Empire Comfort Systems has long been a trusted name in heating solutions, and their line of direct vent gas fireplaces showcases a blend of innovation, style, and efficiency. Among their standout models are the DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1. Each of these models boasts unique features and technologies, making them ideal choices for modern living spaces.

One of the defining characteristics of these fireplaces is their direct vent system, which allows for safe and efficient venting of combustion gases. By drawing air from the outside, these models maintain indoor air quality and eliminate the need for a traditional chimney. This is particularly beneficial in homes where space is limited or where aesthetic considerations make a chimney impractical.

The DVX series is designed with user convenience in mind. Many models come equipped with a remote control, allowing homeowners to adjust settings such as flame height and heat output from the comfort of their favorite chair. The ability to customize the ambiance is enhanced by the inclusion of realistic ceramic logs and glowing embers, creating a warm and inviting atmosphere.

Efficiency is a key feature of the Empire Comfort Systems DVX series. These fireplaces are designed to maximize heat output while minimizing energy consumption. With high-efficiency ratings, they provide warmth without significantly impacting utility bills. Additionally, the models are available in both natural gas and propane variants, catering to different preferences and availability.

In terms of design, the DVX series offers versatile options that can seamlessly integrate with various home decors. With customizable fronts, finishes, and media choices, owners can match their fireplace to their home’s aesthetic, whether it be modern, traditional, or somewhere in between.

Maintenance is simplified, thanks to the easy-access features that allow for quick cleaning and servicing. The durable construction ensures long-lasting performance, making these fireplaces a worthwhile investment.

With their focus on efficiency, style, and advanced technology, Empire Comfort Systems’ DVX36DP91(N,P)-1, DVX36DP71(N,P)-1, DVX42DP31(N,P)-1, DVX42DP91(N,P)-1, and DVX36DP31(N,P)-1 models represent some of the best options available for homeowners seeking a reliable and attractive heating solution.