MODEL | FLUE TERMINATION APPROVALS | ||
|
|
TABLE 1
1.3 FLUE SYSTEM APPROVALS AND INSTALLATIONS
This model is approved to use
Figures 6 through 10 show the flue systems approved for use with these models. Approved flue system com- ponents are labeled for identification. NO OTHER FLUE SYSTEMS OR COMPONENTS MAY BE USED. De- tailed installation instructions are included with each flue termination kit and should be used in conjunction with this manual.
WARNING: THIS GAS APPLIANCE AND FLUE AS- SEMBLY MUST BE FLUED DIRECTLY TO THE OUT- SIDE AND MUST NEVER BE ATTACHED TO A CHIM- NEY SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. EACH GAS APPLIANCE MUST USE A SEPARATE FLUE
CAUTION: UNDER NO CONDITION SHOULD COM- BUSTIBLE MATERIAL BE CLOSER THAN 3 INCHES (2 1/2 INCHES AT WALL FIRESTOPS) FROM THE TOP OF THE 8
For alternative installations, other than depicted, con- tact your dealer for further information.
Refer to Figure 4 for required clearances to flue termi- nals.
STRAIGHT OUT HORIZONTAL FLUE SYSTEM
Figure 6 shows straight out horizontal flue systems and straight up vertical flue systems approved for use on this model.
ELBOWS
The flue systems installed on this gas heater may also include one (1), two (2), or three (3) 90 - degree elbow assemblies, in addition to the 45 - degree elbow re- quired at the unit.
Figures 7 through 10 and their corresponding tables show examples of vent configurations using elbows. The rela- tionships of vertical rise to horizontal run in vent con- figurations using elbows MUST be strictly adhered to.
ONE (1) 90-DEGREE ELBOW
Figure 7 shows an installation using one (1) 90-degree elbow. Dimension V is listed as MINIMUM vertical di- mensions and dimension H is listed as corresponding MAXIMUM horizontal dimensions.
TWO (2) 90-DEGREE ELBOWS
Figure 8 shows examples of possible installations us- ing two (2) 90-degree elbows. Dimension V is listed as MINIMUM vertical dimensions, dimension H is listed as MAXIMUM beginning horizontal dimensions, and dimension H+H1 is listed as corresponding TOTAL MAXIMUM horizontal dimensions.
THREE (3) 90-DEGREE ELBOWS
Figures 9 and 10 show examples of possible installa- tions using three (3) 90-degree elbows. Dimensions V are listed MINIMUM first vertical dimensions and di- mensions H are listed as beginning MAXIMUM hori- zontal dimensions. Dimensions H+H1 andH+H1+H2 are listed as TOTAL MAXIMUM horizontal dimensions. Dimensions V+V1 are listed as TOTAL MAXIMUM ver- tical dimensions.
NOTE: When the 450 elbow is attached horizontally, the supplied heat shield must be installed (see Figure 5).
HEAT SHIELD |
Figure 5
8