1.5.1INSTALLING THE ELECTRICAL SERVICE TO THE JUNCTION BOX
WARNING: TURN ELECTRICAL POWER OFF AT THE CIRCUIT BREAKER BEFORE BEGINNING IN- STALLATION.
1.Remove the electrical cover plate from the lower side of the heater. Remove the knockout from the plate and attach the Romex clamp (screws to the out- side.)
2.Feed the electrical services wires through the Romex clamp and secure the wire to the clamp.
3.Using the wire connector provided inside the junc- tion box, attach the neutral service wire to the blue wire, the hot service wire to the black wire, and the service ground wire to the ground screw stud of the junction box. See Figure 22 for wire connection de- tail and Figure 21 for a complete wiring diagram.
4.
!WARNING: DO NOT CONNECT 220 VAC TO THE GAS CONTROL VALVE OR CON- TROL WIRING SYSTEM OF THIS MODEL.
FIGURE 22
1.6 MANTEL CLEARANCES
Clearance to a mantelpiece is
IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 150° C. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON- COMBUSTIBLE MATERIAL (USING 150° C.
MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND. SEE FIGURE 24.
279 |
|
|
254 |
|
|
229 |
|
|
203 |
|
|
178 |
|
|
152 |
| 279 |
| 229 | |
|
| |
203 | 254 |
|
|
| |
152 |
|
|
178 |
|
|
TOP FRONT EDGE |
|
|
OF FIREPLACE |
|
|
NOTE: ALL DIMENSIONS ARE | ||
SHOWN IN MILLIMETERS. |
|
FIGURE 23
HIGH TEMP |
(300oF. 150oC. MIN.) |
SEAL JOINT |
FINISHED |
WALL |
STUD |
2 X 4 |
HEADER |
TOP STANDOFF |
HIGH TEMP |
(300oF. 150oC. MIN.) |
SEAL JOINT |
FIGURE 24
1.7 LOG INSTALLATION
Carefully remove the log packages from the heater and the tags from their packages. Handle logs gently. Place the logs in the heater by following the steps shown in Figure 25. Replace the glass door and dress guard previously removed prior to lighting the unit. Be certain the gas logs are properly positioned.