3.Check thermopile with millivolt meter. Take reading at “TH- TP&TP” terminals of gas valve. Should read 325 millivolts mini- mum while holding valve knob depressed in pilot position, pilot lit, and on/off switch “OFF”. Re- place faulty thermocouple if read- ing is below specified minimum.

4.Disconnect thermopile leads from the valve. With pilot burner "ON", take reading at thermopile leads - should read 325 millivolts minimum. Replace thermopile if reading is below this minimum.

III.Pilot burning, no gas burner, valve knob "ON", "on-off" switch "ON".

B. Open wire connection in pilot circuit.

C. Defective valve.

A. "ON-OFF" switch or wires de- fective.

B.Thermopile may not be gener- ating sufficient milli- voltage. (325m.v.)

1.Check wire continuity and con- nection in pilot circuit.

1.Disconnect the thermopile's red wire from the micro-switch and connect to terminal "TP" on the gas valve. Turn green knob to pilot position, depress and light pilot light. If meter reading is greater than 325 m.v. after 30 seconds, the pilot generator is good. If pilot does not stay lit, the valve is defective. If the meter reading is less than 325 m.v., the thermopile is defective.

1.Check "on-off" switch and wires for proper connections. Place jumper wires across terminals at switch-if burner comes on, re- place defective switch. If OK, place jumper wires across switch wires at gas valve-if burner comes on, wires are faulty or connec- tions are bad.

1.Recheck Symptom #2.

2.Pilot flame not physically close enough to thermopile.

29

Image 29
Contents Kensington Blvd., Lakeville, MN 55044, USA 952 Model ST-38HV-AUInstallation and Operation Instructions Table of Contents Diagram of ST-38HV-AU Installation InstructionsTop Ceiling Front Heater Clearance RequirementsFraming only and no Sheetrock on IN- Terior of Framing Model ST-38HV-AUClearances Straight OUT Horizontal Flue System Flue System Approvals and InstallationsElbows ONE 1 90-DEGREE ElbowStraight OUT Horizontal Flueing Vertical FlueingFlueing with ONE 1 90 Elbow Flueing with TWO 2 90 Elbows Flueing with Three 3 90 Elbows Flueing with Three 3 90 Elbows Install Support Brackets Installing Flue ComponentsAttach the First Flue Component to the Starting Collars Continue Adding Flue ComponentsFor Vertical Runs Installing Support Brackets Install FirestopsHole and New Framing Members Flue TerminationFor Vertical Terminations To locate the flue Connecting the GAS SupplyFAN Junction BOX Detail Mantel Clearances Installing the Electrical Service to the Junction BOXLOG Installation LOG Placement Instructions Page Page Operating Instructions Installer TestingOperating Cautions Safety & Lighting InformationTo Turn OFF GAS Appliance Safety Information For Your Safety Read Before LightingLighting Instructions FAN Operation Servicing and MaintenanceParts Replacement Removal of Components for ServiceAdjustments and Replacement Parts Removal of Covers for ServicingSymptom Possible Cause Corrective Action Troubleshooting ST-38HV-AUSymptom Possible Cause Corrective Action Symptom VII. Flame burns blue and lifts off burner Symptom Possible CauseST-38HV-AU ST-38HV-AU Service Parts ListService Parts Heat & GLO, a brand of Hearth & Home Technologies Inc Limited 10 Year Warranty