5 Fireplace Size Requirements

A. Minimum Fireplace Opening

Minimum fireplace opening requirements for a standard 3/4 inch deep surround are shown in Figure 5.1. For smaller openings, an optional 1-1/2 inch deep surround is available and dimensions are shown in Figure 5.2.

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

The firebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built fi rebox in order to gain minimum gas insert opening requirements.

Any smoke shelves, shields and baffles may be removed

from the factory built fi rebox if attached with mechanical fasteners.

The metal floor of the solid fuel firebox may be removed to facilitate the installation of the insert. The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace must be provided between the insert and the floor of the outer wrap. Use the levelling legs to raise the insert a minimum of 1/4 inch. The original fi replace may never be returned to solid fuel in this condition. The sidewalls and top structure of the fi rebox may not be altered with the exception of removable baffl es and dampers.

Cutting of any sheet metal parts of the fi replace in which the gas fi replace insert is to be installed is prohibited, except the fl oor as tested for and as noted above.

TOP VIEW

FRONT VIEW

C

A

E I

G

H

D

SIDE VIEW

F

B

MINIMUM FIREPLACE SIZE

 

Location

NDI35

 

 

NDI30

 

 

 

 

 

 

 

 

Inches

 

Millimeters

Inches

 

Millimeters

 

 

 

 

 

 

 

 

 

 

 

 

A

Rear Width

23-1/2

 

597

20-1/4

 

514

 

 

 

 

 

 

 

 

B

Front Width

34-5/8

 

879

30-1/2

 

775

 

 

 

 

 

 

 

 

C

Glass Opening Width

31-9/16

 

802

27-7/16

 

697

 

 

 

 

 

 

 

 

D

Glass Opening Height

15-11/16

 

398

12-13/16

 

325

 

 

 

 

 

 

 

 

E

Height-Front

24

 

610

20-1/2

 

521

 

 

 

 

 

 

 

 

F

Height-Rear

21-1/16

 

535

17-5/8

 

448

 

 

 

 

 

 

 

 

G**

Unit Depth

16

 

406

14-3/4

 

375

 

 

 

 

 

 

 

 

H

Venting Depth

10-1/2

 

267

9-1/2

 

241

 

 

 

 

 

 

 

 

I

Height to Top of

22

 

559

18-1/4

 

464

Glass Frame

 

 

 

 

 

 

 

 

 

*Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum

replace height for bends in vent pipe.

**Unit depth is measured to the back of the surround to give the depth needed for installation.

In addition to these dimensions, also reference Clearances and Mantel Projections (Section 5.B).

Figure 5.1 Fireplace Opening

Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK2226-900 Rev. G • 4/11

17

Image 17
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx CongratulationsHomeowner Reference Information User Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyClear Space Before Lighting FireplaceFinal inspection by Lighting Instructions IPIWhat to do if YOU Smell GAS GAS ValveLighting Instructions Standing Pilot For Your Safety Read Before Lighting Lighting InstructionsAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Maintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting LogsStanding Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum Fireplace Opening Fireplace Size RequirementsTOP View Front View Side View Minimum Fireplace Size NDI35 NDI30Side View TOP View Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVent Limits Venting Componentsfi replace opening Placing, Securing and Leveling the Appli- anceMasonry Installing Adaptor and Termination CapFactory Built Wood Burning Damper Flashing Kit OptionalFuel Conversion Gas InformationGas Pressure Gas ConnectionStanding Pilot Ignition System Wiring Wiring RequirementsIntelliFire Ignition System Wiring Electrical InformationValve WHT Pilot Assembly Thermocouple ThermopileRED Blower Plug 120V Existing Outlet Temperature Sensor Switch Optional Accessories RequirementsInstallation for Fan Optional Clearances to Mantels or other Combustibles above Appliance FinishingAppliance Setup Install the Log Assembly Log Set Assembly LOGS-NDI30 Models NDI30, NDI30-SPLOG #5 LOG #6LOG Log Set Installed Log Set Assembly LOGS-NDI35 Models NDI35, NDI35-SPGrate Tine Slot NDI30 NDI35 Air Shutter SettingAir Shutter Settings Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramModel Dimensions Direct Vent Flex Liner Kits Vent Kits ComponentsContact Information