Heatiator NDI30-SPFK, NDI35-SPFK Pilot Assembly Thermocouple Thermopile, Red, Valve WHT

Page 26

INTERMITTENT PILOT IGNITOR

IGNITION MODULE 3 VAC

TRANSFORMER

 

3 VAC

TO CORD ASSEMBLY 110V

BLACK

 

RED

BRN

BRN

BATTERY PACK

REMOTE WIRE

ASSEMBLY

I

S

ORG

WHT

GROUND TO

FIREPLACE

CHASSIS

ORANGE

GREEN

VALVE

 

 

WALL SWITCH OR

 

REMOTE CONTROL

 

NOTE: 1/4 IN. FEMALE SPADE

 

CONNECTORS CONNECT TO

 

THE REMOTE WIRE ASSEMBLY

 

ON

 

OFF

 

ON/OFF

Figure 10.2 IPI Wiring Diagram

SWITCH

PILOT ASSEMBLY

THERMOCOUPLE THERMOPILE

 

PIEZO

 

RED

VALVE

WHT

 

Figure 10.3 Standing Pilot Ignition Wiring Diagram

ROCKER

OPTIONAL WALL SWITCH,

THERMOSTAT OR REMOTE

SWITCH

 

26

Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK2226-900 Rev. G • 4/11

Image 26
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx CongratulationsHomeowner Reference Information Table of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Before Lighting FireplaceWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation Standing Pilot Flame PatternsGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed TOP View Front View Side View Minimum Fireplace Size Fireplace Size RequirementsMinimum Fireplace Opening NDI35 NDI30Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance fi replace openingFactory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressure Gas InformationFuel Conversion Gas ConnectionIntelliFire Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationValve WHT Pilot Assembly Thermocouple ThermopileRED Optional Accessories Requirements Blower Plug 120V Existing Outlet Temperature Sensor SwitchInstallation for Fan Optional Finishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup LOG #5 Log Set Assembly LOGS-NDI30 Models NDI30, NDI30-SPInstall the Log Assembly LOG #6LOG Log Set Assembly LOGS-NDI35 Models NDI35, NDI35-SP Log Set InstalledGrate Tine Slot NDI30 NDI35 Air Shutter SettingAir Shutter Settings Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramModel Dimensions Vent Kits Components Direct Vent Flex Liner KitsContact Information