INTERMITTENT PILOT IGNITOR
IGNITION MODULE 3 VAC
TRANSFORMER | |
| 3 VAC |
TO CORD ASSEMBLY 110V | BLACK |
|
RED
BRN | BRN |
BATTERY PACK
REMOTE WIRE
ASSEMBLY
I |
S |
ORG
WHT
GROUND TO
FIREPLACE
CHASSIS
ORANGE | GREEN |
VALVE |
|
| WALL SWITCH OR |
| REMOTE CONTROL |
| NOTE: 1/4 IN. FEMALE SPADE |
| CONNECTORS CONNECT TO |
| THE REMOTE WIRE ASSEMBLY |
| ON |
| OFF |
| ON/OFF |
Figure 10.2 IPI Wiring Diagram | SWITCH |
PILOT ASSEMBLY
THERMOCOUPLE THERMOPILE
| PIEZO |
| RED |
VALVE | WHT |
|
Figure 10.3 Standing Pilot Ignition Wiring Diagram
ROCKER | OPTIONAL WALL SWITCH, |
THERMOSTAT OR REMOTE | |
SWITCH |
|