Heatiator NDI35-SPFK, NDI30 Placing, Securing and Leveling the Appli- ance, fi replace opening

Page 22

CUT AND BEND

FLASHING AS NEEDED

TO FIT CHIMNEY

SEALANT

ADHESIVE

Figure 8.2

Trim chimney top plate to minimize excess overhang or bend over fl ue tile (see Figure 8.2).

Place 3/8 inch bead of 300º F silicone on fl ue tile top.

D.Placing, Securing and Leveling the Appli- ance

Install insert (without surround attached) into existing

 

fi replace while pulling collar slide plate forward.

Install gas line into hole provided on insert side.

WARNING! Risk of Fire! Only an approved Hearth & Home Technologies surround may be used to cover inte- gral grills on solid fuel burning fireplaces. No other com- ponents such as shrouds, sheetmetal plates, etc., may be used to seal off vents.

WARNING! Risk of Explosion! Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

WARNING! Risk of Explosion/Combustion Fumes! Connect vent sections per installation instructions.

Connect exhaust vent pipe ONLY to exhaust starting collar and termination cap center collar.

Connect inlet air vent ONLY to inlet air collar on appliance and the termination cap inlet air collar.

DO NOT allow vent to sag below connection point to appliance.

E. Remote Control

The receiver for the remotes may be installed BETWEEN the base pan of the insert and the fi rebox of the wood- burning fi replace or in the control cavity of the insert. See Figure 8.3.

• If applicable install remote control wires into insert side

(see Section 8.E.).

REMOTE

EXISTING SIDE REFRACTORY

Secure collar slide plate to appliance by placing locking

 

handle into position with locking tabs (see Figure 8.1)

 

and secure with #8 screw.

• Level the appliance from side to side and front to back. If

 

necessary, use the leveling legs included with the manual

 

bag to set each corner of the base.

• Position any excess flexible vent pipe back up into

 

chimney without sagging. Twist and push flex vent

 

together to shorten.

• Install fiberglass insulation pieces to back face of

 

surround.

• Attach surround. Follow instructions for surround

 

installation included with the front.

Push insert into the opening so that it tightly overlaps

 

the fi replace opening.

RECEIVER

UNIT

EXISTING BOTTOM OF

FIREPLACE

Figure 8.3

22

Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK2226-900 Rev. G • 4/11

Image 22
Contents What to do if you smell gas ModelsHOT Surfaces Homeowner Reference Information CongratulationsXxxxxxxx Table of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Before Lighting FireplaceWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotIssue Solutions Frequently Asked QuestionsAfter Appliance is Lit Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation Standing Pilot Flame PatternsGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components TOP View Front View Side View Minimum Fireplace Size Fireplace Size RequirementsMinimum Fireplace Opening NDI35 NDI30Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance fi replace openingFactory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressure Gas InformationFuel Conversion Gas ConnectionIntelliFire Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationRED Pilot Assembly Thermocouple ThermopileValve WHT Optional Accessories Requirements Blower Plug 120V Existing Outlet Temperature Sensor SwitchInstallation for Fan Optional Finishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup LOG #5 Log Set Assembly LOGS-NDI30 Models NDI30, NDI30-SPInstall the Log Assembly LOG #6LOG Log Set Assembly LOGS-NDI35 Models NDI35, NDI35-SP Log Set InstalledGrate Tine Slot Air Shutter Settings Air Shutter SettingNDI30 NDI35 Symptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Model Dimensions Appliance Dimension DiagramReference Materials Vent Kits Components Direct Vent Flex Liner KitsContact Information