Prepare the existing solid fuel masonry or factory built non-combustible fi rebox for installation.

A. Inspection and Cleaning

Prior to installing the gas insert:

Have the chimney and adjacent structure inspected and cleaned by qualifi ed professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certi- fi ed professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.

Replace component parts of the chimney and fi replace as specifi ed by the professionals.

Ensure all joints are properly engaged and the chimney is properly secured.

Ensure combustible mantel and surround clearances comply with applicable codes and regulations for solid- fuel fireplaces. In the absence of local or regional codes, refer to NFPA 211.

Ensure chimney is constructed of non-combustible materials.

Ensure chimney is clean and in good working order.

Ensure that all chimney cleanouts fi t properly to prevent air leakage into chimney.

B. Flue Damper

Fully lock the solid fuel fi replace’s fl ue damper in the open position, OR completely remove it.

C. Gas Line

Note: If the factory built fireplace has no gas access hole provided, an access hole of 1 inch (25 mm) diameter or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship - like manner. This access hole must be plugged with non-combustible insulation after the gas supply line has been installed.

Install gas line into fi rebox cavity.

Check local codes and gas line sizing requirements following NFPA51. See Section 9.

It is recommended that extra length of gas line be installed within the existing wood burner or masonry fireplace to allow removal of the insert for future servicing needs.

D. Fireplace Conversion Notice

Permanently attach the label with the following warning to the inside lower back of the fi replace fi rebox into which the insert is being installed. Silicone or mechanical fasteners may be required to properly secure the label.

WARNING! Risk of Fire! This fireplace has been con- verted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace re-approved by the authority having jurisdiction.

E. Electrical Outlet Box

An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fi replace to power the appliance. Each unit ships standard with a cord assembly to permit blowers or other optional acces- sories to be used. The accessories plug into the new out- let box or may be routed out onto the hearth to a nearby outlet.

20

Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK2226-900 Rev. G • 4/11

Image 20
Contents HOT Surfaces ModelsWhat to do if you smell gas Xxxxxxxx CongratulationsHomeowner Reference Information Table of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fixed Glass Assembly Remote Controls, Wall Controls and Wall SwitchesClear Space Before Lighting FireplaceLighting Instructions IPI Final inspection byWhat to do if YOU Smell GAS GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotAfter Appliance is Lit Frequently Asked QuestionsIssue Solutions Maintenance and Service Maintenance Tasks-HomeownerGlass Cleaning Remote ControlMaintenance Tasks-Service Technician Gasket Seal and Glass Assembly InspectionVenting LogsBurner Ignition and Operation Standing Pilot Flame PatternsGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Fireplace Size Requirements Minimum Fireplace OpeningTOP View Front View Side View Minimum Fireplace Size NDI35 NDI30Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Installing Vent Pipe and Appliance Connecting Vent PipeVent Limits Venting ComponentsPlacing, Securing and Leveling the Appli- ance fi replace openingInstalling Adaptor and Termination Cap MasonryFactory Built Wood Burning Damper Flashing Kit OptionalGas Information Fuel ConversionGas Pressure Gas ConnectionWiring Requirements Standing Pilot Ignition System WiringIntelliFire Ignition System Wiring Electrical InformationValve WHT Pilot Assembly Thermocouple ThermopileRED Optional Accessories Requirements Blower Plug 120V Existing Outlet Temperature Sensor SwitchInstallation for Fan Optional Finishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup Log Set Assembly LOGS-NDI30 Models NDI30, NDI30-SP Install the Log AssemblyLOG #5 LOG #6LOG Log Set Assembly LOGS-NDI35 Models NDI35, NDI35-SP Log Set InstalledGrate Tine Slot NDI30 NDI35 Air Shutter SettingAir Shutter Settings Standing Pilot Ignition System TroubleshootingSymptom Possible Causes Corrective Action Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramModel Dimensions Vent Kits Components Direct Vent Flex Liner KitsContact Information