12 Appliance Setup

A. Remove Glass Assembly

See Section 12.H.

B. Remove the Shipping Materials

Remove shipping materials from inside or underneath the fi rebox.

C. Clean the Appliance

Clean/vacuum any sawdust that may have accumulated inside the fi rebox or underneath in the control cavity.

D. Accessories

Install approved accessories per instructions included with accessories. Contact your dealer for a list of ap- proved accessories.

WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty.

F. Ember Placement

WARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually. Improperly placed embers interfere with proper burner operation.

Ember material is shipped with this gas appliance. To place the ember material:

Embers CANNOT be placed directly over ports. Care should be taken not to cover the lighting trail of ports (from back to front).

Place dime-size pieces of Glowing Embers® just in front of the port trail, but not on or in between the ports (see Figure 12.2). Care should be taken so that the ports are not covered. Failure to follow this procedure will likely cause lighting and sooting problems.

Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications.

E. Place the Lava Rock

WARNING! Risk of Explosion! Follow lava rock place- ment instructions in manual. DO NOT place lava rock on burner. Improperly placed lava rock interferes with proper burner operation.

Lava rock is shipped with this gas appliance. To place the lava rock:

Lava rock CANNOT be placed on the burner.

Place lava rock in front of and to the sides of the burner.

PLACE LAVA ROCK IN SHADED AREA ONLY

Figure 12.1 Placement of Lava Rock

EMBERS NOT

ALLOWED IN

PILOT AREA

Figure 12.2 Placement of Embers

30

Heatilator • NDI30, NDI30-SP, NDI35, NDI35-SP, NDI30-SPFK, NDI35-SPFK2226-900 Rev. G • 4/11

Image 30
Contents Models What to do if you smell gasHOT Surfaces Congratulations Homeowner Reference InformationXxxxxxxx Table of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Before Lighting FireplaceWhat to do if YOU Smell GAS Lighting Instructions IPIFinal inspection by GAS ValveFor Your Safety Read Before Lighting Lighting Instructions Lighting Instructions Standing PilotFrequently Asked Questions Issue SolutionsAfter Appliance is Lit Glass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation Standing Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components TOP View Front View Side View Minimum Fireplace Size Fireplace Size RequirementsMinimum Fireplace Opening NDI35 NDI30Mantel and Wall Projections Side View TOP ViewTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceConnecting Vent Pipe Venting ComponentsPlacing, Securing and Leveling the Appli- ance fi replace openingFactory Built Wood Burning Installing Adaptor and Termination CapMasonry Damper Flashing Kit OptionalGas Pressure Gas InformationFuel Conversion Gas ConnectionIntelliFire Ignition System Wiring Wiring RequirementsStanding Pilot Ignition System Wiring Electrical InformationPilot Assembly Thermocouple Thermopile REDValve WHT Optional Accessories Requirements Blower Plug 120V Existing Outlet Temperature Sensor SwitchInstallation for Fan Optional Finishing Clearances to Mantels or other Combustibles above ApplianceAppliance Setup LOG #5 Log Set Assembly LOGS-NDI30 Models NDI30, NDI30-SPInstall the Log Assembly LOG #6LOG Log Set Assembly LOGS-NDI35 Models NDI35, NDI35-SP Log Set InstalledGrate Tine Slot Air Shutter Setting Air Shutter SettingsNDI30 NDI35 Troubleshooting Symptom Possible Causes Corrective ActionStanding Pilot Ignition System Troubleshooting Symptom Possible Cause Corrective ActionIntelliFire Ignition System Ues to spark, and main Appliance Dimension Diagram Model DimensionsReference Materials Vent Kits Components Direct Vent Flex Liner KitsContact Information