I.Operating Characteristics:

1.Unit shall be capable of starting and running at 125 F ambient outdoor temperature per maxi- mum load criteria of ARI Standard 210/240.

2.Compressor with standard controls shall be ca- pable of operation in cooling down to 40 F am- bient outdoor temperature.

3.Unit provided with fan time delay to prevent cold air delivery before heat exchanger warms up.

4.Unit provided with fan time-delay after the ther- mostat is satis®ed.

J.Electrical Requirements:

All unit power wiring shall enter unit cabinet at a single location.

K.Motors:

1.Compressor motors shall be of the refrigerant- cooled type with line break thermal and current overload protection.

2.All fan motors shall have permanently lubricated- bearings and inherent automatic reset thermal overload protection.

3.Condenser-fan motor shall be totally enclosed.

L.Special Features:

1.Roof Curb:

Curb shall have seal strip and a wood nailer for ¯ashing and shall be installed per manufacturer's instructions.

2.25% Open Manual Outdoor-Air Damper:

Manual damper package shall consist of damper, birdscreen, and rainhood which can be preset to admit outdoor air for year-round ventilation.

3.Thermostat and Subbase:

To provide for one-stage heating and cooling in addition to manual or automatic changeover and fan control.

4.Electronic Programmable Thermostat:

Thermostat provides 2-stage heating and 2-stage cooling control with remote communication ability.

5.Natural-to-Propane Conversion Kit:

Kit shall be complete with burner ori®ce(s).

6.Low Ambient Package:

Package shall consist of a solid-state control and condenser coil temperature sensor for control- ling outdoor-fan motor operation, which shall al- low unit to operate down to 0° F outdoor ambi- ent temperature.

7.Compressor Short-Cycle Protection:

Solid-state control shall protect compressor by preventing short cycling.

8.Lifting Bracket Kit:

Kit shall provide attachment points for rigging straps. (Not required with optional base rail or down¯ow option applications.)

9.High- and Low-Pressure Switch Kits:

Switches provide additional safety features and protect the unit from running at unsuitable pressures.

10.Filter Rack:

Rack provides mounting location for ®lters when unit is in down¯ow application.

11.Crankcase Heater:

Heater warms crankcase oil to reduce refriger- ant migration (recommended on 208/230-v, single- phase units in sizes 024-042).

12.Base Rail:

Base rail provides holes for rigging and handling, and an elevated base for horizontal applications.

13.Down¯ow Option:

Option provides for vertical ductwork connec- tions. Unit shall be equipped with base rail.

14.High Altitude Kit:

Kit shall have new burner ori®ces for use in ap- plications from 2001 to 5000 feet.

15.Low NOx Kit:

Kit shall provide low NOx emissions for units be- ing installed in California Air Quality Manage-

ment Districts which require NOx emissions of 40 nanograms/joule or less.

27

Image 27
Contents Efcient operation Features/BenetsEasy installation Convertible duct congurationDurable, dependable components Model number nomenclature Table of contentsSeer Ð ARI* capacitiesCooling Capacities and Efficiencies Outdoor Sound ONE-THIRD Octave Band Data Ð DecibelsAfue Unit 48SS Heating Input Output Capacity TemperatureHeating Capacities and Efficiencies Rise Range FPhysical data Options and accessories Field-installed accessoriesUnit with Optional Base Rail 48SS018-042 Without Optional Base Rail Base unit dimensionsElectrical Unit Weight Corner Weight Unit Height 48SS018-042 with Optional Base RailUnit Electrical Unit Weight Corner Weight Characteristics48SS048,060 Without Optional Base Rail 48SS048,060 with Optional Base Rail Unit Electrical Unit WeightAccessory dimensions Roof Curb DimensionsPart Number Filter Selection procedure with exampleAccessory Part Number Manual Outdoor AIR Damper Filter Racks and FiltersCooling Capacities Performance dataCooling Capacities DRY Coil AIR DELIVERY* Ð Horizontal Discharge Unit Motor 460 Volt Horizontal Discharge SizeSpeed DRY Coil AIR DELIVERY* Ð Vertical Discharge Unit460 Volt Vertical Discharge Size WET Coil Pressure Drop Unit Size Airflow Pressure DropUnit Size Filter Typical piping and wiring Horizontal DischargeDownflow Discharge Application data Typical control wiring schematic 48SS030-060 208/230-3-60 Tran 48SS036-060Electrical data Sequence of operation ControlsHvac Guide Specications Guide specicationsPage Carrier Corporation · Syracuse, New York