Optional Hinged Access Doors --Whenthe optional service package is ordered or the if the hinged access doors option is ordered, the unit will be provided with external and internal hinged access dool_ to facilitate service.

Four external hinged access doors are provided. All extern;d doors _ue provided with 2 large 1/4 turn latches with folding bail-type handles. (Compressor access doors have one latch.) A single door is provided for filter and drive access. One door is

provided for control box access. The control box access door is interlocked with the non-fused disconnect which must be in the

OFF position to open the dool: Two doors are provided for ac- cess to the compressor compartment.

SEE

"C"

I

 

I

 

,@

@

I

 

I

 

Two internal access doors are provided inside the filter/ drive access dool: The filter access door (on the left) is secured by 2 small 1/4 turn latches with folding bail-type handles. This door must be opened prior to opening the drive access dool: The &ive access door is shipped with 2 sheet metal screws

holding the door closed. Upon initial opening of the dooL these screws may be removed and discarded. The door is then held shut by the filter access door, which closes over it.

@

@

@ @

48TJD016

I

 

 

 

o(_o

I

Io

@

@

,@

@

@

I

I

 

 

 

I

 

 

 

I

 

 

 

 

 

 

 

 

48TJD020-028

AND 48TJF016

 

 

 

o_o

 

@

@

@

48TJ F020-028

SPARK GAP .120" TO .140"

1

_RK

IAP .181"

DETAIL "C"

Fig. 57 -- Spark Gap Adjustment

44

Image 44
Contents Installation, Start-Up Service Instructions Accessory Curb Rig and Place Unit --Do not diop unit14-3/4 Package no HeightOUTLINEGPUN,T Dimensions Spreaderbars Detail aUnit Base Rail UnitDIM B DIM C Unit Weight STD Unit EconomizerBTD Unit Unit Weight DIM a DIM B DIM C WeightPhysical Data Evaporator FANOUTDOOR-AIR Inlet Screens Unit 48TJ Furnace SectionFreeze Protection Thermostat F Install Flue Hood and Wind Baffle Make Unit Duct Connections -- UnitTrap Condensate Drain -- See Fig InsideLP Gas Conversion Orifice Change -- This unit is factory asOrifice Quantity TBI VO Ltag EGAS Field Control Thermostat Wiring Thermostat AssemblyElectrical Data Make Outdoor-Air Inlet Adjust- ments Securing ScrewsPanel PANInstall All Accessories-- Install all Motormaster I Control InstallationMotormaster V Control Installation Motormaster V Control Package UsageItem Description 48TJ024,028AdjustFactory-Installed Options OutputsELD WntiEcono Motor GrinyelApplication Temperature Sensor Enthalpy Outdoor AIR Return33CSENTHSW Differential Enthalpy Control Wiring Outdoor JIN UnitEconoMiSerlVComponent Locations-- End View Optional Economiseriv and ECONOMISER2EconoMi$erlV Wiring Supply Air Sensor Temperature Resistance Values EconoMi$erlV Sensor UsageEconomiseriv Standard Sensors ECONOMI$ERIV11t,4 SR117 EconoMi$erlV Controller 002 Sensor Maximum Range SettingAOlI so+Nocv To x l---ff+ TR 002 Sensor Standard Settings MOISTUREMI$ER LlsvLPS TranCompressor Rotation Crankcase Heater Size 028 and Units withAirflow Fan Performance --48TJD016 Low Heat UnitsFan Performance --48TJD020 and 024 Low Heat Units Fan Performance 48TJD028 Low Heat Units Fan Performance --48TJF016 High Heat UnitsFan Performance 48TJF020 and 024 High Heat Units Fan Performance --48TJF028 High Heat UnitsAccessory/FlOP Static Pressure Accessory/FlOP Static Pressure In. wg --48TJ020-028Fan Rpm at Motor Pulley Settings Air Quantity LimitsOperating Sequence Evaporator-Fan Motor DataEvaporator-Fan Motor Efficiency COOLING. Units with ECONOMISER2, Premier COOLING, Units with ECONOMISER2, PremierOAT SPT HEATING. Unit with ECONOMI$ER2, PremierlinkCoil Maintenance and Cleaning Recommen Typical Gas Heating SectionEvaporator Fan Performance Adjustment LubricationCondenser and EVAPORATOR-FAN Motor Manufacturer LubricantEvaporator Fan Service and Replacement Motor SectionFixed Flange SINGLE-GROOVE With BeltBelt Tension Adjustment --To adjust belt tension Condenser-Fan AdjustmentGas Valve Adjustment Diagnostic IGC Control LEDs-- The IGC bomdProtective Devices Control Circuit, 24-7--This control circuit is pro48TJD016 SeeD o,,-PL1o-12 1011 1Oll IOllAHA BKR W/ATUnit Troubleshooting- Refer to Tables 27-29 Cooling Service Analysis Cause RemedyWill Not Than NormallyHeating Service Analysis Subcooler Service AnalysisProblem Cause MoistureMi$er TM DehumidificationMotor Fault Er LOC.rsOFF ValveEconoMi$erlV Input/Output Logic InputsDCV OutputsIndex Service Training Page RETURN-AIR Temperature Model no Serial no DateSupply Voltage Compressor Amps Supply FAN Amps Exhaust FAN Amps

48TJ016-028 specifications

The Carrier 48TJ016-028 is a notable model in the range of packaged rooftop units designed by Carrier, a leader in heating, ventilation, and air conditioning (HVAC) solutions. Tailored specifically for commercial applications, these units provide a blend of efficiency, durability, and reliability, making them suitable for a variety of settings, including offices, retail spaces, and industrial environments.

One of the standout features of the 48TJ series is its energy-efficient performance. Equipped with high-efficiency scroll compressors, these units offer superior cooling capacity while minimizing energy consumption. This aligns with modern sustainability goals, helping businesses reduce their carbon footprint and operational costs. Additionally, the 48TJ units comply with stringent industry standards, such as the ASHRAE 90.1 energy efficiency guidelines, ensuring that users receive a product that meets modern energy performance benchmarks.

The 48TJ016-028 units also include advanced technologies that enhance performance and user comfort. The inclusion of a sophisticated microprocessor control system facilitates precise temperature regulation, allowing for an optimal balance of cooling and heating based on real-time conditions. Moreover, the user-friendly controls make it easy for facility managers to monitor system performance and make adjustments as necessary.

Another notable characteristic of the 48TJ series is its flexible installation options. These rooftop units are designed for easy integration into existing building structures and can be installed on flat or pitched roofs. Their compact design and lightweight construction simplify the installation process while minimizing structural impacts on buildings.

Durability is paramount in the design of the 48TJ units as well. The cabinets are constructed from high-quality materials with corrosion-resistant coatings, ensuring a long lifespan even in harsh environmental conditions. The systems are also equipped with robust insulation to reduce sound levels and improve overall operating efficiency.

Furthermore, the Carrier 48TJ016-028 units offer various options for customization. Users can choose from different airflow configurations, heating options, and accessories, allowing for tailored solutions that meet specific requirements. Whether you are looking for a unit with enhanced filtration, economizer capabilities, or advanced humidity control, the 48TJ series provides the flexibility needed for diverse applications.

In summary, the Carrier 48TJ016-028 units deliver a compelling combination of energy efficiency, advanced technology, and robust construction, making them an ideal choice for commercial HVAC needs. With their versatile features and customizable options, they stand out as reliable solutions for maintaining comfortable indoor environments.