American Power Conversion AFX Series GPML/s at ft m external head, and operate on Ph, 60-Hz power

Page 40

Water-andglycol-cooled systems. The water/glycol-cooled systems shall consist of an evaporator section including evaporator coil, blower package(s), controls and electrical section, compressor(s), and a water/glycol-cooled condenser section. The condenser shall be stainless steel brazed plate design and shall be controlled by 2-way (3-way optional) head pressure-regulated valve(s). Maximum water pressure is 150 psi (1030 kPa).

Outside heat exchanger (drycooler) for glycol cooled systems only: The drycooler casing shall be of aluminum, and all structural supports, coil frame, motor-drive supports, and mounting legs shall be made of galvanized steel. The drycooler coil shall have copper tubes expanded into aluminum fins. Headers and connections shall be copper. The coil shall be pressure-tested and sealed for shipment. The drycooler motors shall have permanently lubricated, sealed, ball bearings, and internal overload protection. Motors shall be mounted inside the drycooler casing for weather protection and wired to a terminal strip in a weather- proof panel on the unit. The direct-drive, aluminum fan blade and painted steel hub assembly, shall be protected by a heavy-gauge, vinyl- coated, steel-wire fan guard. On multiple fan units, each fan section shall be separated by full-width baffles to prevent bypass air. The drycooler shall be sized for 95° F (35° C) ambient, and operate on _______ -V,

______ -ph, 60-Hz power.

Indoor floor mounted drycooler: The indoor floor-mounted drycooler shall be a draw-through design and include a quiet belt-driven, double inlet centrifugal blower(s), and a condenser coil with copper tubes expanded into aluminum fins. Belt(s) shall be sized for 200% of the system horsepower. All components shall be housed in a corrosion- resistant, heavy-gauge, steel cabinet to match the evaporator section in finish and construction, equipped with 1" (25 mm) supply and return air duct flanges. The drycooler section shall be sized _________° F (° C) ambient. The drycooler section shall be remotely mounted suitable for

__________ -V, ______ -ph, 60-Hz power.

Single pump package for glycol cooled systems only: The pump package shall be comprised of a centrifugal pump in a vented enclosure with pump starter, separate drycooler fan and pump circuit breakers, Aquastat, and fan cycling contractor(s) to control the fluid temperature. The controls shall be mounted in a weather-tight box. An expansion tank and Airtrol fitting shall be supplied for field installation. The pump size shall be sized for ______ GPM (L/s) at ________ ft (m) external head, and operate on _______-V, ______ -ph, 60-Hz power.

Dual pump package for glycol cooled system only: The dual pump package shall consist of two centrifugal pumps in an enclosure. Pump starters, automatic pump switch-over controls, lead-lag pump selector switch, separate drycooler fan and pump circuit breakers, aquastat, and fan cycling contractor to control the fluid temperature shall be mounted in a separate weather-tight box. An expansion tank and airtrol fitting shall be supplied for field installation. Each pump shall be sized for

______GPM(L/s) at ______ft (m) external head, and operate on

______-V, ______ -ph, 60-Hz power.

APC NetworkAIR AFX Series: Guide Specifications

35

Image 40
Contents NetworkAIRTM AFX Series Contents Guide Specifications Pump Specifications Page Available Models DownflowUpflow front-return Indoor top-discharge centrifugal condenserPage Overview IntroductionCapacity Air patternConfiguration Front accessHumidity control ComplianceDwhu Model SelectionPage Microprocessor Standard FeaturesController Overall cabinet SetpointBlower assembly Electrical panelHumidifier Electric reheatClogged filter alarm Cooling coilCondenser Air filterEmergency drain PanPage Optional Features EmergencyEnvironmental ExternalAPC NetworkAIR AFX Series Optional Features Reheat System ComponentsPage Net cooling capacity-air/remote condensing Performance SpecificationsModel Capacity in BTU/H Net cooling capacity-water 26T 28TNet cooling capacity-glycol Page Performance Data Air systemCoolant requirements Pump systemWater regulating valve-2-Way/3-Way, single seated Humidification-solid state electrode canisterFilters Compressor-scrollElectric Reheat Hot gas reheatHot water reheat Steam reheatConnection sizes Electrical Data Electric Reheat-6-14 tonHumidifier VoltageElectric Reheat-18-28 ton Steam/hot water/or no-reheat-6-14 ton Steam/hot water/or no-reheat-18-28 ton Indoor centrifugal condenser units Page General Guide SpecificationsProduct APC NetworkAIR AFX Series Guide Specifications APC NetworkAIR AFX Series Guide Specifications APC NetworkAIR AFX Series Guide Specifications GPML/s at ft m external head, and operate on Ph, 60-Hz power Visual and audible alarm OptionsAPC NetworkAIR AFX Series Guide Specifications Page Dimensional Data Downflow-6-8 tonDownflow-10-18 ton Downflow-20-28 ton Upflow front-return-6-8 ton Upflow front-return-10-18 ton Upflow front-return-20-28 ton Upflow rear-return-6-8 ton Upflow rear-return-10-18 ton Upflow rear-return-20-28 ton Indoor rear-discharge centrifugal condenser-6-8 ton Indoor rear-discharge centrifugal condenser-10-18 ton Indoor rear-discharge centrifugal condenser-20-28 ton Indoor top-discharge centrifugal condenser-6-8 ton Indoor top-discharge centrifugal condenser-10-18 ton Indoor top-discharge centrifugal condenser-20-28 ton Page Air-Cooled Condensers and Drycoolers Key to the model numberAir-cooled condenser-physical data LbsModel Temp Air-cooled condenser-electrical dataFLA MCA MOP Single-fan air-cooled condenser-6 ton Dual-fan air-cooled condenser-6-14 ton Triple-fan air-cooled condenser-14-20 ton Dual-fan air-cooled condenser-20-26 ton Triple-fan air-cooled condenser-26-28 ton Drycooler Glycol cooled drycooler-physical dataGlycol cooled drycooler-electrical data Tonnage Ambient FLA MCA MOPDual-fan fluid cooler-6-8 ton Triple-fan fluid cooler-10-12 ton Dual-fan fluid cooler-14-18 ton Triple-fan fluid cooler-20-28 ton Page Pump electrical data Pump SpecificationsFLA MCA Page Guidelines for Installation Service accessRoom preparation Unit locationPower unit RiggingFloorstand Utility connectionsWater supply Page APC Worldwide Customer Support

AFX Series specifications

The American Power Conversion (APC) AFX Series is a groundbreaking line of uninterruptible power supplies (UPS) designed to meet the demands of modern businesses. APC, a subsidiary of Schneider Electric, is known for its reliable power management solutions that ensure the availability of critical equipment. The AFX Series stands out for its advanced features, cutting-edge technologies, and robust characteristics that cater to a diverse range of applications.

One of the standout features of the AFX Series is its flexible architecture. The series offers modular scalability, allowing users to expand power capacity as needed. This modular design is particularly beneficial for growing businesses that require a power solution that can adapt to changing demands without the need for a complete replacement. The AFX units boast a compact footprint, making them suitable for deployment in server rooms, data centers, or environments with space constraints.

Another significant characteristic of the AFX Series is its high efficiency. The UPS units are designed to operate at a remarkable efficiency level, often exceeding 95%, which translates into reduced energy consumption and lower operating costs. This efficiency not only benefits the environment but also enhances the overall reliability of power delivery.

In terms of technology, the AFX Series leverages advanced lithium-ion battery technology. Lithium-ion batteries have a longer lifespan and faster charge times compared to traditional lead-acid batteries. This innovation ensures that uptime is maximized, while maintenance efforts are minimized, allowing IT personnel to focus on more critical tasks.

The AFX Series is also equipped with intelligent monitoring and management features. Users can take advantage of real-time data and analytics through an intuitive web interface, providing insights into power performance and battery health. This capability aids in proactive maintenance, ensuring potential issues are addressed before they lead to downtime.

Furthermore, the AFX Series supports a range of connectivity options, including SNMP, USB, and serial interfaces. These options enable seamless integration into existing management systems, allowing for centralized monitoring and control.

In summary, the American Power Conversion AFX Series is a powerful solution for organizations seeking reliability, efficiency, and scalability in their UPS systems. With its modular architecture, high operational efficiency, advanced lithium-ion technology, and user-friendly management capabilities, the AFX Series is an exemplary choice for businesses aiming to safeguard their critical infrastructure against power interruptions.