Energizer PORTABLE GAS DETECTION INSTRUMENT manual Alarm Setpoint Menu, Change Alarm Setpoint

Page 26

6.7 ALARM SETPOINT MENU

The “ALARM SETPOINT” can be adjusted by the user in the ALARM SETPOINT menu within the following ranges:

CO

= 5 to 250 ppm

Cl2

= 0.1 to 10.0 ppm

ClO2 = 0.10 to 2.00 ppm HCN = 0.1 to 50.0 ppm H2S = 5 to 100 ppm NH3 = 5 to 100 ppm NO2 = 0.2 to 5.0 ppm O2 LO = 0.0 to 21.0% O2 HI = 21.0 to 25.0% PH3 = 0.10 to 5.00 ppm SO2 = 0.5 to 20.0 ppm

Very low oxygen alarm settings are useful when the instrument is used to verify nitrogen purging. On leaving the setpoint function or on subsequent power on, the user will be prompted to verify the safety of abnormally low settings

To enter the ALARM SETPOINT menu, depress the “SELECT” pushbutton in the menu selection screen as described in Section 6.2 above. One of the following ALARM SETPOINT menu screens will appear:

 

<gas> ALARM SETPOINT

For Toxic Gases

HI ALARM = <_> ppm

 

CHANGE

OK

 

ALARM SETPOINT

For O2

HI ALARM = 23.5%

 

LO ALARM = 19.5%

 

 

CHANGE

OK

The setpoint shown is the factory default setting. If acceptable, depress

26

Image 26
Contents MINI-SA Portable GAS Detection Instrument 39NO US Scott Instruments Scott Instruments MINI-SA Portable GAS Detector Introduction Operational EnvironmentRegistration Battery Installation General Instructions UnpackingInstrument Description H2S Sensor shown for referenceAlarm Legends Audible Alarms Vibration Alarm Status LightGraphic Switch Functions and DisplaysSensor Pushbuttons Component LocationsOperating Instructions MINI-SA Version Instrument Turn on / OFFScott Instruments MINI-SA Version O2 Sensor InitializingMenu Do YOU Want to Turn Unit OFF? YesnoMenu Selection Nextselect Nextselect O2 Alarm SetpointPeak / Hold Next Select Configuration Nextselect Zero Calibration Menu Change Span Calibration Menu for Toxic GAS onlyAuto Zero Required Before Span Calibration Acknowledge Exit DownSET To GAS Cylinder Calibration AdapterSpan Calibration Approaching Failure Sensor Replacement MessageMent Message Replace SoonReset Show Peak Select Mode Peak HoldReset Show Peak Peak O2 Level Peak / Hold MenuReset Hide Peak Peak O2 Level Reset Hide PeakHold Activated Hold Mode Activate ExitReset Alarm Setpoint Menu Change Alarm SetpointChange O2 Alarm Down SETChange O2 Alarm Setpoint TWA / Stel Menu Toxic Gases only NON-LATCHING Latchok O2 AlarmNON-LATCHING Latchok Stel TWA Reset Show Disable TWA/STELResetdisable Resetenable Reset Show ON/OFF TWA/STELConfiguration Battery Password Saver Menu Configuration MenuBattery Saver Mode Configuration Enable Battery Saver MODE? YesnoEnter Password Upset Disable Battery Saver MODE? YesnoPassword Protection Password Protection For Advanced Menus Turnchange Onpassword Password Required For Advanced Menus Enter Exit PasswordEnter NEW Password Upset Verify NEW Password Upset Turn OFF Recal Oxygen Sensor Turn OFF RecalCalibration Gases Specifications Hydrogen Sulfide Specifications Carbon Monoxide Specifications Sulphur Dioxide Specification Phosphine Specifications Chlorine Specification Ammonia Specifications Chlorine Dioxide Specification Oxygen Specifications Hydrogen Cyanide Specification Nitrogen Dioxide Specifications

PORTABLE GAS DETECTION INSTRUMENT specifications

The Energizer Portable Gas Detection Instrument is an innovative device designed for the safety and convenience of users in various environments. It is specifically engineered to detect hazardous gases, offering a reliable solution for industries such as oil and gas, waste management, confined space entry, and emergency response.

One of the primary features of this instrument is its multi-gas detection capability. Equipped with advanced sensors, it can simultaneously monitor a variety of gases, including hydrogen sulfide (H2S), carbon monoxide (CO), methane (CH4), and oxygen (O2). This versatility makes it indispensable for workers who are exposed to potentially dangerous atmospheres, providing real-time data to help ensure their safety.

The Energizer Portable Gas Detection Instrument employs state-of-the-art sensor technologies, including electrochemical, catalytic, and infrared sensors. Electrochemical sensors are particularly effective for detecting toxic gases with high sensitivity and low cross-sensitivity, making them ideal for use in confined spaces. Catalytic sensors are used for combustible gases, providing a consistent and accurate reading of gas concentrations, while infrared sensors offer a non-contact method for measuring hydrocarbons and other gases, enhancing the safety profile of the device.

This instrument is designed with user-friendliness in mind. It features a large digital display that provides clear and concise readings, allowing operators to quickly assess gas levels even in low-light conditions. Furthermore, the instrument includes audible and visual alarms that alert users to high gas concentrations, ensuring prompt response in emergencies.

Durability is a key characteristic of the Energizer Portable Gas Detection Instrument. Built to withstand harsh industrial environments, it is often housed in rugged, IP-rated enclosures that protect against moisture, dust, and impacts. This ruggedness is complemented by a long battery life, which ensures that the device remains operational during extended periods of use.

In addition to its physical capabilities, the device also offers advanced connectivity features. Many models come equipped with Bluetooth or Wi-Fi capabilities, allowing for remote monitoring and data logging. This function is particularly useful for compliance purposes, enabling employers to maintain accurate records of gas exposure levels over time.

In summary, the Energizer Portable Gas Detection Instrument combines advanced sensing technologies, user-friendly features, durability, and connectivity, making it an essential tool for promoting safety in environments where gas hazards may arise. It stands out as a reliable choice for professionals committed to ensuring a safe working environment.