Energizer PORTABLE GAS DETECTION INSTRUMENT manual Resetenable, Reset Show ON/OFF TWA/STEL

Page 31

Depressing the “RESET” pushbutton will reset the TWA value, the STEL value, and time all to “0”. The instrument will automatically go back into the Operating Mode and begin collecting measurement data.

The “DISABLE” pushbutton turns off the TWA/STEL functions. If the TWA/ STEL functions are off, one of the following screens will be displayed:

<gas> TWA/STEL MENU TIME AVERAGE VALUES

For Toxic Gases

RESETENABLE

Depress the “RESET” pushbutton to go back to the Operating Mode. De- press the “ENABLE” pushbutton to turn on the TWA/STEL functions.

When the TWA/STEL functions are enabled, selecting the TWA/STEL Menu as described in Section 6.2 will display one of the following screens:

<gas> TWA/STEL MENU STEL = 0 ppm

For Toxic Gas

TWA

= 0 ppm @ 0:05

 

RESET

SHOW

ON/OFF TWA/STEL

Depress the “SHOW TWA/STEL” pushbutton to display the STEL and TWA values on the Operating Mode screen in real time in one of the following screens:

0 ppm <gas>

 

STEL = 1 ppm

For Toxic Gases

TWA = 0 ppm @ 0:03

 

MENU

To turn off the TWA/STEL display, go back to the TWA/STEL MENU. The screen will now show “HIDE TWA/STEL” over the right pushbutton. Select this pushbutton and the standard Operating Mode screen will appear.

The TWA/STEL data measurement functions will be reset by turning off the instrument whether the function is enabled or disabled.

31

Image 31
Contents MINI-SA Portable GAS Detection Instrument 39NO US Scott Instruments Operational Environment Scott Instruments MINI-SA Portable GAS Detector IntroductionGeneral Instructions Unpacking Registration Battery InstallationH2S Sensor shown for reference Instrument DescriptionAlarm Legends Audible Alarms Status Light Vibration AlarmPushbuttons Component Locations Switch Functions and DisplaysSensor GraphicOperating Instructions MINI-SA Version O2 Sensor Initializing Instrument Turn on / OFFScott Instruments MINI-SA VersionDo YOU Want to Turn Unit OFF? Yesno MenuMenu Selection Peak / Hold Next Select Nextselect O2 Alarm SetpointNextselect Configuration Nextselect Zero Calibration Menu Auto Zero Required Before Span Calibration Acknowledge Span Calibration Menu for Toxic GAS onlyChange SET DownExit Calibration Adapter To GAS CylinderSpan Calibration Replace Soon Sensor Replacement MessageMent Message Approaching FailurePeak / Hold Menu Select Mode Peak HoldReset Show Peak Peak O2 Level Reset Show PeakReset Hide Peak Reset Hide Peak Peak O2 LevelReset Hold Mode Activate ExitHold Activated Change Alarm Setpoint Alarm Setpoint MenuDown SET Change O2 AlarmChange O2 Alarm Setpoint NON-LATCHING Latchok NON-LATCHING Latchok O2 AlarmTWA / Stel Menu Toxic Gases only Resetdisable Reset Show Disable TWA/STELStel TWA Reset Show ON/OFF TWA/STEL ResetenableConfiguration Enable Battery Saver MODE? Yesno Configuration MenuBattery Saver Mode Configuration Battery Password Saver MenuPassword Protection Disable Battery Saver MODE? YesnoEnter Password Upset Password Required For Advanced Menus Enter Exit Password Password Protection For Advanced Menus Turnchange OnpasswordEnter NEW Password Upset Verify NEW Password Upset Turn OFF Recal Turn OFF Recal Oxygen SensorCalibration Gases Specifications Hydrogen Sulfide Specifications Carbon Monoxide Specifications Sulphur Dioxide Specification Phosphine Specifications Chlorine Specification Ammonia Specifications Chlorine Dioxide Specification Oxygen Specifications Hydrogen Cyanide Specification Nitrogen Dioxide Specifications

PORTABLE GAS DETECTION INSTRUMENT specifications

The Energizer Portable Gas Detection Instrument is an innovative device designed for the safety and convenience of users in various environments. It is specifically engineered to detect hazardous gases, offering a reliable solution for industries such as oil and gas, waste management, confined space entry, and emergency response.

One of the primary features of this instrument is its multi-gas detection capability. Equipped with advanced sensors, it can simultaneously monitor a variety of gases, including hydrogen sulfide (H2S), carbon monoxide (CO), methane (CH4), and oxygen (O2). This versatility makes it indispensable for workers who are exposed to potentially dangerous atmospheres, providing real-time data to help ensure their safety.

The Energizer Portable Gas Detection Instrument employs state-of-the-art sensor technologies, including electrochemical, catalytic, and infrared sensors. Electrochemical sensors are particularly effective for detecting toxic gases with high sensitivity and low cross-sensitivity, making them ideal for use in confined spaces. Catalytic sensors are used for combustible gases, providing a consistent and accurate reading of gas concentrations, while infrared sensors offer a non-contact method for measuring hydrocarbons and other gases, enhancing the safety profile of the device.

This instrument is designed with user-friendliness in mind. It features a large digital display that provides clear and concise readings, allowing operators to quickly assess gas levels even in low-light conditions. Furthermore, the instrument includes audible and visual alarms that alert users to high gas concentrations, ensuring prompt response in emergencies.

Durability is a key characteristic of the Energizer Portable Gas Detection Instrument. Built to withstand harsh industrial environments, it is often housed in rugged, IP-rated enclosures that protect against moisture, dust, and impacts. This ruggedness is complemented by a long battery life, which ensures that the device remains operational during extended periods of use.

In addition to its physical capabilities, the device also offers advanced connectivity features. Many models come equipped with Bluetooth or Wi-Fi capabilities, allowing for remote monitoring and data logging. This function is particularly useful for compliance purposes, enabling employers to maintain accurate records of gas exposure levels over time.

In summary, the Energizer Portable Gas Detection Instrument combines advanced sensing technologies, user-friendly features, durability, and connectivity, making it an essential tool for promoting safety in environments where gas hazards may arise. It stands out as a reliable choice for professionals committed to ensuring a safe working environment.