Energizer PORTABLE GAS DETECTION INSTRUMENT manual Nitrogen Dioxide Specifications

Page 48

NITROGEN DIOXIDE SPECIFICATIONS

Range:

150ppm

Response Time:

T90 < 25 seconds Operating Temperature Range:

-20 to +50 oC (-4 to +122 oF)

Graphic Display Temperature Range: -10 to +60 oC

(+14 to +140 oF)

Operating Humidity:

0to 90% RH, Non-Condensing

Recommended Storage Temperature:

0to 20 oC (32 to 68 oF)

Sensor Accuracy:

±3% of Applied Gas

Linearity:

±3% of Full Scale

Battery Life:

About 100 Hours - Non-Alarming About 800 Hours in Battery Save Mode

Sensor Cross Sensitivity:

Carbon Monoxide at 300 ppm: <15 ppm Hydrogen Sulfide, -1.2 ppm Sulpher Dioxide, 5 ppm: 0 ppm

Nitric Oxide, 35 ppm: 0 ppm

Nitrogen Dioxide, 5 ppm: 0 ppm

Chlorine, 1 ppm: -1 ppm

Consult Factory for additional information.

48

Image 48 Contents
MINI-SA Portable GAS Detection Instrument 39NO US Scott Instruments Scott Instruments MINI-SA Portable GAS Detector Introduction Operational EnvironmentRegistration Battery Installation General Instructions UnpackingInstrument Description H2S Sensor shown for referenceAlarm Legends Audible Alarms Vibration Alarm Status LightSwitch Functions and Displays SensorGraphic Pushbuttons Component LocationsOperating Instructions Instrument Turn on / OFF Scott InstrumentsMINI-SA Version MINI-SA Version O2 Sensor InitializingMenu Do YOU Want to Turn Unit OFF? YesnoMenu Selection Nextselect O2 Alarm Setpoint Peak / Hold Next SelectNextselect Configuration Nextselect Zero Calibration Menu Span Calibration Menu for Toxic GAS only Auto Zero Required Before Span Calibration AcknowledgeChange Down SETExit To GAS Cylinder Calibration AdapterSpan Calibration Sensor Replacement Message Ment MessageApproaching Failure Replace SoonSelect Mode Peak Hold Reset Show Peak Peak O2 LevelReset Show Peak Peak / Hold MenuReset Hide Peak Peak O2 Level Reset Hide PeakHold Mode Activate Exit ResetHold Activated Alarm Setpoint Menu Change Alarm SetpointChange O2 Alarm Down SETChange O2 Alarm Setpoint NON-LATCHING Latchok O2 Alarm NON-LATCHING LatchokTWA / Stel Menu Toxic Gases only Reset Show Disable TWA/STEL ResetdisableStel TWA Resetenable Reset Show ON/OFF TWA/STELConfiguration Menu Battery Saver ModeConfiguration Battery Password Saver Menu Configuration Enable Battery Saver MODE? YesnoDisable Battery Saver MODE? Yesno Password ProtectionEnter Password Upset Password Protection For Advanced Menus Turnchange Onpassword Password Required For Advanced Menus Enter Exit PasswordEnter NEW Password Upset Verify NEW Password Upset Turn OFF Recal Oxygen Sensor Turn OFF RecalCalibration Gases Specifications Hydrogen Sulfide Specifications Carbon Monoxide Specifications Sulphur Dioxide Specification Phosphine Specifications Chlorine Specification Ammonia Specifications Chlorine Dioxide Specification Oxygen Specifications Hydrogen Cyanide Specification Nitrogen Dioxide Specifications