Energizer PORTABLE GAS DETECTION INSTRUMENT manual Reset Hide Peak Peak O2 Level

Page 24

 

4

ppm

For Toxic Gases

 

<gas>

 

 

 

MAX = <_> ppm

 

MENU

 

 

20

%

 

 

O2

For O2

MAX = 21.5 %

 

MIN = 20.9 %

MENU

Current and peak readings update continuously while this screen is dis- played.

If the PEAK menu is accessed from a peak reading display, the option “SHOW PEAK” will read “HIDE PEAK” instead, as follows:

PEAK <gas> LEVEL

For Toxic Gases

MAX =<_> ppm

 

 

RESET

HIDE

 

PEAK

PEAK

 

PEAK O2

LEVEL

For O2

MAX =20.9 %

 

MIN = 20.2%

 

RESET

HIDE

 

PEAK

PEAK

Selecting “HIDE PEAK” will return the display to the standard Operating Mode screen with only the current reading displayed. The “SHOW PEAK” function is latching and will not change by turning the instrument OFF.

To reset the peak value, depress the “RESET PEAK” pushbutton in the PEAK menu. This will reset the MAX value to the current ambient reading. Turning the instrument OFF will also RESET the PEAK value the next time the unit is turned ON. The PEAK value will continue to be displayed until “HIDE PEAK” is selected in the PEAK menu.

24

Image 24
Contents MINI-SA Portable GAS Detection Instrument 39NO US Scott Instruments Scott Instruments MINI-SA Portable GAS Detector Introduction Operational EnvironmentRegistration Battery Installation General Instructions UnpackingInstrument Description H2S Sensor shown for referenceAlarm Legends Audible Alarms Vibration Alarm Status LightSwitch Functions and Displays SensorGraphic Pushbuttons Component LocationsOperating Instructions Instrument Turn on / OFF Scott InstrumentsMINI-SA Version MINI-SA Version O2 Sensor InitializingMenu Do YOU Want to Turn Unit OFF? YesnoMenu Selection Nextselect O2 Alarm Setpoint Peak / Hold Next SelectNextselect Configuration Nextselect Zero Calibration Menu Span Calibration Menu for Toxic GAS only Auto Zero Required Before Span Calibration AcknowledgeChange Down SETExit To GAS Cylinder Calibration AdapterSpan Calibration Sensor Replacement Message Ment MessageApproaching Failure Replace SoonSelect Mode Peak Hold Reset Show Peak Peak O2 LevelReset Show Peak Peak / Hold MenuReset Hide Peak Peak O2 Level Reset Hide PeakHold Mode Activate Exit ResetHold Activated Alarm Setpoint Menu Change Alarm SetpointChange O2 Alarm Down SETChange O2 Alarm Setpoint NON-LATCHING Latchok O2 Alarm NON-LATCHING LatchokTWA / Stel Menu Toxic Gases only Reset Show Disable TWA/STEL ResetdisableStel TWA Resetenable Reset Show ON/OFF TWA/STELConfiguration Menu Battery Saver ModeConfiguration Battery Password Saver Menu Configuration Enable Battery Saver MODE? YesnoDisable Battery Saver MODE? Yesno Password ProtectionEnter Password Upset Password Protection For Advanced Menus Turnchange Onpassword Password Required For Advanced Menus Enter Exit PasswordEnter NEW Password Upset Verify NEW Password Upset Turn OFF Recal Oxygen Sensor Turn OFF RecalCalibration Gases Specifications Hydrogen Sulfide Specifications Carbon Monoxide Specifications Sulphur Dioxide Specification Phosphine Specifications Chlorine Specification Ammonia Specifications Chlorine Dioxide Specification Oxygen Specifications Hydrogen Cyanide Specification Nitrogen Dioxide Specifications

PORTABLE GAS DETECTION INSTRUMENT specifications

The Energizer Portable Gas Detection Instrument is an innovative device designed for the safety and convenience of users in various environments. It is specifically engineered to detect hazardous gases, offering a reliable solution for industries such as oil and gas, waste management, confined space entry, and emergency response.

One of the primary features of this instrument is its multi-gas detection capability. Equipped with advanced sensors, it can simultaneously monitor a variety of gases, including hydrogen sulfide (H2S), carbon monoxide (CO), methane (CH4), and oxygen (O2). This versatility makes it indispensable for workers who are exposed to potentially dangerous atmospheres, providing real-time data to help ensure their safety.

The Energizer Portable Gas Detection Instrument employs state-of-the-art sensor technologies, including electrochemical, catalytic, and infrared sensors. Electrochemical sensors are particularly effective for detecting toxic gases with high sensitivity and low cross-sensitivity, making them ideal for use in confined spaces. Catalytic sensors are used for combustible gases, providing a consistent and accurate reading of gas concentrations, while infrared sensors offer a non-contact method for measuring hydrocarbons and other gases, enhancing the safety profile of the device.

This instrument is designed with user-friendliness in mind. It features a large digital display that provides clear and concise readings, allowing operators to quickly assess gas levels even in low-light conditions. Furthermore, the instrument includes audible and visual alarms that alert users to high gas concentrations, ensuring prompt response in emergencies.

Durability is a key characteristic of the Energizer Portable Gas Detection Instrument. Built to withstand harsh industrial environments, it is often housed in rugged, IP-rated enclosures that protect against moisture, dust, and impacts. This ruggedness is complemented by a long battery life, which ensures that the device remains operational during extended periods of use.

In addition to its physical capabilities, the device also offers advanced connectivity features. Many models come equipped with Bluetooth or Wi-Fi capabilities, allowing for remote monitoring and data logging. This function is particularly useful for compliance purposes, enabling employers to maintain accurate records of gas exposure levels over time.

In summary, the Energizer Portable Gas Detection Instrument combines advanced sensing technologies, user-friendly features, durability, and connectivity, making it an essential tool for promoting safety in environments where gas hazards may arise. It stands out as a reliable choice for professionals committed to ensuring a safe working environment.