Energizer PORTABLE GAS DETECTION INSTRUMENT manual Vibration Alarm, Status Light

Page 9

4.3 VIBRATION ALARM

An internal vibrating motor activates whenever theAudible Alarm sounds. The Vibration Alarm operates as a secondary alarm feature in high noise environ- ments where the audible alarm may be difficult to hear.

The Vibration Alarm is reset the same as the Audible Alarm as described in Section 4.2.

The Vibration Alarm will also pulse briefly whenever the MINI-SA instrument is turned ON or OFF.

WARNING

THE VIBRATION ALARM DOES NOT FUNCTION FOR THE LOW BAT- TERY INDICATION.

4.4 ALARM LIGHT

The SCOTT INSTRUMENTS MINI-SA instrument contains a Red Light Alarm LED (Light Emitting Diode) which flashes whenever any Alarm Condition oc- curs. It will continue to flash when the Audible Alarm is silenced and will flash as long as the alarm condition is present. In the LATCHING alarm mode, selected in the Alarm Setpoint Menu, after an alarm condition has cleared, the alarm indication will continue until the alarm is acknowledged by de- pressing a pushbutton. In the NON-LATCHING alarm mode, all alarm indica- tions clear when the alarm condition clears. In either mode, the instrument gives an “all clear” signal with three audible beeps, three flashes of the Red Alarm Light, and three vibration pulses when the alarm indication is cleared.

4.5 STATUS LIGHT

The instrument also has a Green Status LED that flashes periodically, indi- cating continuing instrument operation.

9

Image 9
Contents MINI-SA Portable GAS Detection Instrument 39NO US Scott Instruments Operational Environment Scott Instruments MINI-SA Portable GAS Detector IntroductionGeneral Instructions Unpacking Registration Battery InstallationH2S Sensor shown for reference Instrument DescriptionAlarm Legends Audible Alarms Status Light Vibration AlarmSensor Switch Functions and DisplaysGraphic Pushbuttons Component LocationsOperating Instructions Scott Instruments Instrument Turn on / OFFMINI-SA Version MINI-SA Version O2 Sensor InitializingDo YOU Want to Turn Unit OFF? Yesno MenuMenu Selection Nextselect O2 Alarm Setpoint Peak / Hold Next SelectNextselect Configuration Nextselect Zero Calibration Menu Span Calibration Menu for Toxic GAS only Auto Zero Required Before Span Calibration AcknowledgeChange Down SETExit Calibration Adapter To GAS CylinderSpan Calibration Ment Message Sensor Replacement MessageApproaching Failure Replace SoonReset Show Peak Peak O2 Level Select Mode Peak HoldReset Show Peak Peak / Hold MenuReset Hide Peak Reset Hide Peak Peak O2 LevelHold Mode Activate Exit ResetHold Activated Change Alarm Setpoint Alarm Setpoint MenuDown SET Change O2 AlarmChange O2 Alarm Setpoint NON-LATCHING Latchok O2 Alarm NON-LATCHING LatchokTWA / Stel Menu Toxic Gases only Reset Show Disable TWA/STEL ResetdisableStel TWA Reset Show ON/OFF TWA/STEL ResetenableBattery Saver Mode Configuration MenuConfiguration Battery Password Saver Menu Configuration Enable Battery Saver MODE? YesnoDisable Battery Saver MODE? Yesno Password ProtectionEnter Password Upset Password Required For Advanced Menus Enter Exit Password Password Protection For Advanced Menus Turnchange OnpasswordEnter NEW Password Upset Verify NEW Password Upset Turn OFF Recal Turn OFF Recal Oxygen SensorCalibration Gases Specifications Hydrogen Sulfide Specifications Carbon Monoxide Specifications Sulphur Dioxide Specification Phosphine Specifications Chlorine Specification Ammonia Specifications Chlorine Dioxide Specification Oxygen Specifications Hydrogen Cyanide Specification Nitrogen Dioxide Specifications

PORTABLE GAS DETECTION INSTRUMENT specifications

The Energizer Portable Gas Detection Instrument is an innovative device designed for the safety and convenience of users in various environments. It is specifically engineered to detect hazardous gases, offering a reliable solution for industries such as oil and gas, waste management, confined space entry, and emergency response.

One of the primary features of this instrument is its multi-gas detection capability. Equipped with advanced sensors, it can simultaneously monitor a variety of gases, including hydrogen sulfide (H2S), carbon monoxide (CO), methane (CH4), and oxygen (O2). This versatility makes it indispensable for workers who are exposed to potentially dangerous atmospheres, providing real-time data to help ensure their safety.

The Energizer Portable Gas Detection Instrument employs state-of-the-art sensor technologies, including electrochemical, catalytic, and infrared sensors. Electrochemical sensors are particularly effective for detecting toxic gases with high sensitivity and low cross-sensitivity, making them ideal for use in confined spaces. Catalytic sensors are used for combustible gases, providing a consistent and accurate reading of gas concentrations, while infrared sensors offer a non-contact method for measuring hydrocarbons and other gases, enhancing the safety profile of the device.

This instrument is designed with user-friendliness in mind. It features a large digital display that provides clear and concise readings, allowing operators to quickly assess gas levels even in low-light conditions. Furthermore, the instrument includes audible and visual alarms that alert users to high gas concentrations, ensuring prompt response in emergencies.

Durability is a key characteristic of the Energizer Portable Gas Detection Instrument. Built to withstand harsh industrial environments, it is often housed in rugged, IP-rated enclosures that protect against moisture, dust, and impacts. This ruggedness is complemented by a long battery life, which ensures that the device remains operational during extended periods of use.

In addition to its physical capabilities, the device also offers advanced connectivity features. Many models come equipped with Bluetooth or Wi-Fi capabilities, allowing for remote monitoring and data logging. This function is particularly useful for compliance purposes, enabling employers to maintain accurate records of gas exposure levels over time.

In summary, the Energizer Portable Gas Detection Instrument combines advanced sensing technologies, user-friendly features, durability, and connectivity, making it an essential tool for promoting safety in environments where gas hazards may arise. It stands out as a reliable choice for professionals committed to ensuring a safe working environment.