CHLORINE DIOXIDE SPECIFICATION

Range:

0.00to 2.00 ppm

Response Time:

T80 < 60 seconds Operating Temperature Range:

-20oto +50 oC (-4oto +122o F)

Graphic Display Temperature Range: -10 to +60 oC

(+14 to +140 o F)

Operating Humidity:

15 to 90% RH, Non-Condensing

Recommended Storage Temperature:

0to 20 oC (32 to 68 oF)

Sensor Accuracy:

±3% of Applied Gas

Linearity:

±3% of Full Scale

Battery Life:

About 100 Hours - Non-Alarming About 800 Hours in Battery Save Mode

Sensor Cross Sensitivity:

Chlorine at 3 ppm: 1 ppm

Carbon Monoxide at 300 ppm: 0 ppm

Hydrogen Sulfide, 15 ppm: -3 to 0 ppm

Sulphur Dioxide, 5 ppm: 0 ppm

Nitric Oxide, 35 ppm: 0 ppm

Consult Factory for additional information.

45

Image 45 Contents
MINI-SA Portable GAS Detection Instrument 39NO US Scott Instruments Operational Environment Scott Instruments MINI-SA Portable GAS Detector IntroductionGeneral Instructions Unpacking Registration Battery InstallationH2S Sensor shown for reference Instrument DescriptionAlarm Legends Audible Alarms Status Light Vibration AlarmSensor Switch Functions and DisplaysGraphic Pushbuttons Component LocationsOperating Instructions Scott Instruments Instrument Turn on / OFFMINI-SA Version MINI-SA Version O2 Sensor InitializingDo YOU Want to Turn Unit OFF? Yesno MenuMenu Selection Nextselect O2 Alarm Setpoint Peak / Hold Next SelectNextselect Configuration Nextselect Zero Calibration Menu Span Calibration Menu for Toxic GAS only Auto Zero Required Before Span Calibration AcknowledgeChange Down SETExit Calibration Adapter To GAS CylinderSpan Calibration Ment Message Sensor Replacement MessageApproaching Failure Replace SoonReset Show Peak Peak O2 Level Select Mode Peak HoldReset Show Peak Peak / Hold MenuReset Hide Peak Reset Hide Peak Peak O2 LevelHold Mode Activate Exit ResetHold Activated Change Alarm Setpoint Alarm Setpoint MenuDown SET Change O2 AlarmChange O2 Alarm Setpoint NON-LATCHING Latchok O2 Alarm NON-LATCHING LatchokTWA / Stel Menu Toxic Gases only Reset Show Disable TWA/STEL ResetdisableStel TWA Reset Show ON/OFF TWA/STEL ResetenableBattery Saver Mode Configuration MenuConfiguration Battery Password Saver Menu Configuration Enable Battery Saver MODE? YesnoDisable Battery Saver MODE? Yesno Password ProtectionEnter Password Upset Password Required For Advanced Menus Enter Exit Password Password Protection For Advanced Menus Turnchange OnpasswordEnter NEW Password Upset Verify NEW Password Upset Turn OFF Recal Turn OFF Recal Oxygen SensorCalibration Gases Specifications Hydrogen Sulfide Specifications Carbon Monoxide Specifications Sulphur Dioxide Specification Phosphine Specifications Chlorine Specification Ammonia Specifications Chlorine Dioxide Specification Oxygen Specifications Hydrogen Cyanide Specification Nitrogen Dioxide Specifications