Energizer PORTABLE GAS DETECTION INSTRUMENT manual Enter NEW Password Upset

Page 35

Use the “UP” and “SET” push-buttons to enter the correct password. Enter- ing the incorrect password will display an INCORRECT PASSWORD mes- sage and allow the user to enter the password again. When the correct password has been entered, the instrument will display the following screen:

PASSWORD PROTECTION

FOR ADVANCED MENUS

TURN CHANGE

OFF PASSWORD

Depress the “TURN OFF” pushbutton and the instrument will display the menus as described in section 6.2.

The PASSWORD menu in the CONFIGURATION menu will still require that the password be properly entered to change the password and/or turn on the PASSWORD PROTECTION feature after it has been turned off.

To change a password, navigate through the CONFIGURATION menu to the PASSWORD menu:

PASSWORD PROTECTION

FOR ADVANCED MENUS

TURN CHANGE

ONPASSWORD

Depress the “CHANGE PASSWORD” pushbutton. The following display will appear with the first digit flashing:

ENTER NEW PASSWORD 0000

UPSET

Depressing the “UP” pushbutton will increase the value of the flashing digit from 0 through 9. Depressing the “SET” pushbutton will set the digit and advance to the next digit. For example, we will set the password to “5678”. When the fourth digit (number 8) has been set by depressing the “SET” pushbutton, the display will change to the following screen:

35

Image 35
Contents MINI-SA Portable GAS Detection Instrument 39NO US Scott Instruments Operational Environment Scott Instruments MINI-SA Portable GAS Detector IntroductionGeneral Instructions Unpacking Registration Battery InstallationH2S Sensor shown for reference Instrument DescriptionAlarm Legends Audible Alarms Status Light Vibration AlarmPushbuttons Component Locations Switch Functions and DisplaysSensor GraphicOperating Instructions MINI-SA Version O2 Sensor Initializing Instrument Turn on / OFFScott Instruments MINI-SA VersionDo YOU Want to Turn Unit OFF? Yesno MenuMenu Selection Nextselect Nextselect O2 Alarm SetpointPeak / Hold Next Select Configuration Nextselect Zero Calibration Menu Change Span Calibration Menu for Toxic GAS onlyAuto Zero Required Before Span Calibration Acknowledge Exit DownSET Calibration Adapter To GAS CylinderSpan Calibration Replace Soon Sensor Replacement MessageMent Message Approaching FailurePeak / Hold Menu Select Mode Peak HoldReset Show Peak Peak O2 Level Reset Show PeakReset Hide Peak Reset Hide Peak Peak O2 LevelHold Activated Hold Mode Activate ExitReset Change Alarm Setpoint Alarm Setpoint MenuDown SET Change O2 AlarmChange O2 Alarm Setpoint TWA / Stel Menu Toxic Gases only NON-LATCHING Latchok O2 AlarmNON-LATCHING Latchok Stel TWA Reset Show Disable TWA/STELResetdisable Reset Show ON/OFF TWA/STEL ResetenableConfiguration Enable Battery Saver MODE? Yesno Configuration MenuBattery Saver Mode Configuration Battery Password Saver MenuEnter Password Upset Disable Battery Saver MODE? YesnoPassword Protection Password Required For Advanced Menus Enter Exit Password Password Protection For Advanced Menus Turnchange OnpasswordEnter NEW Password Upset Verify NEW Password Upset Turn OFF Recal Turn OFF Recal Oxygen SensorCalibration Gases Specifications Hydrogen Sulfide Specifications Carbon Monoxide Specifications Sulphur Dioxide Specification Phosphine Specifications Chlorine Specification Ammonia Specifications Chlorine Dioxide Specification Oxygen Specifications Hydrogen Cyanide Specification Nitrogen Dioxide Specifications

PORTABLE GAS DETECTION INSTRUMENT specifications

The Energizer Portable Gas Detection Instrument is an innovative device designed for the safety and convenience of users in various environments. It is specifically engineered to detect hazardous gases, offering a reliable solution for industries such as oil and gas, waste management, confined space entry, and emergency response.

One of the primary features of this instrument is its multi-gas detection capability. Equipped with advanced sensors, it can simultaneously monitor a variety of gases, including hydrogen sulfide (H2S), carbon monoxide (CO), methane (CH4), and oxygen (O2). This versatility makes it indispensable for workers who are exposed to potentially dangerous atmospheres, providing real-time data to help ensure their safety.

The Energizer Portable Gas Detection Instrument employs state-of-the-art sensor technologies, including electrochemical, catalytic, and infrared sensors. Electrochemical sensors are particularly effective for detecting toxic gases with high sensitivity and low cross-sensitivity, making them ideal for use in confined spaces. Catalytic sensors are used for combustible gases, providing a consistent and accurate reading of gas concentrations, while infrared sensors offer a non-contact method for measuring hydrocarbons and other gases, enhancing the safety profile of the device.

This instrument is designed with user-friendliness in mind. It features a large digital display that provides clear and concise readings, allowing operators to quickly assess gas levels even in low-light conditions. Furthermore, the instrument includes audible and visual alarms that alert users to high gas concentrations, ensuring prompt response in emergencies.

Durability is a key characteristic of the Energizer Portable Gas Detection Instrument. Built to withstand harsh industrial environments, it is often housed in rugged, IP-rated enclosures that protect against moisture, dust, and impacts. This ruggedness is complemented by a long battery life, which ensures that the device remains operational during extended periods of use.

In addition to its physical capabilities, the device also offers advanced connectivity features. Many models come equipped with Bluetooth or Wi-Fi capabilities, allowing for remote monitoring and data logging. This function is particularly useful for compliance purposes, enabling employers to maintain accurate records of gas exposure levels over time.

In summary, the Energizer Portable Gas Detection Instrument combines advanced sensing technologies, user-friendly features, durability, and connectivity, making it an essential tool for promoting safety in environments where gas hazards may arise. It stands out as a reliable choice for professionals committed to ensuring a safe working environment.