Cumberland Gap Wood Stove
REVERSIBLE FLUE COLLAR
The flue collar is reversible for either a top or rear venting installation. The unit is shipped with the flue collar in the top vent position.
ACCESSORY HORIZONTAL FLUE SHIELD
Part
IS REQUIRED ON ALL HORIZONTAL INSTALLATIONS.
CONVERTING COLLAR FOR REAR VENT INSTALLATION |
| |
1. Lift off cast top. Remove 4 Phillips head screws from the |
| |
| heat shield and discard heat shield. See circled areas in |
|
| Figure 10A. |
|
2. | Remove 4 Phillips head screws from the rear shield, 2 |
|
| on each side, lift rear heat shield off and set aside. |
|
3. | Remove 1 bolt from each side of the flue collar using a |
|
| Phillps head screwdriver and 7/16 wrench. |
|
4. | Turn flue collar to horizontal position. Inspect sealant to |
|
| ensure a leak free application. |
|
5. |
| |
6. | Attach required accessory Horizontal Flue Shield with | Figure 10B |
| screws provided. Figure 10B |
|
7.Place cast top on the unit. See Figure 10C for completed view.
Secure
Horizontal Flue
Heat Shield
Remove cast top
Completed View
Figure 10A
Remove bolts and
rotate flue collar
Discard heat shield
Rear Heat
Shield
Remove 4 screws and set rear shield & screws aside
Figure10C
Page 10 | September 1, 2008 |