Hearth and Home Technologies CUMBGAP-PMH Floor Protection, Side Fuel Door Locked Shut

Page 7

R

Cumberland Gap Wood Stove

FLOOR PROTECTION

Minimum Hearth Requirements ONLY

See page 6 for stove clearances

The floor must be non-combustible material, extending beneath heater and to the front/sides/rear as indicated. The floor must be a minimum of 1/2" thickness ("k" value = 0.84) non-combustible or otherwise adequately protected from radiant heat given off by the unit and from sparks and falling embers. A layer of thin brick or ceramic tile over a combustible floor is not sufficient. See Alternate Floor Protection on page 8.

In USA installations, it is necessary to install a non-combustible floor protector at least 16" in front and 8" to both sides of the fuel loading doors. See *exception below.

In Canada, similar floor protection must be provided 18" (450mm) in front and 8" (200mm) from the sides and rear of the stove. See *exception below.

*EXCEPTION: Non-combustible floor protections must extend beneath the flue pipe when installed with horizontal venting and extend 2" (51mm) beyond each side.

NOTE: Drawings are for illustration purposes only and are not to scale.

SIDE FUEL DOOR LOCKED SHUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200mm (8")

12”

 

 

 

 

 

(305mm)

 

 

 

 

 

 

 

Minimum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Front Fuel

loading door

16" (406mm) from fuel loading door

8" (200mm)

USA

200mm

 

200mm

1371mm

 

 

 

 

 

 

 

(54")

 

 

 

(8")

(8")

 

 

Minimum

 

 

 

 

 

 

 

39-1/8"

(994mm) Minimum

450mm (18")

CANADA

1089mm (42-7/8") Minimum

34-5/8"(879mm) Minimum

BOTH FUEL DOORS ACCESSIBLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8"(200mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuel loading doors

 

 

Minimum 16"

 

 

 

 

 

 

 

 

 

 

 

 

 

(406mm) from

39-

 

1/8"

Front

Side

 

 

 

 

 

 

 

fuel loading

(994mm)

 

 

 

 

 

 

door

Minimum

 

 

200mm

 

(8")

Mininum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

450mm

 

 

 

 

 

 

 

 

(18") from

 

200mm

 

 

 

 

 

fuel loading

 

Fuel loading doors

door.

 

 

 

 

(8")

 

 

1371mm

 

 

Front

Side

 

 

 

 

 

 

 

 

 

(54")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Minimum

8"

(200mm)

Minimum 16" (406mm) from fuel loading door

USA

Mininum 450mm

 

(18") from fuel

 

loading door.

CANADA

 

44-7/8"(1140mm) Minimum

1295mm (51") Minimum

September 1, 2008

7006-188E

Page 7

Image 7
Contents Cumberland Gap Important Safety NotesCUMBGAP-MBK CUMBGAP-PMH Report Number Cumberland Gap Wood StoveTable of Contents Installation Materials Needed for Your Safety Cumberland Gap Wood Stove Listings and Safety NoticesFront View TOP View Vent SpecificationsSide View Side View with Fuel Door Clearances to Combustibles UL and ULC Floor Protection Both Fuel Doors AccessibleSide Fuel Door Locked Shut USA Required Canada Recommended Horizontal VentingUnlock Side Fuel Door Locating Your StoveSide FUEL-LOADING-DOOR Locking Mechanism LEG Leveling SystemReversible Flue Collar Accessory Horizontal Flue ShieldCompleted View Chimney Height Requirements / Draft Flue SystemsFigures 14A & 14B Masonry ChimneySolid Pack Chimney with Metal Supports AS a Thimble Solid Pack Chimney with Metal Supports AS a Thimble Contd Connection to a Masonry FireplaceInterior Chimney Connection to a Metal Prefabricated ChimneyExterior Chimney Mobile Home Installation Part Outside AIR KIT InstallationHand Bend #2 Hand Bend #1Baffle Diverter Required on ALL Horizontal Installations 2nd Stage Kindling or 1st StageOpen Slide Left AIR ControlsPrimary Slide Control Start-Up Air Control START-UP AIR SystemBuilding a Fire Heat Output SettingsIncorrect Positions Correct Baffle & Blanket PlacementCorrect Position Optional Blower Operating Instructions OpacityBurn Rates Wood Selection and StorageASH Removal MaintenanceChimney Cleaning CreosoteDoor Handle Assemblies Glass ReplacementCare and Cleaning of Plated Surfaces Door GasketBaffle Removal & Installation Parts Diagram Description Service Parts & AccessoriesFirescreen Can only be used in Full Verticial Installations Date of Service Performed By Description of Service Service & Maintenance LogHearth & Home Technologies Limited Warranty Warranty PolicyCONDITIONS, Exclusions & Limitation of Liability Hearth & Home Technologies Limited Warranty Contd Cumberland Gap Wood Stove This page intentionally left blank Cumberland Gap Wood Stove This page intentionally left blank Dealer Telephone Cumberland Gap Wood Stove