Hearth and Home Technologies CUMBGAP-MBK, CUMBGAP-PMH Mobile Home Installation

Page 16

R

Cumberland Gap Wood Stove

MOBILE HOME INSTALLATION

You must use a Quadra-Fire Outside Air Kit Part 831-1780 for installation in a mobile home.

1. An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow. It must be unrestricted while unit is in use to prevent room air starvation which can cause smoke spillage and an inability to maintain a fire. Smoke spillage can also set off smoke alarms.

2.Stove must be secured to the mobile home structure. Use 1/4" (6mm) lag bolts with the appropriate length for your installation to secure stove through the hearth pad and into floor.

3.Stove must be grounded with #8 solid copper grounding wire or equivalent and terminated at each end with N.E.C. approved grounding device.

4.Stove must be installed with an approved UL103 HT ventilated chimney connector, UL103 HT chimney, and terminal cap with spark arrestor. Never use a single wall connector (stove pipe) in a mobile home installation. Use only double-wall connector pipe, Dura-Vent DVL, Selkirk metalbestos DS, Security DL double wall connector or any listed double-wall pipe connector.

5.Refer to pages 6-8of this manual or the Serial Number label on the back of the stove for clearances to combustibles.

6.Floor protections requirements on page 8 must be followed precisely.

Spark Arrestor Cap

Storm Collar

Roof Flashing

Joist Shield/Firestop

Listed Chimney

Outside Air Kit

Connector

Floor Protector

Outside Air Floor Vent

7.In Canada, this appliance must be connected to a 6” (152mm) factory-built chimney conforming to CAN/ULC-629M, STANDARD FOR FACTORY BUILT CHIMNEYS. Floor protection referenced on page 8 must be followed.

8.Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior of the structure.

9.Follow the chimney and chimney connector manufacturer’s instructions when installing the flue system for use in a mobile home.

WARNING! NEVER DRAW COMBUSTION AIR FROM A WALL, FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED SPACE SUCH AS AN ATTIC OR GARAGE.

CAUTION! THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED. (i.e.,

DO NOT CUT THROUGH FLOOR JOIST, WALL STUD, CEILING TRUSS, ETC.)

NOTE: Offsets from the vertical, not exceeding 45°, are allowed per Section 905(a) of the Uniform Mechanical Code (UMC). Offsets greater than 45° are considered horizontal and are also allowed, providing the horizontal run does not exceed 75% of the vertical height of the vent. Construction, clearance and termination must be in compliance with the UMC Table 9C. This installation also complies with NFPA 211.

WARNING! DO NOT INSTALL

IN SLEEPING ROOM.

NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5 ft. (411cm) from ground level for transportation purposes.

10.Burn wood only. Other types of fuels may generate poisonous gases (e.g., carbon monoxide).

11.If stove burns poorly while an exhaust blower is on in home, (i.e. kitchen range hood), increase combustion air.

Page 16

7006-188E

September 1, 2008

Image 16
Contents Cumberland Gap Important Safety NotesCUMBGAP-MBK CUMBGAP-PMH Cumberland Gap Wood Stove Report NumberTable of Contents Cumberland Gap Wood Stove Listings and Safety Notices Installation Materials Needed for Your SafetyFront View TOP View Vent SpecificationsSide View Side View with Fuel Door Clearances to Combustibles UL and ULC Floor Protection Both Fuel Doors AccessibleSide Fuel Door Locked Shut Horizontal Venting USA Required Canada RecommendedLocating Your Stove Side FUEL-LOADING-DOOR Locking MechanismLEG Leveling System Unlock Side Fuel DoorReversible Flue Collar Accessory Horizontal Flue ShieldCompleted View Flue Systems Chimney Height Requirements / DraftMasonry Chimney Figures 14A & 14BSolid Pack Chimney with Metal Supports AS a Thimble Connection to a Masonry Fireplace Solid Pack Chimney with Metal Supports AS a Thimble ContdInterior Chimney Connection to a Metal Prefabricated ChimneyExterior Chimney Mobile Home Installation Outside AIR KIT Installation PartHand Bend #1 Hand Bend #2Baffle Diverter Required on ALL Horizontal Installations Kindling or 1st Stage 2nd StageAIR Controls Primary Slide Control Start-Up Air ControlSTART-UP AIR System Open Slide LeftHeat Output Settings Building a FireIncorrect Positions Correct Baffle & Blanket PlacementCorrect Position Opacity Burn RatesWood Selection and Storage Optional Blower Operating InstructionsMaintenance Chimney CleaningCreosote ASH RemovalGlass Replacement Care and Cleaning of Plated SurfacesDoor Gasket Door Handle AssembliesBaffle Removal & Installation Parts Diagram Service Parts & Accessories DescriptionFirescreen Can only be used in Full Verticial Installations Service & Maintenance Log Date of Service Performed By Description of ServiceHearth & Home Technologies Limited Warranty Warranty PolicyCONDITIONS, Exclusions & Limitation of Liability Hearth & Home Technologies Limited Warranty Contd Cumberland Gap Wood Stove This page intentionally left blank Cumberland Gap Wood Stove This page intentionally left blank Cumberland Gap Wood Stove Dealer Telephone