Hearth and Home Technologies CFX-Crescent Vent System Approvals, Identifying Vent Components

Page 13

Step 3

Installing the

Vent System

A. Vent System Approvals

This model is approved to use SL-series direct vent pipe com- ponents and terminations (as indicated in this guide), and mod- el AK-CFX air kits. Approved vent system components are la- beled for identification. This pipe is tested and listed as an ap- proved component of the fireplace. The pipe is tested to be run inside an enclosed wall. There is NO requirement for inspection openings at each joint within the wall. There is no required pitch for horizontal vent runs. This model is not approved for use with SLK-01D termination cap. NO OTHER VENTING SYS-

TEMS OR COMPONENTS MAY BE USED.

Detailed installation instructions are included with each vent termina- tion kit and should be used in conjunction with this Installers Guide. Drawing below shows vent system components and terminations.

Vent System Components

 

 

 

VERTICAL

 

 

 

TERMINATION

STORM COLLAR

 

 

HORIZONTAL

ROOF FLASHING

 

 

TERMINATION

HORIZONTAL PIPE

 

 

 

 

 

 

SUPPORT

 

 

 

PIPE LENGTH

Vent System

WALL FIRESTOP

 

 

CEILING

Termination Kits

 

90 DEGREE

FIRESTOP

 

 

ELBOW

WALL BRACKET

 

 

 

 

 

 

COMBUSTION

 

 

 

AIR DUCT COLLAR

SLK-991DA

SLK-01TRD

NOTE: SLK-01D is NOT

 

 

 

 

 

 

approved for use.

 

Figure 4. Vent Components and Terminations

Identifying Vent Components

The vent systems installed on this gas fireplace may include up to eight 90° elbow assemblies. The relationships of vertical rise to horizontal run in vent configurations using 90° elbows MUST BE strictly adhered to. The rise to run relationships are shown in the venting drawings and tables. Refer to the diagrams on the next several pages.

NOTE: TWO 45° ELBOWS MAY BE USED IN PLACE OF ONE 90° ELBOW. RISE TO RUN RATIOS IN THE VENT SYSTEM MUST BE FOLLOWED IF 45° ELBOWS ARE USED.

WARNING: THIS UNIT IS DESIGNED TO OPERATE USING OUTSIDE COM-

!BUSTION AIR. IT IS MANDATORY TO INSTALL AN AK-CFX AIR KIT USING 4-INCH INSULATED DUCTING. THE 4-INCH (102MM) DUCT COLLAR FOR THE AIR KIT WILL COME MOUNTED TO THE FIREPLACE. SEE FIGURE 6.

NOTE: When installing the AK-CFX outside air kit, it is normally not necessary to install the air intake cap on the same wall as the exhaust termination cap. However, installations involving tall buildings or areas subjected to frequent high winds, it is recommended that the air intake cap be installed on the same wall as the exhaust termination cap.

Heat & Glo • CFX-CRESCENT705-900 Rev. P • 12/07

13

Image 13
Contents Model CFX-Crescent Installation and OperationSafety and Warning Information Section Installing the Fireplace Table of ContentsApprovals and Codes Getting StartedCFX-Crescent Log Set AssemblyAt Depot Service Parts List CFX-CrescentPost 002182991 Valve Assembly Pre 002182991 Valve AssemblyHigh Altitude Installations Installation CodesApprovals and Codes CodesRequirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsGetting Started Diagram of the CFX-CRESCENT Locating the fireplace Installing the FireplaceClearance Requirements 66 5/8 33 1/4 47 1/8 19 5/8 35 1/2Step Framing Fireplace Framing DimensionsIdentifying Vent Components Vent System ApprovalsSL-45D SL-90D 17-24 11 3/4 Straight UP Venting with eight 8 90 Elbows Attaching the First Vent Component to the Starting Collars Attach the First Vent Component to the Starting CollarsContinue Adding Vent Components Adding Venting Components Install Support BracketsInstalling Support Brackets 4. Install Firestops 10 Hole and Vent Pipe 9 Hole & New Framing Members Attic Firestop Vent Termination Trapezoid Termination Cap Vent Termination Minimum Clearances This also pertains to vertical vent systems installed Minimum Height from Roof to Lowest Discharge Opening Step Gas Control System Step Positioning Leveling, Securing FireplaceIntermittent Pilot Ignition IPI System Gas Supply Line Step Gas Supply LineIntermittent Pilot Ignition IPI Wiring Step Gas Pressure Requirements Wiring FireplacePressure Natural Gas Propane Appliance RequirementsWall Switch Optional AccessoriesWSK-MLT Sealant Material Hearth ExtensionsRemoving Glass Door Installing the TrimSave the log instructions with this manual Positioning the LogsPlacing the Ember Material and Lava Rock Double-check for faulty components Step Before Lighting Fireplace After InstallationDouble-check for gas leaks Double-check vent terminationsMaintaining and Servicing Your Fireplace Fireplace MaintenanceBurner Flame Patterns Contact Information