Introducing the Heat & Glo Gas Fireplaces

Heat & Glo direct vent gas fireplaces are designed to oper- ate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.

The information contained in this Installers Guide, unless noted otherwise, applies to all models and gas control systems. Gas fireplace diagrams, including the dimensions, are shown in this section.

Pre-install Preparation

This gas fireplace and its components are tested and safe when installed in accordance with this Installers Guide. Report to your dealer any parts damaged in shipment, particularly the condition of the glass. Do not install any unit with damaged, incomplete, or substitute parts.

The vent system components are shipped in separate pack- ages. The gas logs are packaged separately and must be field installed.

Read all of the instructions before starting the instal- lation. Follow these instructions carefully during the installation to ensure maximum safety and benefit. Failure to follow these instructions will void the own- er’s warranty and may present a fire hazard.

The Heat & Glo Warranty will be voided by, and Heat & Glo disclaims any responsibility for, the following actions:

Installation of any damaged fireplace or vent system component.

Modification of the fireplace or direct vent system.

Installation other than as instructed by Heat & Glo.

Improper positioning of the gas logs or the glass door.

Installation and/or use of any component part not manu- factured and approved by Heat & Glo, not withstanding any independent testing laboratory or other party approval of such component part or accessory.

ANY SUCH ACTION MAY POSSIBLY CAUSE A FIRE HAZARD.

When planning a fireplace installation, it’s necessary to determine:

Where the unit is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Framing and finishing details.

Whether optional accessories—devices such as a fan, wall switch, or remote control—are desired.

If the fireplace is to be installed on carpeting or tile, or on any combustible material other than wood flooring, the fireplace should be installed on a metal or wood panel that extends the full width and depth of the fireplace.

14

Image 14
Contents ST-HVB-IPI LCOR-HVB-IPI RCOR-HVB-IPI What to do if you smell gasSafety and Warning Information Table of Contents Pier-HVB-IPI NG, LP Exploded Parts Diagram / Vue éclatée des pièces PIER-HVB-IPIST-HVB-IPI ST-HVB-IPI LCOR-HVB-IPI LCOR-HVB-IPI RCOR-HVB-IPI RCOR-HVB-IPI PIER-HVB-IPI, ST-HVB-IPI L&RCOR-HVB-IPI Appliance Certification Installation CodesHigh Altitude Installations CertificationANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Fireplaces Diagram of the PIER-HVB-IPI Diagram of the ST-HVB-IPI Diagram of the LCOR-HVB-IPI and RCOR-HVB-IPI 121mmFraming the Fireplace Fireplace Dimensions and LocationsLocating the Fireplace Clearance RequirementsModel AT Each Joint Tems or Components MAY be Used Installing the Vent SystemVent System Approvals Identifying Vent ComponentsStraight OUT Straight UP Vertical VentingMAX .2 M Max. Run 24 610 mmVenting with One 90 Elbow Venting with Two 90 Elbows Venting with Two 90 Elbows Venting with three 90 elbows Venting with three 90 elbows Installing Vent Components Attach the First Vent Component to the Starting CollarsInstall Support Brackets Continue Adding Vent ComponentsAttic Firestop Positioned SO That the Arrow is Pointing UPVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceGas Control System Fireplace Junction BOX in a IPI SystemGas Supply Line Gas Pressure RequirementsAppliance Requirements Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Fan Wiring Diagram Optional Accessories Wall Switch Corner fan locationHearth Extensions FinishingANY Manner Installing Trim, Logs & Ember Material Using a 5/16 nut driver remove the two bolts see Figure Placing the Ember MaterialBefore Lighting the Fireplace After the InstallationDouble-check for faulty components Lighting the FireplaceFireplace Maintenance Important Turn OFF the GAS Before Servicing Your Fireplace

RCOR-HVB-IPI, LCOR-HVB-IPI specifications

Hearth and Home Technologies has established itself as a leading name in the hearth and home industry, providing innovative and high-performance heating solutions. Two standout products from their extensive lineup are the LCOR-HVB-IPI and RCOR-HVB-IPI. Both units exemplify the company's commitment to quality craftsmanship, modern technology, and energy efficiency.

The LCOR-HVB-IPI, an attractive linear model, is designed to bring elegance and warmth to any living space. Its sleek design boasts a contemporary aesthetic, making it a perfect centerpiece for modern homes. One of the main features of the LCOR-HVB-IPI is its impressive heat output capability, ensuring that even the coldest days are comfortably warm. The unit can be controlled via a remote, allowing users to set the desired temperature with ease.

In terms of technology, the LCOR-HVB-IPI employs a sophisticated direct vent system which ensures safe and efficient combustion. This feature not only enhances the overall performance of the unit but also provides peace of mind, knowing that harmful gases are vented outside effectively. The unit is equipped with an IPI (Intermittent Pilot Ignition) system, which allows for energy savings by eliminating the need for a constantly burning pilot light.

On the other hand, the RCOR-HVB-IPI shares many of the same features but is crafted as a traditional-style fireplace. With its charming design, the RCOR-HVB-IPI integrates seamlessly into classic home decor while providing the latest in heating technology. This model also prioritizes energy efficiency, utilizing a similar direct vent system for safe operation and optimized heating.

Both models feature glass doors that provide an unobstructed view of the flames, adding to the ambience of the room. User-friendly controls make it simple to adjust settings, and the option to customize the fire media further enhances the aesthetic appeal.

Additionally, both the LCOR-HVB-IPI and RCOR-HVB-IPI are designed with environmental considerations in mind. Their high-efficiency ratings ensure that they meet or exceed industry standards for emissions, contributing to cleaner indoor air quality.

In summary, Hearth and Home Technologies’ LCOR-HVB-IPI and RCOR-HVB-IPI models are perfect examples of how modern innovation can blend with classic designs to create efficient, stylish heating solutions. Whether you're looking for a contemporary linear model or a traditional fireplace design, these units offer the best of both worlds, ensuring that your home remains warm and inviting throughout the year.