Hearth and Home Technologies RCOR-HVB-IPI, LCOR-HVB-IPI owner manual Safety and Warning Information

Page 2

Safety and Warning Information

READ and UNDERSTAND all instructions carefully

!before starting the installation. FAILURE TO FOLLOW these installation instructions may result in a possible fire hazard and will void the warranty.

!Prior to the first firing of the fireplace, READ the Using Your Fireplace section of the Owners Guide.

DO NOT USE this appliance if any part has been

!under water. Immediately CALL a qualified service technician to inspect the unit and to replace any part of the control system and any gas control which has been under water.

!THIS UNIT IS NOT FOR USE WITH SOLID FUEL. Installation and repair should be PERFORMED by a

!qualified service person. The appliance and venting system should be INSPECTED before initial use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is IMPERATIVE that the unit’s control compartment, burners, and circulating air passageways BE KEPT CLEAN to provide for adequate combustion and ventilation air.

Always KEEP the appliance clear and free from

!combustible materials, gasoline, and other flammable vapors and liquids.

!NEVER OBSTRUCT the flow of combustion and ventilation air. Keep the front of the appliance CLEAR of all obstacles and materials for servicing and proper operations.

Due to the high temperature, the appliance should

!be LOCATED out of traffic areas and away from furniture and draperies. Clothing or flammable material SHOULD NOT BE PLACED on or near the appliance.

!Children and adults should be ALERTED to the hazards of high surface temperature and should STAY AWAY to avoid burns or clothing ignition. Young children should be CAREFULLY SUPERVISED when they are in the same room as the appliance.

These units MUST use one of the vent systems

!described in the Installing the Fireplace section of the Installers Guide. NO OTHER vent systems or components MAY BE USED.

This gas fireplace and vent assembly MUST be

!vented directly to the outside and MUST NEVER be attached to a chimney serving a separate solid fuel burning appliance. Each gas appliance MUST USE a separate vent system. Common vent systems are

PROHIBITED.

INSPECT the external vent cap on a regular basis to

!make sure that no debris is interfering with the air flow.

!The glass door assembly MUST be in place and sealed, and the trim door assembly MUST be in place on the fireplace before the unit can be placed into safe operation.

DO NOT OPERATE this appliance with the glass

!door removed, cracked, or broken. Replacement of the glass door should be performed by a licensed or qualified service person. DO NOT strike or slam the glass door.

!The glass door assembly SHALL ONLY be replaced as a complete unit, as supplied by the gas fireplace manufacturer. NO SUBSTITUTE material may be used.

!DO NOT USE abrasive cleaners on the glass door assembly. DO NOT ATTEMPT to clean the glass door when it is hot.

Turn off the gas before servicing this appliance. It is

!recommended that a qualified service technician perform an appliance check-up at the beginning of each heating season.

!Any safety screen or guard removed for servicing must be replaced before operating this appliance.

!DO NOT place furniture or any other combustible household objects within 36 inches of the fireplace front.

2

Image 2
Contents ST-HVB-IPI LCOR-HVB-IPI RCOR-HVB-IPI What to do if you smell gasSafety and Warning Information Table of Contents Pier-HVB-IPI NG, LP Exploded Parts Diagram / Vue éclatée des pièces PIER-HVB-IPIST-HVB-IPI ST-HVB-IPI LCOR-HVB-IPI LCOR-HVB-IPI RCOR-HVB-IPI RCOR-HVB-IPI PIER-HVB-IPI, ST-HVB-IPI L&RCOR-HVB-IPI Appliance Certification Installation CodesHigh Altitude Installations CertificationANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Fireplaces Diagram of the PIER-HVB-IPI Diagram of the ST-HVB-IPI Diagram of the LCOR-HVB-IPI and RCOR-HVB-IPI 121mmFraming the Fireplace Fireplace Dimensions and LocationsLocating the Fireplace Clearance RequirementsModel AT Each Joint Tems or Components MAY be Used Installing the Vent SystemVent System Approvals Identifying Vent ComponentsStraight OUT Straight UP Vertical VentingMAX .2 M Max. Run 24 610 mmVenting with One 90 Elbow Venting with Two 90 Elbows Venting with Two 90 Elbows Venting with three 90 elbows Venting with three 90 elbows Installing Vent Components Attach the First Vent Component to the Starting CollarsInstall Support Brackets Continue Adding Vent ComponentsAttic Firestop Positioned SO That the Arrow is Pointing UPVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Securing of a Fireplace Positioning, Leveling, and Securing the FireplaceGas Control System Fireplace Junction BOX in a IPI SystemGas Supply Line Gas Pressure RequirementsAppliance Requirements Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Fan Wiring Diagram Optional Accessories Wall Switch Corner fan locationHearth Extensions FinishingANY Manner Installing Trim, Logs & Ember Material Using a 5/16 nut driver remove the two bolts see Figure Placing the Ember MaterialBefore Lighting the Fireplace After the InstallationDouble-check for faulty components Lighting the FireplaceFireplace Maintenance Important Turn OFF the GAS Before Servicing Your Fireplace

RCOR-HVB-IPI, LCOR-HVB-IPI specifications

Hearth and Home Technologies has established itself as a leading name in the hearth and home industry, providing innovative and high-performance heating solutions. Two standout products from their extensive lineup are the LCOR-HVB-IPI and RCOR-HVB-IPI. Both units exemplify the company's commitment to quality craftsmanship, modern technology, and energy efficiency.

The LCOR-HVB-IPI, an attractive linear model, is designed to bring elegance and warmth to any living space. Its sleek design boasts a contemporary aesthetic, making it a perfect centerpiece for modern homes. One of the main features of the LCOR-HVB-IPI is its impressive heat output capability, ensuring that even the coldest days are comfortably warm. The unit can be controlled via a remote, allowing users to set the desired temperature with ease.

In terms of technology, the LCOR-HVB-IPI employs a sophisticated direct vent system which ensures safe and efficient combustion. This feature not only enhances the overall performance of the unit but also provides peace of mind, knowing that harmful gases are vented outside effectively. The unit is equipped with an IPI (Intermittent Pilot Ignition) system, which allows for energy savings by eliminating the need for a constantly burning pilot light.

On the other hand, the RCOR-HVB-IPI shares many of the same features but is crafted as a traditional-style fireplace. With its charming design, the RCOR-HVB-IPI integrates seamlessly into classic home decor while providing the latest in heating technology. This model also prioritizes energy efficiency, utilizing a similar direct vent system for safe operation and optimized heating.

Both models feature glass doors that provide an unobstructed view of the flames, adding to the ambience of the room. User-friendly controls make it simple to adjust settings, and the option to customize the fire media further enhances the aesthetic appeal.

Additionally, both the LCOR-HVB-IPI and RCOR-HVB-IPI are designed with environmental considerations in mind. Their high-efficiency ratings ensure that they meet or exceed industry standards for emissions, contributing to cleaner indoor air quality.

In summary, Hearth and Home Technologies’ LCOR-HVB-IPI and RCOR-HVB-IPI models are perfect examples of how modern innovation can blend with classic designs to create efficient, stylish heating solutions. Whether you're looking for a contemporary linear model or a traditional fireplace design, these units offer the best of both worlds, ensuring that your home remains warm and inviting throughout the year.