Hearth and Home Technologies LCOR-HVB-IPI, RCOR-HVB-IPI owner manual Fireplace Maintenance

Page 41

4Maintaining and Servicing Your Fireplace

Fireplace Maintenance

Although the frequency of your fireplace servicing and main- tenance will depend on use and the type of installation, you should have a qualified service technician perform an appli- ance check-up at the beginning of each heating season. See the table below for specific guidelines regarding each fireplace maintenance task.

IMPORTANT: TURN OFF THE GAS BEFORE SERVICING YOUR FIREPLACE.

Replacing old ember material

Frequency: Once annually, during the checkup.

By: Qualified service technician.

Task: Brush away loose ember material near the burner. Replace old ember material with new dime-size and shape pieces of Golden Ember (GE-93) and Glowing Ember (050- 721). New ember material should be placed alternately on top of the burner - a layer of Golden Ember, a layer of Glowing Ember, and so on. Save the remaining ember material and repeat this procedure at your next servicing. For more information, see Placing Ember Material.

Cleaning Burner and Controls Frequency: Once annually. By: Qualified service technician.

Task: Brush or vacuum the control compartment, fireplace logs and burner areas surrounding the logs.

Cleaning Flame Sensor Rod (IPI Systems)

Frequency: Periodically.

By: Qualified service technician.

Task: Make a visual check of the straight flame sensor rod. Use emery cloth to carefully remove any existing white film or deposits.

Checking Flame Patterns, Flame Height

Frequency: Periodically.

By: Qualified service technician/Home owner.

Task: Make a visual check of your fireplace’s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 48. The flame sensor (IPI) tips should be covered with flame. See Figure 32.

MAKE SURE THE FLAMES

ARE STEADY—NOT

LIFTING OR FLOATING.

Figure 48. Burner Flame Patterns

Checking Vent System

Frequency: Before initial use and at least annually thereafter, more frequently if possible.

By: Qualified service technician/Home owner.

Task: Inspect the external vent cap on a regular basis to ensure that no debris is interfering with the flow of air. Inspect entire vent system for proper function.

Cleaning Glass Door

Frequency: After the first 3 to 4 hours of use. As neces- sary after initial cleaning.

By: Home owner.

Task: Remove and clean glass after the first 3 to 4 hours of use. After the initial cleaning, clean as necessary, particu- larly after adding new ember (flame colorant) material. Film deposits on the inside of the glass door should be cleaned off using a household glass cleaner. NOTE: DO NOT handle or attempt to clean the door when it is hot and DO NOT use abrasive cleaners.

41

Image 41
Contents What to do if you smell gas ST-HVB-IPI LCOR-HVB-IPI RCOR-HVB-IPISafety and Warning Information Table of Contents Pier-HVB-IPI PIER-HVB-IPI NG, LP Exploded Parts Diagram / Vue éclatée des piècesST-HVB-IPI ST-HVB-IPI LCOR-HVB-IPI LCOR-HVB-IPI RCOR-HVB-IPI RCOR-HVB-IPI PIER-HVB-IPI, ST-HVB-IPI L&RCOR-HVB-IPI High Altitude Installations Installation CodesAppliance Certification CertificationANY Such Action MAY Possibly Cause a Fire Hazard Pre-install PreparationIntroducing the Heat & Glo Gas Fireplaces Diagram of the PIER-HVB-IPI Diagram of the ST-HVB-IPI 121mm Diagram of the LCOR-HVB-IPI and RCOR-HVB-IPILocating the Fireplace Fireplace Dimensions and LocationsFraming the Fireplace Clearance RequirementsModel AT Each Joint Vent System Approvals Installing the Vent SystemTems or Components MAY be Used Identifying Vent ComponentsMAX .2 M Straight UP Vertical VentingStraight OUT Max. Run 24 610 mmVenting with One 90 Elbow Venting with Two 90 Elbows Venting with Two 90 Elbows Venting with three 90 elbows Venting with three 90 elbows Attach the First Vent Component to the Starting Collars Installing Vent ComponentsContinue Adding Vent Components Install Support BracketsPositioned SO That the Arrow is Pointing UP Attic FirestopVent Termination Minimum Clearances Minimum Height from Roof to Lowest Discharge Opening Gas Control System Positioning, Leveling, and Securing the FireplaceSecuring of a Fireplace Fireplace Junction BOX in a IPI SystemGas Pressure Requirements Gas Supply LineAppliance Requirements Wiring the Fireplace For Intermittent Pilot Ignition WiringOperation using Battery Power Corner fan location Fan Wiring Diagram Optional Accessories Wall SwitchHearth Extensions FinishingANY Manner Installing Trim, Logs & Ember Material Placing the Ember Material Using a 5/16 nut driver remove the two bolts see FigureDouble-check for faulty components After the InstallationBefore Lighting the Fireplace Lighting the FireplaceImportant Turn OFF the GAS Before Servicing Your Fireplace Fireplace Maintenance