Hearth and Home Technologies NorthStar-NT, NorthStar-GT Care and Cleaning of Plated Surfaces

Page 61

D. Care and Cleaning of Plated Surfaces

Clean-plated surfaces with vinegar or a glass cleaner before lighting your first fire to prevent permanent staining.

CAUTION

Clean all the fingerprints and oils from the surface before fir- ing the appliance for the first time.

Use a glass cleaner or vinegar and towel to remove the oils.

Oils can cause permanent markings on plating, if not removed.

After plating is cured, oils will not affect the finish.

CAUTION

Do not use polishes with abrasives. It will scratch plated surfaces.

E. Maintenance Task List

Inspect

 

Maintenance Tasks

 

 

 

Screens

1.

Assess condition of screen and replace as necessary.

 

 

 

 

2.

Verify maintenance of proper clearance to combustible household objects.

 

 

 

Glass Doors

1.

Inspect glass panels for cracks. Replace if this condition is present.

 

 

 

 

2.

Confirm there is no damage to glass or glass frame. Replace as necessary.

 

 

 

 

3.

Inspect door rope. Confirm glass does not move around in glass frame

 

 

 

 

4.

Clean glass using a non-abrasive cleaner.

 

 

 

Door Rope

1.

Open door, place half of dollar bill inside, and close door.

(Dollar Bill Test)

 

 

2.

Attempt to pull the bill out.

 

 

 

 

 

3.

If the bill gives good resistance or is not removable, the rope is adjusted correctly.

 

 

If the bill comes out too easily, the door rope needs adjustment to create an even thickness all the way around door.

 

 

 

Circulation Compartment

1.

Remove any foreign objects.

 

 

 

 

2.

Verify unobstructed air circulation.

 

 

 

Firebox

1.

Inspect condition of brick. Replace if crumbly, deteriorated, or if cracks exceed 1/4 in. (6 mm).

 

 

 

Chimney

1.

Inspect for blockage or obstruction such as bird nests, leaves, etc.

 

 

 

 

2.

Confirm that termination cap remains clear and unobstructed by plants, etc.

 

 

 

 

3.

Verify that termination cap clearance to subsequent construction (building additions) has been maintained.

 

 

 

 

4.

Inspect for corrosion or separation.

 

 

 

 

5.

Verify weather stripping, sealing and flashing remain intact.

 

 

 

 

6.

Inspect for creosote and remove as needed. (See Section 11)

 

 

 

September 1, 2008

Heat & Glo • NorthStar EPA Fireplace • 480-1081C

Page 61

Image 61
Contents Hot glass will cause burns Installation and OperationFire Risk Serial No Model Name Test Lab Report No Manufactured Date 007Table of Contents Appliance Certification Listing and Code ApprovalsMobile Home Approved BTU & Efficiency Specifications Glass SpecificationsGetting Started Design and Installation ConsiderationsNegative Pressure Asphyxiation RiskSeptember 1 Heat & Glo NorthStar EPA Fireplace 480-1081C Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesModel #NorthStar Clearances to Combustible Materials ClearancesMinimum Clearances to Combustibles Frame the FireplaceOptional Framing Construction / Reduced Mantel Height Non-Combustible MaterialsSuggestions Electrical Access and Wiring DiagramMaterials Construct the ChaseInstall the Outside Air Kit Installation of FireplaceRisk of Smoke Spillage Fire Risk Asphyxiation RiskHandle Left Closed Handle Right OpenPosition the Fireplace Secure the FireplacePlace the Protective Metal Hearth Strips Position the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ReturnsAssemble the Chimney Sections Installing CAK4A and Flex PipeAssembling Chimney Sections for the SL- 300 Series Installing Flex Pipe Install the Ceiling FirestopsDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney Chimney Termination 2-10-3 Rule Complete the EnclosureChimney Termination Requirements See Figures 25.1 Slanted RoofsInstall the Chimney Air Kit required in Canada Install the Roof FlashingMark the Exit Point of the Roof Cut Out the Hole in the RoofConsult local codes for framing details SL-300 Series Ceiling/Roof ThimbleChase Top Install the Termination CapChase Top Framing ‑1/2 in mm below the chase top. See Figure Fan Replacement AccessoriesDoor and Door Gasket Baffle Removal and InstallationMinimum Clearance to Combustibles Heat Zone Kit20 ft 3 6m 10 ft 1 3m No cut needed Run Length Cut Pipe Ft 6-12m4 wall Timer Assembly Timer Assembly ReplacementRemove & Replace Timer Exploded View of Entire Assembly for Point of Reference only Hearth Extension FinishingCalculating Alternate Floor Protection Material Positioning the Protective Metal Hearth Strips Model # NorthStarFascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Risk of Fire Non-Combustible Facing Material InstallationMantel Mantel SpecificationsOperating Instructions Symptoms of Over-FiringOver-Firing Your Appliance General InformationKeep open during use Outside AirFirescreen Clear Space Near the FireplaceGlass Doors Fan OperationWood Fuel Hardwood vs. Softwood Moisture contentSeasoning Starting a Fire Storing WoodFire Risk Incorrect Positions Correct Baffle & Blanket PlacementAutomatic Combustion Control ACC Burning ProcessBurn Rates Burning GuidelinesOpacity Burn Rate BTU / Hr Slide Air ControlChimney Fire Fire SafetyUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? General Maintenance Maintenance and Servicing the FireplaceClean Creosote Chimney CleaningGlass Cleaning Glass ReplacementDisposal of Ashes Fire Risk Injury RiskFirebrick Replacement Maintenance Task List Care and Cleaning of Plated SurfacesInspect Maintenance Tasks Date of Service Performed By Description of Service Service And Maintenance LogReference Materials Fireplace DimensionsNorthStar Chimney Components 15-3/4 NorthStar Fireplace Diagram Parts DiagramNorthStar FP Service Parts and AccessoriesDescription Comments Serial Number Date Stocked Depot Service Parts Alpabetical OrderAccessories CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Woodburning Fireplace NorthStar EPA CertifiedContact Information Dealer Telephone

NorthStar-GT, NorthStar-BK, NorthStar-NT specifications

Hearth and Home Technologies has established itself as a leader in the production of innovative heating appliances, particularly with the launch of its NorthStar series: NorthStar-NT, NorthStar-BK, and NorthStar-GT. These models are designed to deliver superior performance, aesthetic appeal, and advanced technology, making them an excellent choice for modern homes.

The NorthStar-NT model is ideally suited for those seeking a reliable and efficient heating solution. It boasts a powerful, advanced heating technology that maximizes heat output while minimizing fuel consumption. The NorthStar-NT employs a unique combustion system that ensures a cleaner burn, resulting in fewer emissions and a lower environmental impact. The sleek design of the NorthStar-NT allows it to blend seamlessly into any room, making it not just a heating unit but also an attractive focal point.

On the other hand, the NorthStar-BK variant stands out for its versatility and aesthetic flexibility. It offers an array of customizable options, enabling homeowners to match the unit's appearance with their interior decor. The NorthStar-BK features a large viewing area, which enhances the visual appeal of the flames while providing efficient heat distribution. This model incorporates user-friendly controls that allow for easy temperature adjustments, ensuring that comfort is just a button away.

The NorthStar-GT model elevates the heating experience with its advanced smart technology features. Equipped with Wi-Fi connectivity, the NorthStar-GT allows users to control the appliance remotely via a smartphone app. This model also supports voice-activated commands, integrating seamlessly with smart home systems. The NorthStar-GT emphasizes energy efficiency, with programmable settings that enable users to optimize heating schedules to their lifestyle, ultimately contributing to energy savings.

All three NorthStar models feature durable construction and high-quality materials designed to withstand years of use. Their construction ensures not only longevity but also safety, with multiple safety features integrated into each model. Easy maintenance and cleaning options further enhance their user-friendly design.

In summary, the Hearth and Home Technologies NorthStar series including the NorthStar-NT, NorthStar-BK, and NorthStar-GT brings together cutting-edge technology, unparalleled efficiency, and stunning aesthetics. Each model caters to different needs, ensuring that homeowners can find the perfect heating solution that fits their style and requirements.