Hearth and Home Technologies NorthStar-NT, NorthStar-GT owner manual Assemble the Chimney Sections

Page 22

D. Assemble the Chimney Sections

Attach either a straight chimney section or an offset to the top of the fireplace (depending on your installation require- ment). Chimney sections are locked together by pushing downward until the top section meets the stop bead on the lower section.

The inner flue is placed to the inside of the flue section below it. The outer casing is placed outside the outer casing of the chimney section below it. See Figure 22.1.

If you are using a different approved venting system, follow the instructions that were supplied with that system.

Figure 22.1 Assembling Chimney Sections

Note: Inner flue and outer liner sections cannot be disassembled once locked together. Plan ahead to ensure the proper installation height is achieved with the selected chimney components.

WARNING

Fire Risk

Do NOT install substitute or damaged chimney components.

MUST use chimney system described in this manual.

NO OTHER chimney components may be used.

Substitute or damaged chimney components may impair safe operation.

E. Assembling Chimney Sections for the SL- 300 Series

NOTE: Chimney Air Kit, Part CAK4A is required when using the SL-300 Pipe Series. Detailed instruc- tions are supplied with the kit.

Installing CAK4A and Flex Pipe

NOTE: FOLLOW DETAILED INSTRUCTIONS THAT COME WITH THE CAK4A.

1.Install the chimney pipe first.

2.Hand bend the tabs in position before placing on the fireplace.

3.Place the box on top of the fireplace around the chimney pipe, push both pieces together and secure with screws provided.

4.Use the pre-punched holes in the tabs as guides and drill holes through the fireplace top.

5.Secure the CAK4A in place.

6.Seal around the kit at the flue and at the top of the can with caulk.

Attach

Flue First

Secure with Screws

Provided

CAK4A

Push Together

Secure to Top

Figure 22.2 Installing the CAK4A

NOTES:

1.The outside termination cap must be a minimum of 6 ft (1829 mm) above the ground and kept free of debris.

2.If the CAK4A is installed in a chase, the CAK4A side termination cap must be at least 3 ft (914 mm) below the chimney top.

3.Seal around the cap and flex with caulk to stop air from getting in to the chase (See Figure 23.1 on page 23).

WARNING

Fire Risk

The flex hose must never be compressed or deformed!

Page 22

Heat & Glo • NorthStar EPA Fireplace • 480-1081C

September 1, 2008

Image 22
Contents Hot glass will cause burns Installation and OperationFire Risk 007 Serial No Model Name Test Lab Report No Manufactured DateTable of Contents Appliance Certification Listing and Code ApprovalsMobile Home Approved Glass Specifications BTU & Efficiency SpecificationsNegative Pressure Design and Installation ConsiderationsGetting Started Asphyxiation RiskSeptember 1 Heat & Glo NorthStar EPA Fireplace 480-1081C Typical Fireplace System Typical Fireplace SystemInspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesModel #NorthStar Clearances Clearances to Combustible MaterialsOptional Framing Construction / Reduced Mantel Height Frame the FireplaceMinimum Clearances to Combustibles Non-Combustible MaterialsElectrical Access and Wiring Diagram SuggestionsConstruct the Chase MaterialsInstallation of Fireplace Install the Outside Air KitHandle Left Closed Fire Risk Asphyxiation RiskRisk of Smoke Spillage Handle Right OpenPosition the Fireplace Secure the FireplacePlace the Protective Metal Hearth Strips Level the Fireplace Position the Protective Metal Hearth StripsChimney Assembly Chimney Requirements Chimney Termination RequirementsUsing Offsets/Returns ExampleAssemble the Chimney Sections Installing CAK4A and Flex PipeAssembling Chimney Sections for the SL- 300 Series Install the Ceiling Firestops Installing Flex PipeDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney Chimney Termination Requirements See Figures 25.1 Complete the EnclosureChimney Termination 2-10-3 Rule Slanted RoofsMark the Exit Point of the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Cut Out the Hole in the RoofSL-300 Series Ceiling/Roof Thimble Consult local codes for framing detailsChase Top Install the Termination CapChase Top Framing ‑1/2 in mm below the chase top. See Figure Accessories Fan ReplacementBaffle Removal and Installation Door and Door GasketHeat Zone Kit Minimum Clearance to CombustiblesRun Length Cut Pipe Ft 6-12m 20 ft 3 6m 10 ft 1 3m No cut needed4 wall Timer Assembly Replacement Timer AssemblyRemove & Replace Timer Exploded View of Entire Assembly for Point of Reference only Hearth Extension FinishingCalculating Alternate Floor Protection Material Model # NorthStar Positioning the Protective Metal Hearth StripsFascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Non-Combustible Facing Material Installation Risk of FireMantel Specifications MantelOver-Firing Your Appliance Symptoms of Over-FiringOperating Instructions General InformationOutside Air Keep open during useGlass Doors Clear Space Near the FireplaceFirescreen Fan OperationWood Fuel Hardwood vs. Softwood Moisture contentSeasoning Storing Wood Starting a FireFire Risk Correct Baffle & Blanket Placement Incorrect PositionsBurning Process Automatic Combustion Control ACCOpacity Burning GuidelinesBurn Rates Burn Rate BTU / Hr Slide Air ControlFire Safety Chimney FireUnderstanding Vent Problems TroubleshootingDraft Problems Factory-built Fireplaces Troubleshooting Diagnostics and Problem Solving Diagnostic Question Possible Causes of Condition SolutionsDon’t get enough/any heat. What can I do about it? Clean Maintenance and Servicing the FireplaceGeneral Maintenance Creosote Chimney CleaningDisposal of Ashes Glass ReplacementGlass Cleaning Fire Risk Injury RiskFirebrick Replacement Maintenance Task List Care and Cleaning of Plated SurfacesInspect Maintenance Tasks Service And Maintenance Log Date of Service Performed By Description of ServiceReference Materials Fireplace DimensionsNorthStar Chimney Components 15-3/4 Parts Diagram NorthStar Fireplace DiagramService Parts and Accessories NorthStar FPService Parts Alpabetical Order Description Comments Serial Number Date Stocked DepotAccessories Warranty Policy Hearth & Home Technologies Limited Warranty CONDITIONS, Exclusions & Limitation of LiabilityHearth & Home Technologies Limited Warranty Cont’d Contact Information NorthStar EPA CertifiedWoodburning Fireplace Dealer Telephone

NorthStar-GT, NorthStar-BK, NorthStar-NT specifications

Hearth and Home Technologies has established itself as a leader in the production of innovative heating appliances, particularly with the launch of its NorthStar series: NorthStar-NT, NorthStar-BK, and NorthStar-GT. These models are designed to deliver superior performance, aesthetic appeal, and advanced technology, making them an excellent choice for modern homes.

The NorthStar-NT model is ideally suited for those seeking a reliable and efficient heating solution. It boasts a powerful, advanced heating technology that maximizes heat output while minimizing fuel consumption. The NorthStar-NT employs a unique combustion system that ensures a cleaner burn, resulting in fewer emissions and a lower environmental impact. The sleek design of the NorthStar-NT allows it to blend seamlessly into any room, making it not just a heating unit but also an attractive focal point.

On the other hand, the NorthStar-BK variant stands out for its versatility and aesthetic flexibility. It offers an array of customizable options, enabling homeowners to match the unit's appearance with their interior decor. The NorthStar-BK features a large viewing area, which enhances the visual appeal of the flames while providing efficient heat distribution. This model incorporates user-friendly controls that allow for easy temperature adjustments, ensuring that comfort is just a button away.

The NorthStar-GT model elevates the heating experience with its advanced smart technology features. Equipped with Wi-Fi connectivity, the NorthStar-GT allows users to control the appliance remotely via a smartphone app. This model also supports voice-activated commands, integrating seamlessly with smart home systems. The NorthStar-GT emphasizes energy efficiency, with programmable settings that enable users to optimize heating schedules to their lifestyle, ultimately contributing to energy savings.

All three NorthStar models feature durable construction and high-quality materials designed to withstand years of use. Their construction ensures not only longevity but also safety, with multiple safety features integrated into each model. Easy maintenance and cleaning options further enhance their user-friendly design.

In summary, the Hearth and Home Technologies NorthStar series including the NorthStar-NT, NorthStar-BK, and NorthStar-GT brings together cutting-edge technology, unparalleled efficiency, and stunning aesthetics. Each model caters to different needs, ensuring that homeowners can find the perfect heating solution that fits their style and requirements.