Hearth and Home Technologies NorthStar-BK Hearth & Home Technologies Limited Warranty Cont’d

Page 71

Hearth & Home Technologies LIMITED WARRANTY (Cont’d)

HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main- tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing agent identification label furnished with the appliance; (2) installation which does not comply with local building codes;

(3) shipping, improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environ- mental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure or handling devices such as exhaust fans or forced air furnaces or other such causes; (5) use of fuels other than those specified in the operating instructions; (6) installation or use of components not supplied with the appliance or any other compo- nents not expressly authorized and approved by HHT; and/or (7) modification of the appliance not expressly autho- rized and approved by HHT in writing.

This warranty does not apply to non-HHT venting components, hearth components or other accessories used in con- junction with the installation of this product.

This warranty is void if the appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation, or there is any damage to the appliance or other components due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation.

HHT’s liability under this warranty is limited to the replacement and repair of defective components or workmanship during the applicable period. HHT may fully discharge all of its obligations under such warranties by repairing the defective component(s) at HHT’s discretion. Shipping costs are not covered under this warranty.

Some states do not allow exclusions or limitation of incidental or consequential damages, so those limitations may not apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state.

EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE WARRANTY SPECIFIED ABOVE.

This Limited Warranty is effective on all HHT appliances sold after September 01, 2008 and supersedes any and all war- ranties currently in existence.

If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide neces- sary parts or components, contact the nearest authorized HHT dealer or supplier.

4021-645A 09-01-08

September 1, 2008

Heat & Glo • NorthStar EPA Fireplace • 480-1081C

Page 71

Image 71
Contents Fire Risk Installation and OperationHot glass will cause burns Serial No Model Name Test Lab Report No Manufactured Date 007Table of Contents Mobile Home Approved Listing and Code ApprovalsAppliance Certification BTU & Efficiency Specifications Glass SpecificationsAsphyxiation Risk Design and Installation ConsiderationsGetting Started Negative PressureSeptember 1 Heat & Glo NorthStar EPA Fireplace 480-1081C Typical Fireplace System Typical Fireplace SystemFire Risk Explosion Risk Tools and Supplies NeededInspect Fireplace and Components Model #NorthStar Framing and ClearancesSelecting Fireplace Location Clearances to Combustible Materials ClearancesNon-Combustible Materials Frame the FireplaceMinimum Clearances to Combustibles Optional Framing Construction / Reduced Mantel HeightSuggestions Electrical Access and Wiring DiagramMaterials Construct the ChaseInstall the Outside Air Kit Installation of FireplaceHandle Right Open Fire Risk Asphyxiation RiskRisk of Smoke Spillage Handle Left ClosedPlace the Protective Metal Hearth Strips Secure the FireplacePosition the Fireplace Position the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Chimney Termination Requirements Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections for the SL- 300 Series Installing CAK4A and Flex PipeAssemble the Chimney Sections Installing Flex Pipe Install the Ceiling FirestopsSecure the Chimney Install the Attic Insulation ShieldDouble-check the Chimney Assembly Slanted Roofs Complete the EnclosureChimney Termination 2-10-3 Rule Chimney Termination Requirements See Figures 25.1Cut Out the Hole in the Roof Install the Roof FlashingInstall the Chimney Air Kit required in Canada Mark the Exit Point of the RoofConsult local codes for framing details SL-300 Series Ceiling/Roof ThimbleChase Top Framing Install the Termination CapChase Top ‑1/2 in mm below the chase top. See Figure Fan Replacement AccessoriesDoor and Door Gasket Baffle Removal and InstallationMinimum Clearance to Combustibles Heat Zone Kit20 ft 3 6m 10 ft 1 3m No cut needed Run Length Cut Pipe Ft 6-12m4 wall Timer Assembly Timer Assembly ReplacementRemove & Replace Timer Exploded View of Entire Assembly for Point of Reference only Calculating Alternate Floor Protection Material FinishingHearth Extension Positioning the Protective Metal Hearth Strips Model # NorthStarFascia Outer Tile or Marble Combustible Can Flange Floor Position the Hearth Extension Finishing Material Risk of Fire Non-Combustible Facing Material InstallationMantel Mantel SpecificationsGeneral Information Symptoms of Over-FiringOperating Instructions Over-Firing Your ApplianceKeep open during use Outside AirFan Operation Clear Space Near the FireplaceFirescreen Glass DoorsSeasoning Moisture contentWood Fuel Hardwood vs. Softwood Starting a Fire Storing WoodFire Risk Incorrect Positions Correct Baffle & Blanket PlacementAutomatic Combustion Control ACC Burning ProcessBurn Rate BTU / Hr Slide Air Control Burning GuidelinesBurn Rates OpacityChimney Fire Fire SafetyDraft Problems TroubleshootingUnderstanding Vent Problems Factory-built Fireplaces Troubleshooting Diagnostic Question Possible Causes of Condition Solutions Diagnostics and Problem SolvingDon’t get enough/any heat. What can I do about it? Creosote Chimney Cleaning Maintenance and Servicing the FireplaceGeneral Maintenance CleanFire Risk Injury Risk Glass ReplacementGlass Cleaning Disposal of AshesFirebrick Replacement Inspect Maintenance Tasks Care and Cleaning of Plated SurfacesMaintenance Task List Date of Service Performed By Description of Service Service And Maintenance LogNorthStar Fireplace DimensionsReference Materials Chimney Components 15-3/4 NorthStar Fireplace Diagram Parts DiagramNorthStar FP Service Parts and AccessoriesDescription Comments Serial Number Date Stocked Depot Service Parts Alpabetical OrderAccessories CONDITIONS, Exclusions & Limitation of Liability Warranty Policy Hearth & Home Technologies Limited WarrantyHearth & Home Technologies Limited Warranty Cont’d Dealer Telephone NorthStar EPA CertifiedWoodburning Fireplace Contact Information

NorthStar-GT, NorthStar-BK, NorthStar-NT specifications

Hearth and Home Technologies has established itself as a leader in the production of innovative heating appliances, particularly with the launch of its NorthStar series: NorthStar-NT, NorthStar-BK, and NorthStar-GT. These models are designed to deliver superior performance, aesthetic appeal, and advanced technology, making them an excellent choice for modern homes.

The NorthStar-NT model is ideally suited for those seeking a reliable and efficient heating solution. It boasts a powerful, advanced heating technology that maximizes heat output while minimizing fuel consumption. The NorthStar-NT employs a unique combustion system that ensures a cleaner burn, resulting in fewer emissions and a lower environmental impact. The sleek design of the NorthStar-NT allows it to blend seamlessly into any room, making it not just a heating unit but also an attractive focal point.

On the other hand, the NorthStar-BK variant stands out for its versatility and aesthetic flexibility. It offers an array of customizable options, enabling homeowners to match the unit's appearance with their interior decor. The NorthStar-BK features a large viewing area, which enhances the visual appeal of the flames while providing efficient heat distribution. This model incorporates user-friendly controls that allow for easy temperature adjustments, ensuring that comfort is just a button away.

The NorthStar-GT model elevates the heating experience with its advanced smart technology features. Equipped with Wi-Fi connectivity, the NorthStar-GT allows users to control the appliance remotely via a smartphone app. This model also supports voice-activated commands, integrating seamlessly with smart home systems. The NorthStar-GT emphasizes energy efficiency, with programmable settings that enable users to optimize heating schedules to their lifestyle, ultimately contributing to energy savings.

All three NorthStar models feature durable construction and high-quality materials designed to withstand years of use. Their construction ensures not only longevity but also safety, with multiple safety features integrated into each model. Easy maintenance and cleaning options further enhance their user-friendly design.

In summary, the Hearth and Home Technologies NorthStar series including the NorthStar-NT, NorthStar-BK, and NorthStar-GT brings together cutting-edge technology, unparalleled efficiency, and stunning aesthetics. Each model caters to different needs, ensuring that homeowners can find the perfect heating solution that fits their style and requirements.