TUCSON Gas-Fired Direct-Vent

PILOT LIGHT WARNING

The Tucson has a piezoelectric spark igniter (the push button located next to the gas control valve behind the valve access door), which ignites the pilot light by means of a spark at the pilot light assembly. Do not attempt to light the unit with a match or by any means than the piezoelectric spark.

PREPARE FOR LIGHTING

Prepare for the lighting procedure by adjusting the thermostat (if equipped) to its lowest setting or OFF position. If the gas control knob is not in the OFF position, turn the knob fully clockwise to OFF. Locate the variable output control knob and turn it fully clockwise to the highest setting.

Prior to lighting the unit for the first time, wait 5 minutes to allow any residual gas within the unit to dissipate. Smell all around the appliance area for gas. Be sure to smell next to the floor because some gases are heavier than air and will settle on the floor. If you do not smell gas after this five-minute period, proceed with the lighting procedure. If you do smell gas, DO NOT proceed with the lighting procedure. Instead, immediately refer to the What To Do If You Smell Gas Warning, on the cover of this manual.

WARNING: The valve control has an interlock device. After shutting off all gas flow, the pilot burner cannot be relit until the thermocouple has cooled, allowing the electromagnet to be released (approx. 60 seconds). The gas control knob is designed to be operated by hand. Do not use any tools during this operation. Damaged knobs may result in serious injury.

INITIAL ADJUSTMENTS

Once the Tucson has been set in place, connected and assembled as described in the Clearances To Combustibles, Venting

Components & Configurations, Electrical Connections, And Gas Supply and Connections sections of this manual, the unit is almost ready to be lit for the first time. The manufacturer tests each unit prior to shipment, so ignition should take place without failure. However, a number of small

adjustments may be necessary to compensate for variations in gas pressure, altitude, and other factors particular to each installation.

VARIABLE OUTPUT CONTROL

The gas control valve is equipped with a variable output control. This control varies the rate of heat produced by the unit by varying the gas pressure to the main burner tube. A combination of heat output and the thermostat setting affect the length of the burn cycle. If your stove turns on and off too often, try, first, reducing the burn cycle by turning the HI/LOW knob, on the control valve, to a lower setting. Using the variable output control, the heat output of the unit can be reduced for mild fall and spring months, or maximized for the colder winter months. This adjustment can be made, by the homeowner, as necessary by turning the variable output control knob to “HI”, “LO” or any setting in between.

AIR SHUTTER

The air shutter is used to regulate the air-to- gas combustion mixture, which in turn influences the size and color of the flames. The air shutter has been positioned in the general location needed for the type of gas being used, however, if the unit is not burning as well as it should, then the air shutter may need adjusting. The air shutter may need adjustment once the unit has been installed to compensate for variations in supply line pressure, restriction plate position, altitude, gas type conversions, and other variables.

32

Image 32
Contents What to do if YOU Smell GAS QUE Faire SI Vous Sentez UNE Odeur DE GAZTucson Model #8700 Information Sheet What WhenIntroduction Safety Information Service Caution Fire HazardMust be Vented to Outside HOT SurfacesDo not Light Pilot or Main Burners by Hand Ceramic Fiber LOG Safety InformationElectrical Hazard Mobile Home Installations Specifications Routine Maintenance and Care CleaningOWNER’S Information Daily OperationFIREBOX, PILOT, & Burner Tubes Pilot Flame PatternClass Cleaning Replace the Front Door Gasket AS NeededINSTALLER’S Information Items Required for InstallationCodes Packing ListUnpacking and Inspection Hearth REQUIREMENT/FLOOR ProtectionClearance to Combustibles Minimum Venting-Mantle Clearance ToSnorkel-Wall Clearance To Combustibles Acceptable Direct-Vent Termination Cap locations Venting Information Venting ConnectionRestriction Plate Position Adjustment to Restriction PlateRestriction Plate Venting Components Configuration Acceptable DIRECT-VENT Termination CAP LocationsApproved Venting System Components Chimney Liner SystemComponents For a Typical Snorkel Installation Clearances from the pipe to combustibles Approved Venting Configuration for Horizontal Termination 90 0 ElbowApproved Configuration for Fireplace Installation Co-Linear & Chimney as Air InletVenting KIT KIT #97-65001 Remote Control Thermostat PlacementThermostat Wiring Electrical ConnectionsWiring Diagram Tucson Wiring InstructionsGAS Supply GAS Supply ConnectionsGAS Connections LOG Placement Installation of the LOG SETRemoval of LOG SET Log SetBREAK-IN Procedure Lighting the Unit for the First TimeSmoke and Fumes Warning BREAK-IN WarningInitial Adjustments Pilot Light WarningPrepare for Lighting Variable Output ControlLighting Instructions AIR Shutter Adjustments To Turn OFF GAS to AppliancePilot Adjustment Burner Flame AppearanceMaintenance Care Cleaning › Warning do not Clean the Unit When IT’S HOTFirebox Pilot & Burner FlamesCleaning the Glass Parts Lists › WarningTroubleshooting Troubleshooting Troubleshooting Limited Lifetime Warranty Limited FIVE-YEAR WarrantyLimited THREE-YEAR Warranty Limited ONE-YEAR WarrantyQualifying for Warranty Coverage ExclusionsWarranty Registration Remedy

Tucson (8700) specifications

Hearth and Home Technologies Tucson (8700) represents a significant advancement in the realm of home heating solutions. This gas fireplace model combines elegant design with cutting-edge technology, providing both aesthetic appeal and functional efficiency. The Tucson is designed to serve as a focal point in any living space while delivering warmth and comfort.

One of the main features of the Tucson (8700) is its sleek, modern design. Available in a variety of finishes, the fireplace fits seamlessly into a range of decor styles, from contemporary to traditional. Its large viewing area provides an unobstructed view of the flames, creating an inviting ambiance. The glass front is both stylish and functional, enhancing the overall appeal while maximizing heat output without compromising safety.

The Tucson is engineered with advanced technology that prioritizes efficiency and convenience. It utilizes a direct vent system, ensuring that the fireplace draws air from the outside and expels exhaust gases efficiently, improving indoor air quality. This feature allows for installations in a variety of locations within the home without the need for traditional chimney systems.

Another notable characteristic is its adjustable flame height and heat output. Homeowners can easily customize the warmth and ambiance to suit their preferences, providing versatile heating options for various occasions. The Tucson includes a remote control feature, allowing users to operate the fireplace without having to leave their comfortable seating area.

Safety is a key consideration in the design of the Tucson (8700). Equipped with an automatic shutoff feature, the fireplace will turn off if it detects any irregularities, ensuring peace of mind for users. The glass front remains cool to the touch, minimizing the risk of burns.

Additionally, the Tucson can be complemented with a variety of decorative options, including log sets and decorative media, allowing homeowners to create a personalized look that matches their style. This flexibility, along with its efficiency and stunning design, makes the Hearth and Home Technologies Tucson (8700) a standout choice for modern homes seeking both beauty and warmth.