Hearth and Home Technologies 42H-B, 42-B owner manual Parts List, Service

Page 30

30

Service Parts

DAKOTA42-B, DAKOTA42H-B

Service Parts Diagram

Beginning Manufacturing Date: Feb 2006

42 in. Outdoor Gas Fireplace

Ending Manufacturing Date: Active

 

Service Parts

DAKOTA42-B, DAKOTA42H-B

 

Service Parts List

Beginning Manufacturing Date: Feb 2006

 

42 in. Outdoor Gas Fireplace

 

Ending Manufacturing Date: Active

IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for

 

 

 

Stocked

your appliance please provide model number and serial number. All parts listed in this manual may

 

be ordered from an authorized dealer.

 

 

 

B. Service

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B

1

2

3

4

5

6

Post Serial #OD9288

7

8

9

6

5

7

8

9

10

 

 

11

 

 

 

Pre Serial #OD9288

12

 

13

 

 

14

18

 

 

15

 

19

16

20

 

17

21

22

29 30

28

23

 

 

 

 

at Depot

ITEM

DESCRIPTION

COMMENTS

PART NUMBER

 

1

ON/OFF Valve

 

15697

Y

2

3/8 Swivel Nut Connector

 

4021-561

 

 

 

 

 

 

3

Brass Elbow

 

4021-098

 

 

 

 

 

 

4

Valve NG

 

593-500

Y

 

 

 

 

Valve LP

 

593-501

Y

 

 

 

 

 

 

 

5

Brass Fitting (1/2-3/8)

 

19641

 

 

 

 

 

 

6

Flex Burner Line Kit

Post SN #OD9287

SRV4036-260

 

 

 

 

 

 

7

Compression Nut

 

32553

 

 

 

 

 

 

8

Burner Orifice NG

 

4021-134

Y

 

 

 

 

Burner Orifice LP

 

32562

Y

 

 

 

 

 

 

 

9

Jam Nut (1/2-20)

 

32563

 

 

 

 

 

 

10

3/8 in. NPT Pipe Coupler

Pre SN #OD9288

4021-349

 

 

 

 

 

 

11

3/8 Male NPT x 4-1/2 in. Pipe

Pre SN #OD9288

4021-348

 

 

 

 

 

 

12

3/8 NPT Street L

Pre SN #OD9288

4021-347

 

 

 

 

 

 

13

Switch Box

 

4021-117

Y

 

 

 

 

 

14

Battery Pack

 

593-594A

Y

 

 

 

 

 

15

Electrical Box Gasket

 

4021-153

 

 

 

 

 

 

16

Switch Cover Plate

 

4036-157

 

 

 

 

 

 

17

ON/OFF Rocker Switch

 

060-511

Y

 

 

 

 

 

 

Switch Box Screw Pack

 

4025-007

 

 

 

 

 

 

18

Valve Assembly Bracket

 

4036-179

 

 

 

 

 

 

19

Control Module

 

593-592

Y

 

 

 

 

 

20

Pilot Assembly NG

 

593-512A

Y

 

 

 

 

Pilot Assembly LP

 

593-513A

Y

 

 

 

 

 

 

 

21

IPI Wiring Harness (w/5 ft. Leads)

 

4021-116

 

 

 

 

 

 

 

Burner Tube Assembly NG

 

4036-068

 

 

 

 

 

 

 

Burner Tube Assembly LP

 

4036-069

 

 

 

 

 

 

22

Pilot Shield

 

4036-248

 

 

 

 

 

 

23

Rock Retainer

 

4036-190

 

 

 

 

 

 

24

Air Shutter

 

4036-194

 

 

 

 

 

 

25

1-1/4 in. Burner Tube NG

 

4036-187

 

 

 

 

 

1-1/4 in. Burner Tube LP

 

4036-188

 

 

 

 

Parts List (continued)

4036-909 • Rev L 10/09

24

 

27

Post Serial #OD9287

 

(Kit is retro-fittable.)

25

26

Part number list on following page.

06/09

26

Burner Tube Bracket

4036-189

 

 

 

Switch Box Assembly

4036-040

 

 

 

 

 

 

 

 

 

Also available:

 

 

 

 

 

 

 

 

 

 

60 in. Flex Line Assembly

 

 

SRV4036-044

 

 

 

 

 

 

 

 

 

27

ON/OFF Valve

 

 

4021-115

 

 

 

 

 

 

 

 

 

28

60 in. Flex Line 5/8 in. dia.

 

 

4021-133

Y

 

 

 

 

 

 

 

29

Coupler - 3/8 Male NPT / 7/8 SAE Flare

 

 

4021-114

 

 

 

 

 

 

 

 

 

30

1/2 in. Male NPT to 3/8 in. Fem. NPT Bush

 

 

4021-030

 

 

Additonal

service parts on following page.

 

 

 

 

 

 

 

 

 

 

06/09

Image 30
Contents This appliance must be installed outside What to do if you smell gasHot glass will cause burns Congratulations Listing Label Information/LocationTable of Contents High Altitude Installations Appliance Certification BTU SpecificationsGlass Specifications Listing and Code ApprovalsDesign and Installation Considerations Getting StartedMoisture Resistance Tools and Supplies Needed Inspect Appliance and ComponentsAny such action may cause a fire hazard Fire Risk Framing and ClearancesSelect Appliance Location Fire Risk Odor RiskClearances Mantel ProjectionsTermination Locations Vent Termination Minimum ClearancesSecuring and Leveling Appliance Remove Logs and Shipping CoverGas Pressure Gas InformationFuel Conversion Gas Connection Fire Risk Explosion RiskFire Risk Explosion Risk Asphyxiation Risk Valve Access Lift Out DoorsIntellifire Ignition System Wiring Electrical InformationShock Risk Finishing Noncombustible Facing Diagram Facing MaterialGrate Assembly Placement Appliance SetupClean the Appliance Positioning the LogsFront Log SRV727 Glass Assembly Reinstall Door LockPlacing Lava Rock Operating Instructions Before Lighting ApplianceLighting the Appliance Do not connect 110 VAC to the control valveIssue Solutions Frequently Asked QuestionsFire Risk High Temperatures After the Appliance is LitTroubleshooting Symptom Possible Causes Corrective ActionsIntellifire Ignition System Maintaining and Servicing the Appliance Valve Service and Replacement Tools RequiredGround Wire Maintenance and Service Tasks Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsService Parts List DAKOTA42-B, DAKOTA42H-BParts List Service#1BoxSet711Log-4036 This page intentionally left blank This page intentionally left blank Warranty Coverage Warranty This warranty is void ifDDO is N CAO T R D Contact Information
Related manuals
Manual 36 pages 27.89 Kb

42H-B, 42-B specifications

Hearth and Home Technologies has long been a leader in the realm of home heating and comfort solutions, and their 42-B and 42H-B models exemplify this commitment to quality and innovation. These models are designed to meet modern heating needs while providing an aesthetic appeal that enhances any living space.

One of the standout features of the 42-B and 42H-B is their impressive heating capabilities. With a BTU output that can efficiently heat large areas, these units are perfect for homeowners looking to maintain a comfortable environment during the colder months. The ability to generate substantial heat without consuming excessive fuel has made these models a preferred choice among energy-conscious consumers.

In addition to their efficient heating, the 42-B and 42H-B also incorporate advanced venting technologies. These models are designed with flexible venting options, allowing for both direct vent and B-vent installation. This versatility not only simplifies the installation process but also provides homeowners with more options in terms of their heating setup. Whether looking to install in a new build or retrofit an existing space, the 42-B and 42H-B fit seamlessly into various configurations.

Another notable feature of these models is their aesthetic design. Hearth and Home Technologies understands the importance of appearance in maintaining the overall decor of a home. The 42-B and 42H-B come with customizable front options, ensuring that each unit can match the individual style of a home. From traditional to contemporary looks, these models can complement any interior with elegance and charm.

Safety is a top priority for Hearth and Home Technologies, and the 42-B and 42H-B have been designed with several safety features to ensure peace of mind. The units come equipped with a glass front that remains cool to the touch, preventing accidental burns, and advanced safety shutoff mechanisms that activate in the event of a malfunction, ensuring that homeowners can enjoy their heating solutions without worry.

In conclusion, the Hearth and Home Technologies 42-B and 42H-B models combine efficiency, safety, versatility, and style. They offer an exceptional heating experience, making them an attractive option for anyone looking to enhance their home comfort. With their reliable performance and elegant appearance, these units stand as a testament to Hearth and Home Technologies' dedication to quality in the home heating market.