Hearth and Home Technologies 42-B Termination Locations, Vent Termination Minimum Clearances

Page 9

4 Termination Locations

A. Vent Termination Minimum Clearances

 

 

 

 

 

 

O

 

 

 

 

 

 

P

 

 

FP

G

 

R

N

 

 

 

 

FP

 

 

 

 

 

D

 

A

 

H

 

Q

 

 

 

 

 

 

E

 

 

 

 

(See Note 2)

L

B

 

 

 

 

 

FP B

 

 

 

 

 

 

FP

B

 

 

 

 

 

 

 

 

 

 

F FP

FP

 

I

M

X

 

 

 

 

FP

 

 

 

 

 

 

 

 

A

 

 

J or K

 

= FIREPLACE OPENING

X = AIR SUPPLY INLET

 

= AREAWHERE FIREPLACE IS NOT PERMITTED

A= 0 in. . . . . . . . . . clearances above grade, veranda, porch, deck or balcony.

B= 12 in. . . . . . . . . . clearances to window or door that may be opened, or to

 

 

 

permanently closed window.

 

 

36 in

vinyl windows or siding.

D**

=

47 in

vertical clearance to unventi-

 

 

 

lated soffit or to ventilated soffit

 

 

 

located above the terminal.

 

 

60 in

vinyl clad soffits.

F

=

9 in

clearance to outside corner.

G*

=

6 in

clearance to inside corner.

 

 

48 in

vinyl windows or siding.

H= 3 ft. (Canada) . not to be installed above a gas meter/regulator assembly within 3 ft (914 mm) horizontally from the center line of the regulator.

I= 3 ft. (USA)

6 ft. (Canada) . clearance to service regulator vent outlet and electric service.

*48 in. minimum for vinyl windows or vinyl siding.

**Not allowed for vinyl clad soffits.

***a fireplace shall not open directly above a sidewalk or paved driveway which is located between two single family dwellings and services both dwellings.

****only permitted if veranda, porch, deck or balcony is fully open

on a minimum of 2 sides beneath the floor, or if the screened porch guidelines are followed.

Note 1: Local codes or regulations may require different clearances.

Note 2: Termination in an alcove space (spaces open only on one side and with an overhang) are permitted with the dimensions specified for vinyl or non-vinyl siding and soffits. 1) There must be a 3 ft minimum between terminations or between the fireplace and termination. 2) All mechanical air intakes within 10 ft of a termination must be a minimum of 3 ft below the fireplace hood. 3) All gravity air intakes within 3 ft of the fireplace hood must be a minimum of 1 ft below the termination.

Figure 4.1 Minimum Clearances

J

=

9 in. (USA)

 

 

 

12 in. (Canada) . clearance to non-mechanical air

 

 

 

supply inlet to building or the

 

 

 

combustion air inlet to any other

K

=

3 ft. (USA)

appliance.

 

 

 

6 ft. (Canada) . clearance to a mechanical air

 

 

 

supply inlet.

L***

=

54 in. . . . . . . . . . clearance above paved sidewalk

 

(See note 1)

or a paved driveway located on

 

 

 

public property.

M****=

47 in. . . . . . . . . . clearance under veranda, porch,

 

 

 

deck, balcony or overhang.

 

Not allowed: . . . . . . vinyl

N= 6 in. . . . . . . . . . non-vinyl siding. P = 84 in.

 

 

QMIN

RMAX

Dakota

10 feet

2 x Q ACTUAL

1

additional termination cap

Q + 3 feet

1 x Q ACTUAL

2

additional termination caps

Q + 6 feet

2/3 x Q ACTUAL

3

additional termination caps

Q + 9 feet

1/2 x Q ACTUAL

 

RMAX = (2 / # caps plus fireplace ) x QACTUAL

This fireplace is approved for installation onto screen porches with the following guidelines:

Minimum porch area: 96 sq ft

Minimum ceiling height: 84 in.

Minimum of two walls must be screened

Minimum top of screen height, side walls: 6 ft 8 in.

Minimum screen area: 64 sq ft

Note 2: There may be some odor and small amounts of soot associated with burning the Dakota on a screened porch. Ensuring good cross draft ventilation and routine maintenance of the fireplace will maximize comfort and cleanliness.

Outdoor Lifestyles by Hearth & Home Technologies Inc. • Dakota 42-B/Dakota 42H-B4036-909 • Rev L 10/09

Image 9
Contents This appliance must be installed outside What to do if you smell gasHot glass will cause burns Listing Label Information/Location CongratulationsTable of Contents Glass Specifications Appliance Certification BTU SpecificationsHigh Altitude Installations Listing and Code ApprovalsDesign and Installation Considerations Getting StartedMoisture Resistance Tools and Supplies Needed Inspect Appliance and ComponentsAny such action may cause a fire hazard Select Appliance Location Framing and ClearancesFire Risk Fire Risk Odor RiskMantel Projections ClearancesVent Termination Minimum Clearances Termination LocationsRemove Logs and Shipping Cover Securing and Leveling ApplianceFuel Conversion Gas Connection Gas InformationGas Pressure Fire Risk Explosion RiskFire Risk Explosion Risk Asphyxiation Risk Lift Out Doors Valve AccessIntellifire Ignition System Wiring Electrical InformationShock Risk Finishing Facing Material Noncombustible Facing DiagramClean the Appliance Appliance SetupGrate Assembly Placement Positioning the LogsFront Log SRV727 Glass Assembly Reinstall Door LockPlacing Lava Rock Before Lighting Appliance Operating InstructionsDo not connect 110 VAC to the control valve Lighting the ApplianceFire Risk High Temperatures Frequently Asked QuestionsIssue Solutions After the Appliance is LitTroubleshooting Symptom Possible Causes Corrective ActionsIntellifire Ignition System Maintaining and Servicing the Appliance Tools Required Valve Service and ReplacementGround Wire Inspect Maintenance Tasks Maintenance and Service TasksReference Materials Appliance Dimension DiagramDAKOTA42-B, DAKOTA42H-B Service Parts ListService Parts List#1BoxSet711Log-4036 This page intentionally left blank This page intentionally left blank Warranty Coverage This warranty is void if WarrantyContact Information DDO is N CAO T R D
Related manuals
Manual 36 pages 27.89 Kb

42H-B, 42-B specifications

Hearth and Home Technologies has long been a leader in the realm of home heating and comfort solutions, and their 42-B and 42H-B models exemplify this commitment to quality and innovation. These models are designed to meet modern heating needs while providing an aesthetic appeal that enhances any living space.

One of the standout features of the 42-B and 42H-B is their impressive heating capabilities. With a BTU output that can efficiently heat large areas, these units are perfect for homeowners looking to maintain a comfortable environment during the colder months. The ability to generate substantial heat without consuming excessive fuel has made these models a preferred choice among energy-conscious consumers.

In addition to their efficient heating, the 42-B and 42H-B also incorporate advanced venting technologies. These models are designed with flexible venting options, allowing for both direct vent and B-vent installation. This versatility not only simplifies the installation process but also provides homeowners with more options in terms of their heating setup. Whether looking to install in a new build or retrofit an existing space, the 42-B and 42H-B fit seamlessly into various configurations.

Another notable feature of these models is their aesthetic design. Hearth and Home Technologies understands the importance of appearance in maintaining the overall decor of a home. The 42-B and 42H-B come with customizable front options, ensuring that each unit can match the individual style of a home. From traditional to contemporary looks, these models can complement any interior with elegance and charm.

Safety is a top priority for Hearth and Home Technologies, and the 42-B and 42H-B have been designed with several safety features to ensure peace of mind. The units come equipped with a glass front that remains cool to the touch, preventing accidental burns, and advanced safety shutoff mechanisms that activate in the event of a malfunction, ensuring that homeowners can enjoy their heating solutions without worry.

In conclusion, the Hearth and Home Technologies 42-B and 42H-B models combine efficiency, safety, versatility, and style. They offer an exceptional heating experience, making them an attractive option for anyone looking to enhance their home comfort. With their reliable performance and elegant appearance, these units stand as a testament to Hearth and Home Technologies' dedication to quality in the home heating market.