Baxi Potterton 47-393-39, 47-393-40 Short Parts List, 306, 302, Key Description Manufacturers

Page 53

306

426

315316

311

624419

422

400

415

302

421

420

 

503

504

17.0 Short Parts List

Short Parts List

 

Key

G.C.

Description

Manufacturers

 

No.

No.

 

Part No.

 

 

 

 

 

 

 

311

 

Fan

5121447

 

 

 

 

 

 

 

 

426

 

Motor 3 way Valve

5132452

 

 

 

 

 

 

 

 

315

 

Igniter Electrode

720222801

 

 

 

 

 

 

 

 

316

 

Sensing Electrode

720222901

 

 

 

 

 

 

 

 

422

 

Gas Valve

720301001

 

 

 

 

 

 

 

 

404

 

Hall Effect Sensor

5114767

 

 

 

 

 

 

 

 

306

 

Burner 24/28

5122149

 

 

 

 

Burner 33

5114697

 

 

 

 

Burner 40

5114698

 

 

 

 

 

 

 

 

419

 

Water Pressure Switch

5114748

 

 

 

 

 

 

 

 

400

 

Plate Heat Exchanger

5114708

 

 

 

 

 

 

 

 

415

 

Pump

248042

 

 

 

 

 

 

 

 

421

 

NTC Sensor

5114725

 

 

 

 

 

 

 

 

420

 

Overheat Thermostat

5114729

 

 

 

 

 

 

 

 

504

 

Pressure Gauge

248090

 

 

 

 

 

 

 

 

503

 

PCB 24

5121862

 

 

 

 

PCB 28

720043401

 

 

 

 

PCB 33

720795201

 

 

 

 

PCB 40

5122287

 

 

 

 

 

 

 

© Baxi Heating UK Ltd 2012

53

Image 53
Contents Installation & Service Instructions Potterton Titanium Natural GasScheme Members only Installer Notification GuidelinesCodes of Practice refer to the most recent version Important Installation, Commissioning, Service & RepairLegislation General Safe Manual HandlingPreparation TechniqueContents Description Contents of PackIntroduction General Layout Domestic Hot Water Mode Light DisplayLayout Expansion Vessel Automatic Air VentDomestic Hot Water Mode Fig Central Heating Mode FigFrost Protection Mode Appliance OperationTitanium 24, 28, 33 Technical DataOrientation Dimensions and FixingsTap Rail 32.5 mm Condensate Drain 65 mm 22mm 15mmInformation System DetailsCentral Heating Circuit BypassPressure Relief Valve Fig System Filling and Pressurising FigExpansion Vessel Central Heating only Hard Water Areas Domestic Hot Water Circuit FigShowers At Least 1.5 7.2 Clearances Figs Site RequirementsLocation Ventilation of Compartments Site RequirementGas Supply Electrical SupplyCondensate Drain 500mm min 50mm perMinimum fall RunBoiler External runs & those InsulationFlue Flue Options Each fitting to aid assemblyHorizontal Flue Systems Horizontal FluesTwin & Vertical Flue Systems Vertical Flues120mm Min ApartTelescopic Internal Flue Kit Flue AccessoriesKey Accessory Size Code No Air Duct Connection Flue Duct Connection Boiler Adaptor Twin Flue Duct AdaptorTwin Flue Connection For Roof Terminals Flue DimensionsFlue Trim Terminal Guard FigPlume Displacement Kit Fig Plume DisplacementElbow/Plume Outlet Assembly Ring BracketDetermining Permissible Lengths 28/33/40Example Example Flue Lengths OK30mm General Fitting Notes60Ø extension piece. It must be secured using two Elbow to allow the flue to be installed as shownUsing a suitable bit e.g mm, drill through Extension and outlet. Secure using two of the screwsUnpacking & Initial Preparation InstallationFlushing After considering the site requirementsFitting the Filling Loop Kit Condensate Drain see section Fitting The BoilerFitting the Pressure Relief Discharge Pipe Fig Wall Thickness Flue Elbow Fitting The FlueEnsure Elbow is fully engaged into Boiler Adaptor Wall Thickness Waste FlueEnsure Extension is fully engaged into Boiler Adaptor Inner Flue Support Bracket25mm Extension Cut End Preliminary Electrical Checks Making The Electrical ConnectionsCommissioning Selector Switch DisplayCommissioning the Boiler Screw Pump Automatic Air VentPressure Setting the Timer Case Front Panel Facia Panel CompletionCompletion Annual Servicing Inspection Servicing13 .1 Annual Servicing Viewing Window 10 ±1Burner Sensing Electrode Spark and Sensing Electrodes Fig Changing ComponentsIgniter Fig Venturi Fig Fan FigInjector Fig Gasket Venturi Injector Cover Gas Inlet Pipe Fan CollectorBurner Gasket Extension Piece Burner FigInsulation Fig Safety Thermostat Fig Central Heating Temperature Sensor NTC FigDHW Temperature Sensor NTC Fig Flue/Heat Exchanger Thermostat Sensor FigAutomatic Air Vent Fig Pump Head Only FigPump Complete Fig Hall Effect Sensor Fig Pressure Gauge FigsPlate Heat Exchanger Fig Diverter Valve Motor Unit & Assembly Fig14.22 P.C.B. Fig Selector Switch FigExpansion Vessel Fig Throttle Adjustment ScrewGas Valve Fig Setting the Gas Valve CO2 check Setting the Gas ValveFlue Adaptor Test Point Plug Analyser Probe ThrottleElectrical Illustrated Wiring DiagramShort Parts List Short Parts List306 302Error Codes Fault FindingInitial Fault Finding Checks Go to section ‘A’ Turn the selector switch to Error 133 flashingReset position for 5 seconds Pump runsError 133 flashing Go to section ‘I’ Turn selector switch toTurn Domestic Hot Water Open DHW tap fullySwitch terminal PCB X3 connector terminals 3Fan jammed or faulty winding Replace PCB Replace waterReplace sensor or PCB E28 Check wiring Viewing WindowGas at burner Replace gas valveReplace sensor Replace safety thermostatReplace PCB Is there 230V at Page Page GAS Boiler System Commissioning Checklist Service Record Potterton

47-393-40, 47-393-41, 47-393-39, 47-393-42 specifications

The Baxi Potterton 47-393-42, 47-393-39, 47-393-41, and 47-393-40 are models of high-efficiency gas boilers designed for residential heating. These models are well-known for their reliability, advanced technology, and user-friendly features, making them a popular choice among homeowners looking to improve their heating systems.

One of the standout features of these models is their energy efficiency. Each unit is engineered to comply with stringent energy-saving regulations, significantly reducing utility bills while maintaining optimal heating performance. They are rated with impressive efficiency ratings, which can lead to long-term savings and a reduced carbon footprint.

The Baxi Potterton range employs a heat exchanger system designed to maximize heat transfer and minimize energy waste. This sophisticated technology ensures that the boiler operates at peak efficiency, providing ample heating for homes even in the coldest months. The use of a durable, high-quality heat exchanger material contributes to the longevity of the unit, reducing the need for frequent repairs or replacements.

Ease of use is another hallmark of the 47-393 series. With an intuitive digital display, users can effortlessly monitor and adjust settings as required. The controls are straightforward, allowing for quick temperature adjustments, system diagnostics, and alerts, creating a hassle-free experience for homeowners.

Safety features are inherent in these models, including built-in safeguards against overheating and pressure fluctuations. The automatic shut-off mechanism ensures that the boiler operates within safe parameters, providing peace of mind to users.

Furthermore, maintenance is simplified with the easy access design. The accessible components make it straightforward for service technicians to perform routine checks and repairs. Regular maintenance is essential for sustaining high performance and extending the lifespan of the boiler.

In conclusion, the Baxi Potterton 47-393-42, 47-393-39, 47-393-41, and 47-393-40 models represent a blend of efficiency, safety, and convenience. Their advanced technologies and features not only enhance the user experience but also contribute to more sustainable heating solutions for homes. Investing in one of these advanced boilers ensures reliable performance, lower energy costs, and a commitment to environmental responsibility.