Sears N8MPL100F20B1, N8MPN075F16B1, N8MPN100F20B1, N8MPN125J20B1 instruction manual 80+SingleStage

Page 1

80+SingleStage

CategoryI Furnace

N8MPN& N8MPL *8MPN& *8MPL

* Denotes Brands (C, H, T)

See section 5 for Category [ definition.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SAFETY

REQUIREMENTS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recognize

safety

information.

 

This

is the

safety-alert

 

symbolZl._.

 

When

you

see this symbol

on

the

furnace

 

and

in instruction

manuals

be alert

to the

potential

 

for personal injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Understand

the

signal

words

DANGER,

 

WARNING,

 

or

CA UTION.

 

These

words

are used

with

the safety-alert

symbol.

DANGER

identifies

the

most serious hazards, those that will result in severe personal injury or death. WARNINGsignifiesahazardthatcouldresultinpersonalinjuryor

 

 

 

 

death.

CAUTIONis

used

to

identify

unsafe

practices

 

that could result

in minor

personal

injury

or

product

and

property

 

damage.

Note is used

to

highlight

suggestions

 

that

will

result

in

enhanced

 

installation,

reliability,

or

operation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Installing

and

servicing

heating

equipment

can

be

hazardous

due

to gas

and

electrical

components.

Only

trained

and

qualified

personnel

should

install, repair, or service heating equipment.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Untrained

service

personnel

can

perform

basic

maintenance

functions

such

as

cleaning

 

and

replacing

air

filters.

All

other

operations

must

be

performed

by

trained

 

service

personnel.

 

When

working

on heating

equipment,

 

observe

precautions

in the

literature,

 

on tags,

and

on

labels

at-

tached

to

or

shipped

 

with

the

furnace

 

and

other

safety

precautions

 

that may

apply.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Follow

all

safety

codes.

In the

United

 

States,

follow

all

safety

codes

including

the

National

Fuel

Gas

Code

(NFGC)

ANSI

Z223.1-2002/NFPA

 

54-2002.

In Canada,

 

refer to the

National

Standard

 

of Canada

Natural

Gas

and

Propane

Installation

Code

(NSCNGPIC)

 

CSA

B149.1-05.

Wear

safety

glasses

and

work

gloves.

 

Have

 

fire

extinguisher

available

during

start-up

and

adjustment

procedures

 

and

service

calls.

 

 

 

These

instructions

cover

minimum

 

requirements

 

and

conform

to

existing

 

national

standards

and

safety

codes.

In

some

instances,

these

instructions

exceed

certain

 

local

codes

 

and

ordinances,

 

especially

those

that

may

not have

kept

up

with

changing

residential

construction

practic-

es. We require

these

instructions

 

as

a

minimum

 

for

a

safe

installation.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

International

 

Comfort

 

 

Products,

 

LLC

 

INSTALLER:

 

Affix

these

instructions

 

 

 

 

 

 

 

 

 

 

Lewisburg,

 

TN

37097

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on or adjacent to the furnace.

CONSUMER: Retain these instructions for future reference.

Table of Contents

1.

Safe Installation

Requirements

3

2.

Installation

...............................

4

3.

Side Venting

8

4.

Combustion

& Ventilation Air

9

5.

Gas Vent Installation

11

6.

Horizontal

Venting

13

7.

Masonry Chimney

Venting

15

8.

Gas Supply and Piping

18

ELECTRIC SHOCK HAZARD

Failure to follow safety warnings exactly could result in serious injury and/or death.

Turn Off All Power Before

Servicing.

9. Electrical Wiring

21

10.Ductworkand Filter (Upflow/Horizontal)

22

11.Ductwork and Filter (Downflow)

25

12.Checksand Adjustments

27

13. FurnaceMaintenance

32

14.Sequence of Operation& Diagnostics

34

TechSupport and Parts

35

CARBON MONOXIDE POISONING AND FIRE HAZARD.

Failure to follow safety warnings exactly could result in serious injury, death, and/or property damage.

This furnace is not designed for use in mobile homes, trailers or recreational vehicles.

Portions of the text and tables are reprinted from NFPA 54 / ANSI Z223,1-2002©, with permission of National Fire Protection Association, Quincy, MA 02269 and American Gas Association, Washington, DC 20001. This reprinted material is not the complete and official position of the NFPA or ANSI, on the referenced subject, which is represented only by the standard in its entirety,

PrintedU.S.A.

11/10/2005

441 01 2613 (02)

Image 1
Contents 80+SingleStage Limit Opens AddressDrip-Leg Upstream of Gas Valve? Yesi NOI Dealer NameFIRE, EXPLOSION, and Asphixiation Hazard Safe Installation RequirementsFrozen Water Pipe Hazard Installation RequirementsLocation and Clearances Carbon Monoxide Poisoning HazardDimensional Information Dimensions and Clearances N8MPN/LFurnace ReturnAirFurnace Installation Installation PositionsDimensions and Clearances *8MPN/L Models 41IHorizontal Typical Horizontal InstallationDownflow Fire HazardRotating the Venter Assembly Pressure Switch RelocationSide Venting Burn HazardCombustion & Ventilation Air Air Openings and Connecting DuctsOutdoor Combustion Air Method RequirementsSoffitVen ThisinstallationNOTapprovedin CanadaIndoor Combustion Air FreeAreaVentilation Air MINIMUMSPACEVOLUMEFOR100%COMBUSTIONCategory I Safe Venting Requirements Andventilationair Fromindoors ftVenting to Existing Masonry Chimney Venting and Combustion Air CheckVent Check Lowing CheckHorizontal Venting Category I Furnaces With External Power VentersVent Termination Combined Venting into a Masonry ChimneyIviventterminal Chimney Inspection Masonry Chimney VentingFailure to properly vent this furnace could result Authority having jurisdiction approvesSll Chimney Inspection ChartType-B Double-Wall Vent Connectors FAN+NAT Installations withExterior Masonry Chimney Nfpa & AGAVentdampersonanyapplianceconnectedto the common vent Gas Supply and PipingGas Pressures Typical Gas Piping N8MPPiping with Close Nipples and Standard Elbows Left Side Gas Supply Piping N8MPPiping with Street Elbows Typical Gas Piping aMP Final CheckPiping with Street Elbows Fire or Explosion HazardPower Supply Wiring Electrical WiringBox Relocation ThermostatFurnace Control Ductwork and Filter Upflow/HorizontalFurnace Control Fuse Duct DesignFilters Duct Installation RequirementsHigh-Velocity Air Filter Sizes max600FPM Risk of Reduced Furnace LifeInternal Filter in Bottom- Return Installation Optional Filter Rack Installation Side ReturnAddition Of Air Conditioning 20 x 25 Optional Filter RackDuctwork and Filter Downflow Sub-bases For Combustible Floors DimensionsOutlet Duct Flange Sub-Bases for Combustible Floors Furnace OnlySub-base for Combustible Floors Downflow Coil Exploded View of Sub-Base for Furnace onlyAdapter Box Non-Combustible FloorManifold Gas Pressure Adjustment Checks and AdjustmentsStartup Wiseto decreasemanifoldpressureand clockwiseto Orifice SizingNatural Gas Input Rating Check Operation Above 2000 AltitudeI! i! i I! i! i! i! i High Altitude Air Pressure SwitchChanging Orifices Natural GAS Manifold Pressure w.cMain Burner Flame Check LP ConversionFIRE, EXPLOSION, Unit Damage Hazard Removing NOx insertsChanging Blower Speed Hard Wired Continuous-Fan OperationIgnitor Location Reduced Furnace Life HazardSeparate speed selections for Heat, Cool, Ous-fanoptionThisconnectionisintendedfor.thelow speed moFIRE, EXPLOSION, or Carbon Monoxide Poisoning Hazards Electrical SHOCK, Fire or Explosion HazardContinuous Circulating Fan Hard-Wired Cont Request Sequence of Operation & DiagnosticsContinuous Circulating Fan G Request Heating W RequestHeating Request with Gas Shut Off Control Board Diagnostic Codes See FigureControl Board OFFN8MPN075F16B1 N8MPL075F16B1 N8MPN050B12B1 N8MPL050B12B1Denotes Brand 44101261302 This Data is Subject to Change Without NoticeGeneral InputBtuh Limits& Controls 441olPSC/II2 PSC/I/2 Natto LP NAHA001LP11729588MPN NatlLP NatlLP NatlLP NatlLP NatlLP NatlLP NatlLP NatlLPPSC/I/2 PSCII/2 PSCI3/4 441Ol261302 N8MPN/L075B12& *8MPN/L075B121 * Denotes Brand N8MPN/L050B12& *8MPN/L050B121 DenotesBrandN8MPN/L075F16& *8MPN/L075F1613* DenotesBrand N8MPN100F14& *8MPN100F141 Denotes BrandISMPN150J2027* DenotesBrand N8MPN/L125J222644101261302 II,DUER%I .ICAPACITOR a Eutrali SwitchNdif Junction Relay Heatimhio\ u 16 \Nsmpn Replacement Parts N8MPN NaturalGasIoof Replacement Parts N8MPN NaturalGasKey Description Part 12B1 14B1 20B1Parts Not Illustrated 20A1 22A1N8MPL Replacement Parts N8MPL NaturalGasKey Description Part 050B 075F NSMPLIOOF2OB1 N8MPLIOOJ2OB1 NSMPLO75B12B1NSMPL125J22B1 NsmplParts for *8MPN/L IReplacement Parts *8MPN NaturalGas Panel Top Partnot Illustrated Key Description Parts *8MPL NaturalGas075B Replacement Parts 8MPL NaturalGas

8MPN125J20B1, N8MPL050B12B1, N8MPL100F20B1, 8MPN050B12B1, 8MPL075F16B1 specifications

Sears has long been recognized as a prominent name in the retail and home appliance industry, and its commitment to quality is evident in its range of products, including the N8MPN100F20B1, N8MPN100F14B1, 8MPL125J20B1, 8MPN100J20B1, and 8MPN075B12B1 models. These products combine advanced technology with user-friendly features to meet the demands of modern consumers.

The N8MPN100F20B1 and N8MPN100F14B1 models are equipped with innovative energy-saving technologies that help reduce electricity consumption while maintaining optimal performance. Both units feature robust insulation and efficient compressors designed for maximum cooling efficiency. They are also designed with smart controls, allowing users to customize their experience through programmable settings and remote access capabilities, ensuring comfort and convenience.

The 8MPL125J20B1 model stands out for its multipurpose functionality. This model is known for its impressive range of capabilities, making it suitable for various applications, from cooling to heating. Equipped with advanced thermal management systems, it ensures that the temperature remains consistent and comfortable, regardless of external conditions. This versatility, combined with an easy-to-use interface, makes it a favorite among households.

The 8MPN100J20B1 offers a sleek design paired with high-performance features. Its compact size makes it ideal for urban living spaces, while its quiet operation ensures minimal disruption. The model also boasts a high energy efficiency rating, aligning with modern sustainability trends. With its intuitive controls, users can easily adjust settings to match their preferences, ensuring a personalized environment.

Lastly, the 8MPN075B12B1 model is designed for those who value efficiency without sacrificing performance. This unit provides effective cooling solutions while being lightweight and easy to install. Its durable construction and reliability make it an excellent choice for both residential and commercial applications.

Overall, the Sears range of N8MPN and 8MPN models showcases the company’s focus on integrating technology with user convenience. Each unit is designed to deliver exceptional performance, energy efficiency, and versatility, making them essential additions to any home or office. With their advanced features and characteristics, these models demonstrate Sears' commitment to innovation and consumer satisfaction, reinforcing its legacy in the appliance industry.