GE RAK148P1, RAK164P1 Adjust to control the minimum Cool set temperature allowed

Page 9

3.Temperature Differential—Stage 2—(RAK148P1 only) (1–9°F) (1–5°C)—Set the number of degrees between when stage 1 turns on and stage 2 turns on.

Press the

<

or

>

button to set differential value.

Press the Hold button to advance to the next screen.

4. Minimum Cool Setpoint (60, 64, 66, 68, 70, 72, 74, 76°F) (15, 17, 19, 20, 21, 22, 23, 24°C)

Adjust to control the minimum Cool set temperature allowed.

Press the

<

or

>

button to select.

Press the Hold button to advance to the next screen.

5. Maximum Heat Setpoint (65, 70, 72, 74, 76, 78, 80, 85°F) (18, 21, 22, 23, 24, 26, 27, 29°C)

Adjust to control the maximum Heat set temperature allowed.

Press the

<

or

>

button to select.

Press the Hold button to advance to the next screen.

6. Room temperature offset (+9°F to –9°F) (+5°C to –5°C)

Adjust to calibrate displayed room

temperature to match actual room temperature.

Press the

<

or

>

button to select.

Press the Hold button to advance to the next screen.

Move the Function switch to Heat or Cool position to lock the settings into memory.

9

Image 9
Contents Thermostats Installation InstructionsSpecifications Important safety informationIntroduction Overview Thermostat Control Installation Instructions Use supplied screws to mount thermostat base to wall Turn off power to the heating and cooling systemWiring diagrams Terminals for six wires 2 heat/1 cool system RAK148P1 only Configuration Mode Settings Configuration modeSetup screens for Configuration Mode are as follows Each screenAdjust to control the maximum Heat set temperature allowed Adjust to control the minimum Cool set temperature allowedOperation Setting the Room Temperature Setpoint TemperatureTesting the thermostat Starting the thermostatAir conditioning should come on within a few seconds Heat Test Heat should come on within a few secondsFan Test Off Operating functionsCool HeatSetting the time and day of the week Programming Program OverviewOff position Heat temperature is displayed 60F to 85F Repeat ProgrammingPress the button and hold for Seconds. The days of the week Factory preprogramming Low battery warning, Off mode Low battery indicatorLow battery warning, Cool mode Low battery warning, Heat modeCombination failure, Off mode Combination failure, Cool modeCombination failure, Heat mode Problem Solution Troubleshooting tipsPage Page Page For The Period GE Will Replace Thermostat Warranty