AMX ENV-VST-C manual AxLink Commands

Page 59

Programming

5-Day Forecast Commands (Cont.)

FL Forecasted 5-day low temperature

Syntax:

FL <LT1> <LT2> <LT3> <LT4> <LT5>

Variable:

LTx = The low temperature in degrees expected for day x, where x = 1 is the current day, 2 is the next day, etc. Example:

SEND_COMMAND ’FL 37 39 40 41 38’

Five-day low temperatures.

FK Forecasted 5-day weather conditions. The current weather condition (KYC) is optional.

Syntax:

FK <KY1> <KY2> <KY3> <KY4> <KY5> <KYC>

Variable:

KYx = The weather condition expected for day x, where x = C is the current weather condition, x = 1 is the current day’s forecast, 2 is the next day’s forecast, etc.

Example:

SEND_COMMAND ’FK SNOW ICE SNOWSW SNOWFL SLEET’

Five-day weather condition forecast.

SEND_COMMAND ’FK SNOW ICE SNOWSW SNOWFL SLEET SNOWFL’

Five-day weather condition forecast with the current weather condition.

AxLink Commands

This section contains AxLink commands that are specific to the ViewStat Color Thermostat. For additional AxLink programming commands specific to a particular AxLink device, consult the manual for the AxLink device you are using.

AxLink Commands

BK

CD

Sets the backlight timeout value and active and inactive brightness.

Syntax:

BK [T<SEC>] [A<ABVAL>] [I<IBVAL>]

Variables:

SEC = An integer with a value between 10 and 300 in values evenly divisible by 10.

ABVAL = A single character with a value of L, M, or H, where L=Low, M=Medium, and H=High IBVAL = A single character with a value of D or O, where D=Dim and O=Off

Example:

SEND_COMMAND ’BK T20 IO’

Sets the timeout to 20 seconds and Inactive Brightness to OFF.

SEND_COMMAND ’BK T10 AL’

Sets the timeout to 10 seconds and Active Brightness to ON.

Retrieves and sets the security code configuration.

Syntax:

CD <Code>

Variable:

Code = A 4-character integer.

Example:

SEND_COMMAND ’CD 1988’

Changes the security code to 1988.

ENV-VST-C - Operation / Reference Guide

53

 

 

Image 59
Contents ENV-VST-C AMX Limited Warranty and Disclaimer Table of Contents Advanced Thermostat Operations Programming AxLink Channels AxLink Levels Weather Duet Module System Components ViewStat Color Thermostat SpecificationsOverview Communication and Hvac ENV-VST-TSO Outdoor Temperature Sensor SpecificationsStand-Alone Thermostat Mounting Criteria Disconnecting Power to All Hvac EquipmentRemote Temperature Sensors Selecting the Thermostat LocationMounting the Base to a Wall Wiring the ThermostatRemoving the Faceplate from the Base Communication and Equipment Terminal Wiring Definitions Wiring TerminalsCommunication and Equipment Terminal Wiring Definitions Wiring for AxLink Preparing Captive WiresWiring Guidelines Single Stage Furnace and Single Stage A/C Wiring DiagramsDual Stage Furnace and Dual Stage A/C Dual Stage Furnace and Dual Stage A/C wiringRoof Top Unit with Dual Stage Heat and Dual Stage Cool Boiler and A/C with Separate Transformers Boiler and A/C with Separate Transformers wiringSingle Stage Heat Pump Single Stage Heat Pump wiringTwo Stage Heat Pump Two Stage Heat Pump wiringInstallation and Wiring Installing the Outdoor Temperature Sensor Installing a Remote SensorIndoor Flush Mount Temperature Sensor Specifications Installing the Indoor Flush Mount SensorSensor wire connected to cable Navigating the ViewStat Color Communicating Thermostat Front Panel ComponentsMain Screen Status Icons Changing the Heating and Cooling SetpointsTo Program Changing Hold ModeChanging the Heating/Cooling Mode Hold Mode OptionsStops blinking Changing the Fan ModeHeating/Cooling Mode Options Turning Off the Hvac SystemOr cooling Fan Mode OptionsHelp Screen Fan AutoDay Forecast Screen Current Weather ScreenExit Returns to the Main screen Thermostat Mode ScreenThermostat Mode Screen Options Program Screen Options Establishing Daytime/Nighttime Temperature SettingsProgram Screen Copy To screen Copying Programmed SettingsAway Mode Screen Options Away Mode ScreenEstablishing Away Mode Settings Settings Screen Options Settings ScreenChanging the Fan Settings Changing the Filter Settings Security Code Screen Accessing Advanced Setup OptionsChanging User Preferences Change Security Code Screen Entering the Security CodeChanging the Security Code User Preferences Screen Options User Preferences ScreenChanging the Date and Time Format Changing the Temperature ScaleDisabling the Filter Change Reminder Changing the Backlight SettingsDisabling the Screen Saver Disabling the Weather Alert IconDisabling the Forecast Screens Button Lockout Screen Options Button Lockout ScreenLocking the Buttons Locking the Temperature SettingsLocking the Mode Settings Locking the Fan SettingsAdvanced Setup Screen Options Advanced Setup ScreenChanging the Type of Hvac System When Diagnostic Mode is activeActivating the External Sensor Changing the Type of Fossil FuelActivating the On-board Humidity Sensor Setting the Date and Time on the ThermostatActivating the Internal On-board Sensor Advanced Setup screen 2 Turning on Diagnostic ModeTurning on the Humidification and Dehumidification Systems Turning on Comfort RecoveryAxLink Communications screen AxLink Communications ScreenSwitching AxLink Devices Thermostat Setup Screen Options Thermostat SetupThermostat Setup Screen Setting the Deadband Temperature Difference Setting First and Second Stage DifferentialsSetting the Balance Point for a Heat Pump System Setting the Temperature OffsetThermostat Setup screen 2 SENDCOMMANDs SENDCOMMANDsWeather Condition Keywords Color ViewStat Thermostat CommandsDay Forecast Commands Day Forecast CommandsAxLink Commands AxLink CommandsTo Off, the response reports OFF Temperature scaleDisplays the current forecast Dew Point 55FSendcommand ’LK MR1 TR3’ Sets the mode to Program Thermostat returns the serial number Sets the current barometric pressureRequest the thermostat’s serial number Master requesting the thermostat’s serial numberAxLink Channels AxLink Channels2nd stage heat relay Provides feedback from relay W2 246 219Hvac State Emergency Heat 224AxLink Levels AxLink LevelsWeather Duet Module InConcert window Weather Setup PagesWeather Main Changing the Date and TimeChanging the Humidity Mode Changing the Humidity SettingsHumidity menu Changing the Heat and Cool SettingsHvac Mode menu Changing the Hvac ModeEntering Location by Zip Code Changing the Hold ModeChanging Pressure Units Changing Temperature UnitsEntering Location by Station ID Changing Wind Speed UnitsDay Forecast screen Programming ENV-VST-C Operation / Reference Guide Increase Your Revenue through education + knowledge
Related manuals
Manual 2 pages 4.04 Kb

ENV-VST-C specifications

The AMX ENV-VST-C is an advanced video streaming and encoding solution designed to meet the needs of modern broadcasting and professional video applications. Known for its high-performance capabilities and seamless integration into existing systems, the ENV-VST-C stands as a reliable choice for content creators, broadcasters, and businesses alike.

One of the main features of the AMX ENV-VST-C is its ability to support a wide range of video formats and resolutions. The device is capable of encoding and streaming in 4K, Full HD, and SD resolutions, ensuring that users can produce high-quality content regardless of their specific requirements. This versatility makes it suitable for various applications, including live event streaming, corporate communications, and even online educational platforms.

The ENV-VST-C utilizes state-of-the-art encoding technologies, such as H.264 and H.265, providing users with high-quality video while optimizing bandwidth usage. H.265, in particular, allows for significantly smaller file sizes compared to H.264, all without sacrificing video quality. This efficiency is crucial for users looking to reduce costs associated with bandwidth and storage, especially in environments where video distribution is critical.

Another key characteristic of this encoder is its user-friendly interface. The AMX ENV-VST-C features an intuitive control panel and web interface that allows users to configure settings, monitor performance, and manage live streams effortlessly. This ease of use is essential for operators who may not have in-depth technical knowledge but need to manage complex streaming tasks efficiently.

In addition, the AMX ENV-VST-C supports multiple streaming protocols, including RTMP, RTSP, and MPEG-TS. This capability enables seamless integration with various content delivery networks (CDNs) and ensures that users can reach their audience effectively across different platforms.

Moreover, the device is designed with reliability in mind. It offers features such as redundant power supplies and advanced cooling systems, which help maintain optimal performance even in demanding environments. This reliability is crucial for live streaming applications, where any downtime can result in significant loss of engagement and revenue.

In conclusion, the AMX ENV-VST-C stands out with its robust feature set, cutting-edge technologies, and user-centric design. Whether you are in broadcasting, corporate communication, or education, this encoder provides the performance and flexibility needed to deliver exceptional video content. With its commitment to quality and efficiency, the AMX ENV-VST-C is a valuable asset for anyone looking to enhance their video production capabilities.