AMX ENV-VST-C manual Sendcommand ’LK MR1 TR3’

Page 61

Programming

AxLink Commands (Cont.)

LK

Configures button lockout settings for temperature, mode, and fan speed

You can completely block anyone from using the buttons on the front of the unit to change the hold temperature, mode, or fan speed changes, or restrict them by time. You can also restrict hold temperature changes by range.

If you configure a time limit, the hold temperature, mode, or fan speed reverts to the original settings after the set time expires.

If you configure a range, the hold temperature may not be set higher or lower than the set temperature +/- the range.

Syntax:

LK [MR<State>] [MT<Time>] [FR<State>] [FT<Time>] [TR<State>] [TT<Time>] [RR<Range>]

Variables:

State = An integer value, 0 for disable and 1 for enable.

Time = An integer representing the number of minutes a change is enabled.

Range = An integer representing the number of degrees a temperature is allowed to be changed. Degrees are in the same scale as set on the thermostat.

MR = Mode Restriction, State=1: disable all changes to Mode. State=0: restrictions to Mode determined by MT (Mode Time Restriction).

MT = Time Restriction placed on changes to TSTAT Mode

FR = Fan Speed Restriction, State=1: disable all changes to Fan Speed. State=0: restrictions to Fan Speed determined by FT (Fan Speed Time Restriction).

FT = Time Restriction placed on changes to Fan Speed

TR = Temperature Restriction, State=1: disable all changes to Temperature Heat and Cool Setpoints.

State=0: restrictions to Temperature Heat and Cool Setpoints determined by TT (Temperature Time Restriction), and TR (Temperature Range Restriction).

TT= Time Restriction placed on changes to Temperature RR = Range Restriction placed on changes to Temperature

Examples:

SEND_COMMAND ’LK MR1 TR3’

Configures the lockout to completely block changes to Mode and restrict changes to the temperature setting to ±3 degrees.

SEND_COMMAND ’LK TT90 FT90’

Configures the lockout to allow changes to the temperature and fan speed for 90 minutes before reverting to the original settings.

ENV-VST-C - Operation / Reference Guide

55

 

 

Image 61
Contents ENV-VST-C AMX Limited Warranty and Disclaimer Table of Contents Advanced Thermostat Operations Programming AxLink Channels AxLink Levels Weather Duet Module Overview ViewStat Color Thermostat SpecificationsSystem Components Communication and Hvac ENV-VST-TSO Outdoor Temperature Sensor SpecificationsRemote Temperature Sensors Disconnecting Power to All Hvac EquipmentSelecting the Thermostat Location Stand-Alone Thermostat Mounting CriteriaRemoving the Faceplate from the Base Wiring the ThermostatMounting the Base to a Wall Communication and Equipment Terminal Wiring Definitions Wiring TerminalsCommunication and Equipment Terminal Wiring Definitions Wiring Guidelines Preparing Captive WiresWiring for AxLink Single Stage Furnace and Single Stage A/C Wiring DiagramsDual Stage Furnace and Dual Stage A/C Dual Stage Furnace and Dual Stage A/C wiringRoof Top Unit with Dual Stage Heat and Dual Stage Cool Boiler and A/C with Separate Transformers Boiler and A/C with Separate Transformers wiringSingle Stage Heat Pump Single Stage Heat Pump wiringTwo Stage Heat Pump Two Stage Heat Pump wiringInstallation and Wiring Installing the Outdoor Temperature Sensor Installing a Remote SensorIndoor Flush Mount Temperature Sensor Specifications Installing the Indoor Flush Mount SensorSensor wire connected to cable Navigating the ViewStat Color Communicating Thermostat Front Panel ComponentsMain Screen Status Icons Changing the Heating and Cooling SetpointsChanging the Heating/Cooling Mode Changing Hold ModeHold Mode Options To ProgramHeating/Cooling Mode Options Changing the Fan ModeTurning Off the Hvac System Stops blinkingHelp Screen Fan Mode OptionsFan Auto Or coolingDay Forecast Screen Current Weather ScreenThermostat Mode Screen Options Thermostat Mode ScreenExit Returns to the Main screen Program Screen Establishing Daytime/Nighttime Temperature SettingsProgram Screen Options Copy To screen Copying Programmed SettingsEstablishing Away Mode Settings Away Mode ScreenAway Mode Screen Options Changing the Fan Settings Settings ScreenSettings Screen Options Changing the Filter Settings Changing User Preferences Accessing Advanced Setup OptionsSecurity Code Screen Change Security Code Screen Entering the Security CodeChanging the Security Code User Preferences Screen Options User Preferences ScreenChanging the Date and Time Format Changing the Temperature ScaleDisabling the Filter Change Reminder Changing the Backlight SettingsDisabling the Forecast Screens Disabling the Weather Alert IconDisabling the Screen Saver Button Lockout Screen Options Button Lockout ScreenLocking the Buttons Locking the Temperature SettingsLocking the Mode Settings Locking the Fan SettingsAdvanced Setup Screen Options Advanced Setup ScreenChanging the Type of Hvac System When Diagnostic Mode is activeActivating the External Sensor Changing the Type of Fossil FuelActivating the Internal On-board Sensor Setting the Date and Time on the ThermostatActivating the On-board Humidity Sensor Advanced Setup screen 2 Turning on Diagnostic ModeTurning on the Humidification and Dehumidification Systems Turning on Comfort RecoveryAxLink Communications screen AxLink Communications ScreenSwitching AxLink Devices Thermostat Setup Screen Thermostat SetupThermostat Setup Screen Options Setting the Deadband Temperature Difference Setting First and Second Stage DifferentialsSetting the Balance Point for a Heat Pump System Setting the Temperature OffsetThermostat Setup screen 2 SENDCOMMANDs SENDCOMMANDsDay Forecast Commands Color ViewStat Thermostat CommandsDay Forecast Commands Weather Condition KeywordsAxLink Commands AxLink CommandsDisplays the current forecast Temperature scaleDew Point 55F To Off, the response reports OFFSendcommand ’LK MR1 TR3’ Sets the mode to Program Request the thermostat’s serial number Sets the current barometric pressureMaster requesting the thermostat’s serial number Thermostat returns the serial numberAxLink Channels AxLink ChannelsHvac State Emergency 219Heat 224 2nd stage heat relay Provides feedback from relay W2 246Weather Duet Module AxLink LevelsAxLink Levels InConcert window Weather Setup PagesWeather Main Changing the Date and TimeChanging the Humidity Mode Changing the Humidity SettingsHumidity menu Changing the Heat and Cool SettingsHvac Mode menu Changing the Hvac ModeEntering Location by Zip Code Changing the Hold ModeEntering Location by Station ID Changing Temperature UnitsChanging Wind Speed Units Changing Pressure UnitsDay Forecast screen Programming ENV-VST-C Operation / Reference Guide Increase Your Revenue through education + knowledge
Related manuals
Manual 2 pages 4.04 Kb

ENV-VST-C specifications

The AMX ENV-VST-C is an advanced video streaming and encoding solution designed to meet the needs of modern broadcasting and professional video applications. Known for its high-performance capabilities and seamless integration into existing systems, the ENV-VST-C stands as a reliable choice for content creators, broadcasters, and businesses alike.

One of the main features of the AMX ENV-VST-C is its ability to support a wide range of video formats and resolutions. The device is capable of encoding and streaming in 4K, Full HD, and SD resolutions, ensuring that users can produce high-quality content regardless of their specific requirements. This versatility makes it suitable for various applications, including live event streaming, corporate communications, and even online educational platforms.

The ENV-VST-C utilizes state-of-the-art encoding technologies, such as H.264 and H.265, providing users with high-quality video while optimizing bandwidth usage. H.265, in particular, allows for significantly smaller file sizes compared to H.264, all without sacrificing video quality. This efficiency is crucial for users looking to reduce costs associated with bandwidth and storage, especially in environments where video distribution is critical.

Another key characteristic of this encoder is its user-friendly interface. The AMX ENV-VST-C features an intuitive control panel and web interface that allows users to configure settings, monitor performance, and manage live streams effortlessly. This ease of use is essential for operators who may not have in-depth technical knowledge but need to manage complex streaming tasks efficiently.

In addition, the AMX ENV-VST-C supports multiple streaming protocols, including RTMP, RTSP, and MPEG-TS. This capability enables seamless integration with various content delivery networks (CDNs) and ensures that users can reach their audience effectively across different platforms.

Moreover, the device is designed with reliability in mind. It offers features such as redundant power supplies and advanced cooling systems, which help maintain optimal performance even in demanding environments. This reliability is crucial for live streaming applications, where any downtime can result in significant loss of engagement and revenue.

In conclusion, the AMX ENV-VST-C stands out with its robust feature set, cutting-edge technologies, and user-centric design. Whether you are in broadcasting, corporate communication, or education, this encoder provides the performance and flexibility needed to deliver exceptional video content. With its commitment to quality and efficiency, the AMX ENV-VST-C is a valuable asset for anyone looking to enhance their video production capabilities.