To ENABLE and program the relay:

1.

Make sure the thermostat is in the OFF mode.

2.

Press and hold the

and

buttons for 3 seconds. The

To DISABLE the relay:

1.

Make sure the thermostat is in the OFF mode.

2.

Press and hold the

and

buttons for 3 seconds. The

(7) OPTIONAL – INSTALL AN APRILAIRE MODEL 8052 OUTDOOR TEMPERATURE SENSOR

 

display will show the ADV. SETTINGS MENU.

3.

Scroll down through the menu items and select

 

PROGRAMMABLE OUTPUT.

4.

Select ENABLE. The display will then show the program

 

event names, and whether the output is to be ON or OFF

 

during that event.

 

5.

Use the multi-function buttons labeled and to toggle

 

between events and highlight the ON/OFF item to change.

 

Use the

and

buttons to change the highlighted item

 

to ON or OFF.

 

6.

Repeatedly press

until DONE is highlighted, where the

 

multi-function buttons are labeled CANCEL and SAVE. Press

 

SAVE to save the values set, or press CANCEL to return to

 

the PROGRAMMABLE OUTPUT menu.

 

display will show the ADV. SETTINGS MENU.

3.

Scroll down through the menu items and select

 

PROGRAMMABLE OUTPUT.

4.

Select DISABLE. The display will then return to the ADV.

 

SETTINGS MENU.

Note: If an ADHC is to be installed, do not wire an outdoor temperature sensor– see Step 8. The ADHC uses its own outdoor temperature sensor, which can be read by the thermostat.

1.Mount the outdoor temperature sensor (see Figure 7).

Locate on the North side of the building if possible. East and West are acceptable locations as long as the sensor will not be exposed to direct sunlight.

Mount above anticipated snow line.

Mount at least 3 feet away from exhaust vents and condensing units.

Maximum wire length from sensor to thermostat is 300 feet.

Under a soffit or under a wall overhang are recommended areas for mounting the sensor.

Figure 7

NORTH, EAST

OR WEST SIDE

OF BUILDING

SENSOR WITH

BRACKET

ABOVE SNOW LINE

- 18 -

- 19 -

Image 12
Contents Safety & Installation Instructions Table of Contents Safety Instructions Model 8570 SpecificationsWire Requirements Open the Thermostat Mount the Thermostat Base to the WallSet to HP when installed with heat pumps Single Multi Elect GASWire the Thermostat to the Hvac Equipment Run a cable with the correct number of wiresAprilaire Model Diagram 4 Boiler with AC Diagram 7 Single-Stage Heat Pump with Two-Stage Optional Wire the Event Triggered Output ETO Turn it off when unoccupiedLoad Settings Menu Programmable OutputNORTH, East Or West Side230.6 163.8117.6 85.4Mount the Adhc and its outdoor temperature sensor ThermostatMount the indoor temperature sensor Control SET UP Thermostat SET UP SET Number of Auxiliary Heat StagesAuxiliary Heat Setup Thermostat Startup Stand Alone ApplicationsCheck FAN Operation Check Heating Operation Check Cooling Operation Thermostat does not call for coolingTo Cool and make a call for cooling MultiTo Emergency Heat and make a call for heat Single/Multi Same outputs come onRegardless of how these are set GasCustomize the Application Settings Offset ADV. Settings Menu Range is -10F to 35F and OFFTo go back a character, press the Back button Press the Call Dealer button Press the Reset button Press the Menu buttonBOX 1467 MADISON,WI