Aprilaire 8570 installation instructions Table of Contents

Page 2

TABLE OF CONTENTS

PAGE

SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 WIRE REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . 2 1. SELECT A MOUNTING LOCATION. . . . . . . . . . . 3

2. OPEN THE THERMOSTAT . . . . . . . . . . . . . . . . . . 4

3. MOUNT THE THERMOSTAT BASE

TO THE WALL . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

4. SET THE CONFIGURATION DIP SWITCHES ON THE THERMOSTAT CIRCUIT BOARD . . . . . 6

5. WIRE THE THERMOSTAT TO THE

HVAC EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . 8 Diagram 1 – Single-Stage Furnace and AC . . . . . . 9 Diagram 2 – Two-Stage Furnace and AC . . . . . . . 10 Diagram 3 – Two-Stage Roof Top Unit . . . . . . . . 11

PAGE

Diagram 4 – Boiler with AC . . . . . . . . . . . . . . . . . 12

Diagram 5 – Radiant Floor 1st Stage Heat

with Furnace 2nd Stage Heat and AC . . . . . . . . . 13

Diagram 6 – Single-Stage Heat Pump with Single-Stage Back Up Heat . . . . . . . . . . . . . . . . . 14

Diagram 7 – Single-Stage Heat Pump with Two-Stage Back Up Heat . . . . . . . . . . . . . . . . . . . 15

Diagram 8 – Two-Stage Heat Pump . . . . . . . . . . . 16

6. OPTIONAL – WIRE THE EVENT

TRIGGERED OUTPUT (ETO) . . . . . . . . . . . . . . . 17

7. OPTIONAL – INSTALL AN OUTDOOR TEMPERATURE SENSOR . . . . . . . . . . . . . . . . . . 19

8. OPTIONAL – INSTALL AN AUTOMATIC DIGITAL HUMIDIFIER CONTROL (ADHC) . . . . 22

PAGE

9. OPTIONAL – INSTALL AN INDOOR TEMPERATURE SENSOR . . . . . . . . . . . . . . . . . . 24

10. THERMOSTAT STARTUP . . . . . . . . . . . . . . . . . 26

Thermostat Set Up . . . . . . . . . . . . . . . . . . . . . . . . 27

– Heat Only, Cool Only . . . . . . . . . . . . . . . . . . . . . .27

– Number of Auxiliary Heat Stages . . . . . . . . . . .27

Verify Outdoor Temperature Sensor . . . . . . . . . . . 27

Check Fan Operation . . . . . . . . . . . . . . . . . . . . . . . 28

Verify ADHC Connection . . . . . . . . . . . . . . . . . . . . 28

Check Heating Operation . . . . . . . . . . . . . . . . . . . 30

Check Cooling Operation . . . . . . . . . . . . . . . . . . . 32

Check Emergency Heat Operation

(Heat Pumps Only) . . . . . . . . . . . . . . . . . . . . . . . . 34

PAGE

11. CUSTOMIZE THE

APPLICATION SETTINGS . . . . . . . . . . . . . . . . 36 Programmable or Non-Programmable . . . . . . . . 36 Differentials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Offset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Deadband . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Progressive Recovery . . . . . . . . . . . . . . . . . . . . . 39 Balance Points (Heat Pumps Only) . . . . . . . . . . . 40 Input Dealer Contact Information . . . . . . . . . . . . 41 Blower Extension for Humidity Control . . . . . . . 42

Monitors – Air Filter, Service Humidifier,

UV Lamp, Service HVAC . . . . . . . . . . . . . . . . . . . 43

Image 2
Contents Safety & Installation Instructions Table of Contents Safety Instructions Model 8570 SpecificationsWire Requirements Open the Thermostat Mount the Thermostat Base to the WallSet to HP when installed with heat pumps Single Multi Elect GASWire the Thermostat to the Hvac Equipment Run a cable with the correct number of wiresAprilaire Model Diagram 4 Boiler with AC Diagram 7 Single-Stage Heat Pump with Two-Stage Load Optional Wire the Event Triggered Output ETOTurn it off when unoccupied NORTH, East Settings MenuProgrammable Output Or West Side117.6 230.6163.8 85.4Mount the Adhc and its outdoor temperature sensor ThermostatMount the indoor temperature sensor Auxiliary Heat Setup Control SET UPThermostat SET UP SET Number of Auxiliary Heat Stages Thermostat Startup Stand Alone ApplicationsCheck FAN Operation Check Heating Operation To Cool and make a call for cooling Check Cooling OperationThermostat does not call for cooling MultiRegardless of how these are set To Emergency Heat and make a call for heatSingle/Multi Same outputs come on GasCustomize the Application Settings Offset To go back a character, press the Back button ADV. Settings MenuRange is -10F to 35F and OFF Press the Call Dealer button Press the Reset button Press the Menu buttonBOX 1467 MADISON,WI
Related manuals
Manual 40 pages 49.36 Kb